Content |
The MP-032B is designed to provide aural and visual monitoring for the outputs of up to 10 power amplifiers. It includes a 5" monitor speaker, a volume control, a watt meter, and a 11-position (OFF and 10 channels) selector switch. The unit also furnished with a line voltage selector on the rear panel to allow monitoring of 25, 50, 70, and 100-volt line outputs.
Features: - Monitoring up to 10 channels.
- Aural and visual monitoring.
- Compact, space-saving construction.
- VU meter.
- Monitors 25 V, 50 V, 70 V and 100 V speaker line signals.
- Internal speaker with selector switch.
- Black finish to match 900 Series.
- Five year manufacturers warranty.
|
Five attenuation settings (OFF, 0/-6/-12/ -16dB), over an input range from 0.5W to 30W. |
The RM-300MF Fireman's Microphone is designed for exclusive use with the VM-3000 Series. It is equipped with an emergency activation key, permitting pre-recorded evacuation and alert announcements to be activated, and microphone announcement to be made in emergency situations. By connecting the RM-320F Fireman's Microphone Extension to the RM-300MF, the number of function keys can be expanded. The zone selection or failure acknowledgment function can be assigned to such function keys.
Power Source | 24 V DC (operating range: 15 - 40 V DC, supplied from the VM-3000 system) | Current Consumption | 120 mA (RM-300MF), 660 mA (with 3 RM-320F connected) | Frequency Response | 200 Hz - 15 kHz | Distortion | 1 % or less | S/N Ratio | 55 dB or more | Microphone | Unidirectional dynamic microphone with talk key, compressor (on/off switchable) | Volume Control | Microphone volume control, Buzzer volume control | Connection Cable | Main line: Shield CPEV cable (each one pair of Audio line, Data line, Power supply line)
or Category 5 Shielded Twisted-Pair straight cable for LAN (CAT5-STP), M3 screw terminal | Maximum Cable Distance | Total 800 m (874.89 yd) | No. of Connectable RM-320F | Max. 3 units | Operation | Emergency key, Evacuate key, Alert key, Emergency reset key, CPU switch, Reset switch | Indicator | Power indicator, Emergency indicator, Communication failure indicator, CPU OFF indicator,
Evacuation announcement indicator, Alert announcement indicator,
Emergency reset indicator, Microphone in-use indicator,
Emergency broadcast equipment in-use indicator | Operating Temperature | -5 ℃ to +45 ℃ (23 ゜F to 113 ゜F) | Operating Humidity | 5 % to 95 %RH (no condensation) | Finish | ABS resin, blueish gray (PANTONE 538 or its equivalent) | Dimensions | 200 (W) × 215 (H) × 82.5 (D) mm (7.87" × 8.46" × 3.25“) | Weight | 1.1 kg (2.43 lb) (with wall mounting bracket unit) | Accessory | Wall mounting bracket unit …1, Wall mounting screw …2 |
|
The RM-210 is an extension unit for increasing the number of function keys of TOA's RM-200M, RM-200XF and RM-200X Remote Microphones.
Specification |
| Current Consumption | 20mA max. (in terms of RM-200M's DC power input 75mA max. (interms of DC power inputs of RM-200X and RM-200XF) | Connection | Connection to RM-200M, RM-200X or RM-200XF by way of dedicated Cable | Number of Function | Keys 10 | Function | When used to expand the RM-200M:
Selects and activates the Voice Announcement Board messages.
When used to expand the RM-200X and RM-200XF (PC software setting):
Emergency activation, emergency reset, BGM pattern selection, EV message activation, broadcast zone selection, monitor zone selection, chime activation, Talk switch activation, control output activation, input volume adjustment, zone volume adjustment, and failure output indication and reset. | Finish | ABS resin, bluish gray (PANTON 538 or its equivalent) | Dimensions | 110 (W) x 76.5 (H) x 215 (D)mm | Weight | 350g | Accessory | Extension cable x 1, Linkage bracket A x 1, Linkage bracket B x 1, Screw for linkage bracket x 12 |
|
toa-at-100upr Build-in Attenuator with Relay
Toa - 100V installation
Build-in Attenuator with Relay 100 W / 100 V
|
RM-200M - Five/ten zone console for VM-2120/2240 amplfiers
The RM-200M Remote Microphone that allows announcements to be made to any speaker zone and emergency announcements to all zones on a system with the VM-2120/2240 system management amplifiers.
These announcements can be made live or pre-recorded announcements
can be activated. The remote microphone is connected by cable to the
RM-210 Remote Microphone Extension unit.
SPECIFICATIONS:
Power Requirement | 24 V DC (12-30 V DC), (Supplied from VM-2120/VM-2240 Amplifier or local power suppy.) | Distortion | Less than 1% | Frequency Response | 100 - 10,000 Hz | Distortion | Less than 1% | Signal-to-Noise Ratio | More than 60 dB | Audio Output | 0 dB*1, 600 O, balanced | Microphone | Unidirectional electret condenser microphone, gooseneck type. | Speaker Zone Control | Zones 1-5 (Zones 1-10 with 2 stacked amplifiers) Groups 1-2, and All-Zone Broadcast | Emergency Broadcast | Activation of Emergency Broadcast (pre-recorded announcement*2 or live microphone announcement) by Emergency Switch | Voice Announcement Board Control | Activation of 5 messages*2 | Number of Connectable Units | Up to 4 | Communication System | RS-485 | Volume Control | Microphone volume control | Connection Cable and Connector Category | 5 STP cable, RJ45 connector | Communication Distance | 800 m maximum in total | Finish | ABS resin | Dimensions | 190 (W) × 75.7 (H) × 21.5 (D) mm (Gooseneck microphone excluded) |
| *1 0 dB = 1 V
*2 An optional EV-200 Board must be mounted in the VM-2120 or VM-2240 Amplifier. |
|