Content |
| - IT CAN CHECK SPEAKER WIRE OPEN, SHORT, AND EXCEED VALUE ACCORDING TO SETTING UP IMPEDANCE. - IT AUTOMATICALLY CHECKS SPEAKER WIRES BY PROGRAM TIMER OPERATIONS. THE POSSIBLE SET UP TIMES ARE BETWEEN 20 MINUTES AND 200 MINUTES. - RS-232C TERMINAL IN/OUT CONTROL WITH AMX/CRESTRON INTERFACE. - DC 24V OPERATION. - COMPACT DESIGN 2RU(3.5”). - KEEPS STORED VALUES BY NON VOLATILE MEMORY - ALERT SOUNDS WHEN FAULT IS FOUND - BUZZER ON/OFF FUNCTION. | | | | | SC - 624 | Power source | 24VDC | Power Consumption | 300mA | Weight | 5.2Kg / 11.5lb | Dimensions (WxHxD) | 1482 x 88 x380mm /19 x 3.5 x 15in | | | |
|
Volume Control 12W with priority.
|
*Convenient Priority Broadcasting
*Convenient Installation and Construction without ID Setting
*RS-422 Communication between RM-500 and Z-500
*21 Zone Paging Selection
*Output Signal Level Display
*Multi Chime Options
*Weight: 1.6kg/3.5Ib
*DImensions(W×H×D): 200×206×70mm/7.9×8.1×2.8in
|
- PRIORITY CONTROL It controls the priority of emergency, timer, remote1, remote2, main(normal). - AUTO FIRE SENSOR The fire alarm will be given automatically to the designated areas by detecting fire sensor input. - SPEAKER SWITCHING ON EMERGENCY OR NORMAL(MAIN) You can control the speaker relay on emergency or normal(main) mode by using the speaker switch on front panel. - DISPLAY STATUS You can easily check the priority status. - 2 AND 3 WIRE SPEAKER LINE SYSTEM You can control the speaker line on the 2 wire system or 3 wire system. - EXTENSION FUNCTION You can easily expand by connecting additional ECS-616.
ECS-616 | Priority Control | Emergency >Timer > Remote1 > Remote2 > Main | Link in/ out Interface | RS-422(19200bps,Data 8bits,Stop 1bit, Non Parity bit, Start1bit) | Link in/ out interface Distance | 1.2 km | Operation Temperature | -10 °C ~+ 40 °C | Power Source | 24V DC | Power Consumption | 900mA | Weight | 4.8Kg/10.6Ib | Dimensions( W x H x D) | 482(W)x 88(H) x 380(D) mm / 19(W)x 3.5(H)x 15(D)in | ※ Specifications and design subject to change without notice. |
|
The RM-300MF Fireman's Microphone is designed for exclusive use with the VM-3000 Series. It is equipped with an emergency activation key, permitting pre-recorded evacuation and alert announcements to be activated, and microphone announcement to be made in emergency situations. By connecting the RM-320F Fireman's Microphone Extension to the RM-300MF, the number of function keys can be expanded. The zone selection or failure acknowledgment function can be assigned to such function keys.
Power Source
|
24 V DC (operating range: 15 - 40 V DC, supplied from the VM-3000 system)
|
Current Consumption
|
120 mA (RM-300MF), 660 mA (with 3 RM-320F connected)
|
Frequency Response
|
200 Hz - 15 kHz
|
Distortion
|
1 % or less
|
S/N Ratio
|
55 dB or more
|
Microphone
|
Unidirectional dynamic microphone with talk key, compressor (on/off switchable)
|
Volume Control
|
Microphone volume control, Buzzer volume control
|
Connection Cable
|
Main line: Shield CPEV cable (each one pair of Audio line, Data line, Power supply line)
or Category 5 Shielded Twisted-Pair straight cable for LAN (CAT5-STP), M3 screw terminal
|
Maximum Cable Distance
|
Total 800 m (874.89 yd)
|
No. of Connectable RM-320F
|
Max. 3 units
|
Operation
|
Emergency key, Evacuate key, Alert key, Emergency reset key, CPU switch, Reset switch
|
Indicator
|
Power indicator, Emergency indicator, Communication failure indicator, CPU OFF indicator,
Evacuation announcement indicator, Alert announcement indicator,
Emergency reset indicator, Microphone in-use indicator,
Emergency broadcast equipment in-use indicator
|
Operating Temperature
|
-5 ℃ to +45 ℃ (23 ゜F to 113 ゜F)
|
Operating Humidity
|
5 % to 95 %RH (no condensation)
|
Finish
|
ABS resin, blueish gray (PANTONE 538 or its equivalent)
|
Dimensions
|
200 (W) × 215 (H) × 82.5 (D) mm (7.87" × 8.46" × 3.25“)
|
Weight
|
1.1 kg (2.43 lb) (with wall mounting bracket unit)
|
Accessory
|
Wall mounting bracket unit…1, Wall mounting screw…2
|
|
- CONSIDERATION OF USERʼS CONVENIENCE NUMERIC buttons and various function buttons are separated for timer program enter and convenience in use so that the user can easily operate. - ADOPTION OF VACUUM FLUORESCENT DISPLAY PANEL Adopting a vacuum fluorescent display of a dot matrix method enables to check operation status of each function at a glimpse. - PROGRAMMING USING A PC You can easily execute reservation setting thorough management program by connecting a PC to the RS-232C port. - VARIOUS MELODY AND SOUND OUTPUT You can generate various melodies and sounds by linking the flash memory mounted on this unit to our model, PV-632 (MULTI-VOICE FILE). - AC POWER OUTPUT CONTROL When PW-642 and other equipment are connected via the AC outlet terminal of PW-642, you can turn ON/OFF the AC outlet button in the front panel and manually control ON/OFF of the AC power connected to other device. - BACK-UP POWER You can continue to maintain the time counter for about a week though the inner back-up even though AC power turns off with current time set. There is no need of readjusting time even though AC power is applied. - MEASURE AGAINST POWER FAILURE A separate memory is used to prevent data extinguishment due to power failure or other unstable power. - AUTOMATIC RETURN In programming data using a key button on the front side of PW-642 without using a PC, no pressing any button is recognized as cancel of program entry to return to normal operation status. - AC POWER OUTPUT TIME ADJUSTMENT You can adjust the AC power output time of PW-642 by 1~20sec to prevent time delay from occurring in the interface with the outside power amp. - KEY LOCK You can protect reservations and userʼs setting. |
|
|
| | PW - 642 | Input Channel (Balanced) | 5CH | Output Channel (Balanced) | 4CH | Output Level | Maximum 1v | AC Power Output 1 | Maximum 500W | AC Power Output 2 | Maximum 30 w | Data Preservation Time | 7 days and more | Melody Time (15 settings total - 247 seconds) | No.1 | 2 seconds | No.2 | 3 Seconds | No.3 | 3 Seconds | No.4 | 5 Seconds | No.5 | 5 Seconds | No.6 | 7 Seconds | No.7 | 7 Seconds | No.8 | 10 Seconds | No.9 | 10 Seconds | No.10 | 15 Seconds | No.11 | 20 Seconds | No.12 | 30 Seconds | No.13 | 30 Seconds | No.14 | 40 Seconds | No15 | 60 Seconds | Operation Temperature | -10°C ~+ 40°C | Power Source | 100- 120 VAC or 220 -240VAC; 50/60 Hz (Supplied AC mains transformer depends on country requirements) | Power Consumption | 10W | Weight(SET) | 5.7Kg/12.6Ib | Dimension(SET) | 482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in | ※ Specifications and design subject to change without notice. | | | |
|
Reviews
There are no reviews yet.