Content |
Multicore Studio Balanced, insulated in pairs + overall shielding Storm MCF in 8, 12, 16, 20, 24, 32, 40 and 48 pairs version Order Code: KSC 08 = 8 pair KSC 12 = 12 pair KSC 16 = 16 pair KSC 20 = 20 pair KSC 24 = 24 pair KSC 32 = 32 pair KSC 40 = 40 pair KSC 48 = 48 pair Colour: Black The Storm MCF offers PVC insulation in pairs, common in studiocores. All pairs are wear-resistant number coded as well as colour coding in multiples of eight. Each pair has a pre-twisted drain wire and additional AL/PT foil shielding for protection against corrosion and oxidisation. Conductors and drain wire are tin plated. Product advantages ? Very flexible and durable through the use of the rubber like jacket material. ? Simple and fast to work through the use of compound foil and a pre-twisted filler strand. ? High bending cycles ? High transmission quality even for longer lengths (low capacity). Application ? Ideal for studio installation and touring ? Fixed installations in theatres, public buildings, etc. Technical Data Construction:: {xx(2LI2Y0,22mm2)(ST)Y}F(ST)Y No. of conductors: 2 x 0,22 mm2 (AWG24) Copper strand per conductor: 7 x 0,20 mm Conductor insulation: PE 1,22 mm Shielding: AL/PT-foil + overall shield. copper braiding Shielding factor: 100% Temperature range: ?30°C...+70°C Weight per 1 m: upon request Jacket Colour: black Packaging: per m Electrical Data Capac.cond./cond. per 1 m: 65 pF Capac. cond./shield. per 1 m: 130 pF Cond. resistance per 1 km: < 80 Ohm Shielding resistance per 1 km: 75 Ohm Insulation resistance per 1 km: > 1 GOhm Surge impedance: 85 Ohm |
Adam Hall KSC16 Multicore cable 16 pair studio with numbercode, black
All pairs are wear-resistant number coded as well as colour coding in multiples of eight. each pair has a pre-twisted drain wire and additional AL/PT foil shielding for protection against corrosion and oxidisation. Conductors and drain wire are tin plated. | Adam Hall Cables 4 STAR HPA 325 Hybrid Cable Power & Audio 3 x 2.5 mm² & 2 x 0.22 mm². Price per meter
General
Type
Power / Signal Cable
Temperature range
-20 - 70 °C
Power
Number of internal conductors
3
Center conductor cross section
2.5 mm²
Center conductor construction
96 x 0.10 mm
Center conductor material
OFC
Audio
Number of inner conductors 2
2
Center conductor cross section 2
0.22 mm²
Center conductor construction 2
28 x 0.10 mm
Center conductor material 2
OFC
Conductor resistance 2
55 ohm/km
|
A P P L I C A T I O N Analogue audio Fixed installations Audio transmissions in noisy environment Wiring in professional sound studios P R O D U C T A D V A N T A G E S Very good protection against electromagnetique interferences thanks to individually shielded pairs and overall shield T E C H N I C A L D A T A NO. OF CONDUCTORS: No. x 2 x 0,22 mm2 Tinned copper CONDUCTOR INSULATION: PE SHIELDING BY PAIR: Aluminium polyester foil + drain wire COLOR OF CONDUCTEUR: White / blue COLOR OF PAIR: By number OVERALLSHIELD: Aluminium polyester foil + drain wire JACKET: Black PVC PACKAGING: Per m SUITABLE PLUG: XLR, jacks PRICE PER METER
|
24 AWG stranded (7x32) TC conductor, polyolefin insulation, individually shielded Beldfoil? (100% coverage) numbered/color-coded PVC jackets, jackets and shields bonded to strip simultaneously, overall Beldfoil shield and 24 AWG TC drain wire. PHYSICAL CHARACTERISTICS :
CONDUCTOR : Number of Pairs: 12 Total Number of Conductors: 24 AWG: 24 Stranding: 7x32 Conductor Diameter: .024 in. Conductor Material: TC - Tinned Copper INSULATION : Insulation Material: PO - Polyolefin Nom. Insulation Wall Thickness: .008 in. Insulation Diameter: .040 in. Lay Length: 1.75 in. Twists/ft.: 6.85 Pair Color Code Chart: Red & Black INNER SHIELD : Inner Shield Material Trade Name: Beldfoil? Inner Shield Type: Tape Inner Shield Material: Aluminum Foil-Polyester Tape Inner Shield % Coverage: 100 % Inner Shield Drain Wire AWG: 24 Inner Shield Drain Wire Stranding: 7x32 Inner Shield Drain Wire Conductor Material: TC - Tinned Copper INNER JACKET : Inner Jacket Material: PVC - Polyvinyl Chloride Inner Jacket Nominal Wall Thickness: .014 in. Inner Jacket Diameter: .111 in. Inner Jacket Color Code Chart: Number Color 1 Brown 2 Red 3 Orange 4 Yellow 5 Green 6 Blue 7 Purple Number Color 8 Gray 9 White 10 Black 11 Tan 12 Pink OUTER SHIELD : Outer Shield Material Trade Name: Beldfoil? Outer Shield Type: Tape Outer Shield Material: Aluminum Foil-Polyester Tape Outer Shield %Coverage: 100 % OUTER SHIELD DRAIN WIRE : Outer Shield Drain Wire AWG: 18 Outer Shield Drain Wire Stranding: 7x26 Outer Shield Drain Wire Conductor Material: TC - Tinned Copper OUTER JACKET : Outer Jacket Material: PVC - Polyvinyl Chloride Outer Jacket Nominal Wall Thickness: .045 in. Outer Jacket Ripcord: Yes OVERALL NOMINAL DIAMETER : Overall Nominal Diameter: .561 in. MECHANICAL CHARACTERISTICS : Operating Temperature Range: -35°C To +75°C Bulk Cable Weight: 128.4 lbs/1000 ft. Max. Recommended Pulling Tension: 220.4 lbs. Min. Bend Radius (Install): 5.5 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE : APPLICABLE STANDARDS : NEC/(UL) Specification: CM CEC/C(UL) Specification: CM EU CE Mark (Y/N): Yes EU RoHS Compliant (Y/N): Yes EU RoHS Compliance Date (mm/dd/yyyy):: 01/01/2004 PLENUM/NON-PLENUM : Plenum (Y/N): N
ELECTRICAL CHARACTERISTICS : Nom. Characteristic Impedance: 50 Ω Nom. Inductance: .18 ?H/ft Nom. Capacitance Conductor to Conductor @ 1 KHz: 31 pF/ft Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz: 58 pF/ft Nominal Velocity of Propagation: 66 % Nom. Conductor DC Resistance @ 20 Deg. C: 23.3 Ω/1000 ft Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 15.9 Ω/1000 ft Max. Operating Voltage - UL: 300 V RMS Max. Recommended Current: 1.05 Amps per conductor @ 25°C
NOTES : Notes: Jacket and shield are bonded so both can be removed with automatic stripping equipment. Beldfoil? provides high reliability with ease of termination. NOTE:Price per meter |
24 AWG stranded (7x32) TC conductor, polyolefin insulation, individually shielded Beldfoil?
(100% coverage) numbered/color-coded PVC jackets, jackets and shields bonded to strip
simultaneously, overall Beldfoil shield and 24 AWG TC drain wire.
PHYSICAL CHARACTERISTICS :
CONDUCTOR :
Number of Pairs: 8
Total Number of Conductors: 16
AWG: 24
Stranding: 7x32
Conductor Diameter: .024 in.
Conductor Material: TC - Tinned Copper
INSULATION :
Insulation Material: PO - Polyolefin
Nom. Insulation Wall Thickness: .008 in.
Insulation Diameter: .040 in.
Lay Length: 1.75 in.
Twists/ft.: 6.85
Pair Color Code Chart: Red & Black
INNER SHIELD :
Inner Shield Material Trade Name: Beldfoil?
Inner Shield Type: Tape
Inner Shield Material: Aluminum Foil-Polyester Tape
Inner Shield % Coverage: 100 %
Inner Shield Drain Wire AWG: 24
Inner Shield Drain Wire Stranding: 7x32
Inner Shield Drain Wire Conductor Material: TC - Tinned Copper
INNER JACKET :
Inner Jacket Material: PVC - Polyvinyl Chloride
Inner Jacket Nominal Wall Thickness: .014 in.
Inner Jacket Diameter: .111 in.
OVERALL CABLING : Overall Cabling Color Code Chart:
Number Color
1 Brown
2 Red
3 Orange
4 Yellow
5 Green
6 Blue
7 Purple
8 Gray
OUTER SHIELD :
Outer Shield Material Trade Name: Beldfoil?
Outer Shield Type: Tape
Outer Shield Material: Aluminum Foil-Polyester Tape
Outer Shield %Coverage: 100 %
OUTER SHIELD DRAIN WIRE :
Outer Shield Drain Wire AWG: 18
Outer Shield Drain Wire Stranding: 7x26
Outer Shield Drain Wire Conductor Material: TC - Tinned Copper
OUTER JACKET :
Outer Jacket Material: PVC - Polyvinyl Chloride
Outer Jacket Nominal Wall Thickness: .033 in.
Outer Jacket Ripcord: Yes
OVERALL NOMINAL DIAMETER :
Overall Nominal Diameter: .452 in.
MECHANICAL CHARACTERISTICS :
Operating Temperature Range: -35°C To +75°C
Bulk Cable Weight: 103.5 lbs/1000 ft.
Max. Recommended Pulling Tension: 152 lbs.
Min. Bend Radius (Install): 4.5 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE :
APPLICABLE STANDARDS :
NEC/(UL) Specification: CM
CEC/C(UL) Specification: CM
EU CE Mark (Y/N): Yes
EU RoHS Compliant (Y/N): Yes
EU RoHS Compliance Date (mm/dd/yyyy):: 01/01/2004
PLENUM/NON-PLENUM :
Plenum (Y/N): N
ELECTRICAL CHARACTERISTICS :
Nom. Inductance: .18 ?H/ft
Nom. Capacitance Conductor to Conductor @ 1 KHz: 31 pF/ft
Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz: 58 pF/ft
Nominal Velocity of Propagation: 66 %
Nom. Conductor DC Resistance @ 20 Deg. C: 23.3 Ω/1000 ft
Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 15.9 Ω/1000 ft
Max. Operating Voltage - UL: 300 V RMS
Max. Recommended Current: 1.05 Amps per conductor @ 25°C
NOTE:Price per meter
|
Reviews
There are no reviews yet.