Content | This new mic is a performance / price breakthrough. It has an acoustically identical version of the legendary CK1 capsule that is permanently mounted. This combination can handle high output transients as well as subtle harmonics. Also included are switchable 75 and 150Hz 12dB per octave rolloff, and switchable -10 & -20 dB input pad. It is a single pattern (cardioid), and has a frequency response of 20 to 20kHz with 135 dB SPL. Requires 12 to 48V phantom power. Kit comes with bag, windscreen and clip.
For more than twenty years, the AKG C 451 with the CK 1 condenser capsule was a standard item on tour riders for sound companies and required by leading engineers for studio projects. When it was discontinued in 1993, there was still a big demand for this microphone. AKG now has an updated version of this classic microphone.
The new C 451B provides the same frequency response as the legendary CK 1 with the same slight high-end rise that was the signature of the original. This characteristic makes the C 451B an ideal tool for capturing signals rich in transients such as acoustic guitars, snare drums, hi-hats and for overhead micing of drum kits. The C 451B?s response eliminates the need for heavy EQ on these instruments.
The new C 451B has also benefited from newer electronic technology with machine soldering and surface-mount components that improve noise performance and make the microphone much more reliable than the original.
Other special features include switchable 10 dB and 20 dB preattenuation pads and switchable low cut filters at 75 Hz or 150 Hz. Standard accessories included are an SA 40 stand adaptor, W 90 windscreen and a rugged zippered bag. Each C 451B also comes with an individual frequency response printout.
Three-year warranty.
Specification
Polar pattern: cardioid
Frequency range: 20?20,000 Hz
Sensitivity: 9 mV/Pa (-41 dBV re 1 V/Pa)
Max. SPL for 0.5 % THD: 135/145/155 dB SPL (-0/-10/-20 dB)
Equivalent noise level: 18 dB-A to DIN 45 412
Signal/noise ratio (A-weighted): 76 dB
Preattenuation pad: switchable, 0, -10,-20 dB Bass cut filter: switchable to flat or 12 dB/octave at 75 Hz or 150 Hz
Electrical impedance: Recommended load impedance: >1.000 Ohms
Power requirement: 9?52 Volt phantom power to DIN 45 596/IEC 268-15
Current consumption: Connector: 3-pin male XLR
Finish: satin nickel plated
Size: dia.: 190 mm (0.7 in.); length: 160 mm (6.3 in.)
Net/shipping weight: 125/760 g (4.4 oz./1.7 lbs.)
Standard accessories: W 90 windscreen, SA 40 stand adapter |
C 568 B
Compact, short shotgun microphone
Integrated, switchable bass cut filter minimizes mechanical noise
Operates on phantom power
High directivity and wide frequency response in a relatively short shotgun make this
microphone a perfect tool for theater, sound reinforcement, and film/TV applications.
Due to its compact and lightweight design, the C 568 B is ideal for camera mount
applications. Below 500 Hz it functions as a hypercardioid microphone; above 500 Hz
the acoustic interference tube introduces increasing directivity. A switchable 12 dB/
octave 120 Hz bass cut filter effectively suppresses rumble and wind noise. The rugged,
all-metal body contains the built-in preamp. Phantom powering (9?52 V) required; foam
windscreen and stand adapter included.
SPECIFICATIONS:
Polar pattern hypercardioid/directional
Frequency range 20 to 20,000 Hz
Sensitivity 11 mV/Pa (-39 dBV)
Max. SPL 128 dB
Equivalent noise level (CCIR 468-3) 29 dB
Equivalent noise level 18 dB-A
Signal/noise ratio 76 dB
Bass filter 12 dB/octave at 120 Hz
Impedance 600 ohms
Recommended load impedance >2000 ohms
Supply voltage 9 to 52 V phantom power to DIN 45596
Current consumption |
Back-electret Microphone Capsule suitable for K6 and K6P Powering Modules. The ME 64 is a cardioid microphone capsule designed for use with the K6 and K6P powering modules. It has a very wide range of applications including reporting, interviews, dubbing, live sound reinforcement and recording applications. Matte black, anodized, scratch-resistant finish.
Features
Excellent directivity across whole frequency range
Very good feedback rejection
Effective rejection of incidental rear noise
High speech clarity
High maximum sound pressure level
Wide frequency range
Integrated pop filter
|
The ME 65 is a super-cardioid microphone head designed for use with the K6 and K6P powering modules. It is especially suited to vocal and speech applications. Matt black, anodised, scratch-resistant finish.
- Pick-up pattern : super-cardioid
- Sensitivity in free field, no load (1kHz) : 10 mV/Pa +- 2,5 dB
- Nominal impedance : 200 Ohm (K6)
- Min. terminating impedance : 1000 Ohm (K6)
- Equivalent noise level : 20 dB
- Dimensions : d 44 x 131 mm
-
Weight :
|
The Stereo wonder. The new NT4, a visually striking microphone that solves
the age-old problem of stereo recording by eliminating the need to purchase
matched pairs and the associated complex set-up bars and adaptors to get
professional results. With a fixed 90 Deg. X/Y configuration and perfectly
matched stereo condenser capsules, the NT4 lets you record any source with
immaculate stereo detail.
The NT4 has a 128 dB dynamic range, 143 dBA SPL and low self-noise. Offering
selectable battery or phantom power operation with power indicator light, the NT4
is ideally suited to both studio and location recording.
The NT4 comes supplied in a custom carry case with a windshield, XLR to mini-jack
and dual XLR cables for portable DAT or professional balanced input connection.
SPECIFICATIONS:
Acoustic principle:
Stereo Microphone. 90° XY placement. Each side comprises an
externally polarised single diaphragm condenser transducer
Directional pattern: Cardioid per capsule
Frequency range: 20Hz - 20kHz
Output impedance: 200? per side
Signal noise ratio din iec 651: 78dB
Equvalent noise:128 dB
Power supply voltage:
P48 (38V?52V), P24 (20V-26V), P12 (10.8V-13.2V), 9V battery
Current consumption: 4 mA, 2 mA, 2.8 mA, 2.4mA
Weight without battery: 480g
Weight with battery: 2.3kg
|
The e 865 is a fully professional super-cardioid vocal microphone utilising the very best in condenser microphone technology to achieve new standards of quality and sound. The microphone capsule insorporates special blast/pop protiction plate to shield the diaphragm from excessive sound pressure levels. ON/OFF Switch.
- Pick-up pattern : super cardioid
- Sensitivity in free field, no load : (1kHz) 3 mV/Pa
- Max. Sound pressure level (aktiv) : 150 dB
- Nominal impedance : 200 Ohm
- Min. terminating impedance : 1000 Ohm
- Dimensions : d 47 x 193 mm
- Weight : w/o cable 311 g
- Frequency response (microphone) : 40.....20000 Hz
- Phantom powering : 12 - 48 V
|