Content | The Apart MDS microphone discussion system is a highly flexible small to medium size tabletop discussion system. This easy to set up and to easy to use audio system is the perfect solution for meeting rooms, board rooms and medium conference rooms. This discussion system consists of a chairman unit (MDS.CHAIR) and up to 19 delegate units (MDS.DEL). The connection interface (MDS.INT) is located at the beginning of the microphone chain.
This MDS system has a unique circuit loop design with an easy set-up using standard CAT5 cables for linking up to 20 units in a daisy chain (every microphone and switching adaptor can be located anywhere in the loop). When the chairman presses the mute button, only the chairman unit will be active and all delegates will be muted and deactivated. The delegates can press a button to talk into the flexible gooseneck microphone (no mute function). |
- System Features and Outline
- Operations such as giving speech permission can be done from the operation PC. *Custom design.
- The number of conference units can be set for any of one, two or four persons allowed to talk at a time.
- All speeches during the conference can be recorded clearly.
- Sub audio(Japanese interpretation) is not recorded.
- Threefold choice vote function enables the voting just at the press of a Vote key on each unit. The result can be instantly totalized on the Central unit.
- Speeches can be addressed to audience via sound amplification. * The sub audio output is not amplified
SPECIFICATION:
Power Source | 100-240 V AC, 50/60Hz (supplied from AC adapter (accessory)) | Power Consumption | 72W | Input | MIC: -60 dB*, 600O,unbalanced, phone jackAUX: -20 dB*, 10 kO,unbalanced, phone jack | Output | REC: -20 dB*, 10 kΩ, unbalanced, phone jack, RCA pin jack HEADPHONE: Mini jack | Number of Connectable Chairman/Delegate Units | 64 units | Number of Connectable Infrared Transmitter/Receiver Units | 4 units (up to 16 units by using four Distributors) | Infrared Transmitter/Receiver I/O Terminal | 4 BNC jacks | External Control Terminal | D-sub connector (9 P, male) | LED Indicator | Audio signal receiving indicators 1-4 CH,Data signal receiving indicator, External control priority indicator, External control communication indicator, Power indicator, Battery indicator (flashes when a Chairman/Delegate unit's battery nears complete discharge) | Function Switch | Simultaneous speaker No. setting switch: 1/2/4 Mic-off setting switch: TIME OUT ON/OFF
Speech priority selector switch: A/B/C (A: First-in-first-out priority, B: Last-in-first-out priority, C: Fixed for the first unit, and last-in-first-out for the subsequent units) | Operating Temperature | 0º to+40º | Finish | Panel: Surface-treated steel plate, gray metallic, paint, semi-gloss | Weight | 2.7kg | Accessory | AC adapter (Cord length: 1.8 m DC cord, and 2 m detachable AC cord)…1 | Option | Rack mounting bracket: MB-TS900 | | *0dB=1V |
|
Power (w/o IEC power cord) for up to 40 microphone units. |
- System Features and Outline
- Bilingual conference system. Either English interpretation (main audio) or Japanese interpretation (sub audio) is selectable for monitoring.
- Operations such as giving speech permission can be done from the operation PC. *Custom design.
- The number of conference units can be set for any of one, two or four persons allowed to talk at a time.
- All speeches during the conference can be recorded clearly.
- Sub audio(Japanese interpretation) is not recorded.
- Threefold choice vote function enables the voting just at the press of a Vote key on each unit. The result can be instantly totalized on the Central unit.
- Speeches can be addressed to audience via sound amplification. * The sub audio output is not amplified
SPECIFICATION:
Power Source | 7.4 V DC (battery), 9 V DC (AC adapter) (supplied from BP-900 battery (option) or AD-0910 AC adapter (option)) | Power Consumption | MAX. 270 mA | Infrared Emitter/Detector Wavelength | 870 nm (AM: Brightness modulation) | Infrared Emitter/Detector Modulation Method | Frequency modulation | Infrared Emitter/Detector Carrier Frequency | Transmission: Audio channel 1: 7.35 MHzAudio channel 2: 8.10 MHzAudio channel 3: 8.55 MHzAudio channel 4: 9.15 MHzControl channel: 6.45 MHz | | Reception: Audio channel: 1.95 MHz | Infrared Emitter/Detector Acceptance Angle | Vertical: 90°, Horizontal: 120° | Infrared Emitter/Detector Emission Angle | Vertical: 90°, Horizontal: 120° | Infrared Emitter/Detector Covering Range | 7 m (radius) | Input | Microphone terminal: Combined type of XLR-4-31 (dedicated for connecting the optional TS-903 or TS-904) | LED Indicator(TS-801·802) | Speech indicator (flashes when the unit is out of communications range), Power indicator (flashes when the unit is out of communications range or when the battery level is low) | Battery Life | Approx. 10 hours (when the fully-charged BP-900 battery is used with "During Speech" to "Standby" ratio of 1:2) | Operating Temperature | 0.to+40. | Dimensions | 210(W )×65.9(H )×152(D )mm | Weight | 630g | Option | Microphone: TS-903, TS-904 (Select either one.)Lithium-ion battery: BP-900 AC adapter: AD-0910 |
| Infrared radiator for use with TS-800. It comes with wall mount and stand in microphone crane. Coverage area within 7 meters in sight. Power supply via the central unit. Maximum number in each system 16 pcs. |
AKG Conference System CS 2 is fully modular and therefore highly flexible, allowing users to create a custom system for any conference application. From microphone capsules to power supplies, designers will find exactly the right components for every type of conference system. Analog control is provided by the Base Station. |
Reviews
There are no reviews yet.