Content | Ortofon 310 Stylus Technical Data
- Frequency range 20-20.000 Hz
- Frequency response 20-18.000 Hz + 2 / - 3 dB
- Tracking ability at 315Hz at recommended tracking force 60 µm
- Compliance, dynamic, lateral 20 µm/mN
- Stylus type Elliptical
- Stylus tip radius r/R 8/18 µm
- Equivalent stylus tip mass 0,5 mg
- Tracking force range 1,25-1,75 g (12,5-17,5 mN)
- Tracking force, recommended 1,5 g (15 mN)
- Tracking angle 20°
- Stylus colour Grey
- Recommended for following cartridges Series 310 Universial
|
| Stylus 2M Blue
Technical data |
|
Frequency range |
20-25.000 Hz |
Frequency response |
20-20.000 Hz + 2 / - 1 dB |
Tracking ability at 315Hz at recommended tracking force *) |
80 µm |
Compliance, dynamic, lateral |
20 µm/mN |
Stylus type |
Nude Elliptical |
Stylus tip radius |
r/R 8/18 µm |
Equivalent stylus tip mass |
0,5 mg |
Tracking force range |
1,6-2,0 g (16-20 mN) |
Tracking force, recommended |
1,8 g (18 mN) |
Tracking angle |
20° |
Stylus colour |
Blue |
|
|
Recommended for following cartridges |
2M Blue |
*) Typical value | Ortofon 520MKII Stylus Technical Data
- Frequency range 20-23.000 Hz
- Frequency response 20-20.000 Hz + 2 / - 3 dB
- Tracking ability at 315Hz at recommended tracking force 70 µm
- Compliance, dynamic, lateral 25 µm/mN
- Stylus type Nude Elliptical
- Stylus tip radius r/R 8/18 µm
- Equivalent stylus tip mass 0,3 mg
- Tracking force range 1,25-1,75 g (12,5-17,5 mN)
- Tracking force, recommended 1,5 g (15 mN)
- Tracking angle 20°
- Stylus colour Black
- Recommended for following cartridges Series 520 Mkll, 520, 520 P
|
| Ortofon 320 Stylus Technical Data
- Frequency range 20-22.000 Hz
- Frequency response 20-20.000 Hz + 2 / - 3 dB
- Tracking ability at 315Hz at recommended tracking force 70 µm
- Compliance, dynamic, lateral 25 µm/mN
- Stylus type Nude Fine Line
- Stylus tip radius r/R 8/40 µm
- Equivalent stylus tip mass 0,5 mg
- Tracking force range 1,25-17,5 g (12,5-17,5 mN)
- Tracking force, recommended 1,5 g (15 mN)
- Tracking angle 20°
- Stylus colour Grey
- Recommended for following cartridges Series 320 Universal
|
|
Stylus 40
Technical data |
| Frequency range | 20-30.000 Hz | Frequency response | 20-30.000 Hz + 2 / - 3 dB | Tracking ability at 315Hz at recommended tracking force *) | 90 µm | Compliance, dynamic, lateral | 25 µm/mN | Stylus type | Nude FG 70 | Stylus tip radius | r/R 5/70 µm | Equivalent stylus tip mass | 0,3 mg | Tracking force range | 1,25-1,75 g (12,5-17,5 mN) | Tracking force, recommended | 1,5 g (15 mN) | Tracking angle | 20° | Stylus colour | Black |
| | Recommended for following cartridges | OM 40, OM 40 GOLD | *) Typical value |
Technical data |
|
Frequency range |
20-29.000 Hz |
Frequency response |
20-20.000 Hz + 2 / -0 dB |
Tracking ability at 315Hz at recommended tracking force *) |
80 µm |
Compliance, dynamic, lateral |
22 µm/mN |
Stylus type |
Nude Fine Line |
Stylus tip radius |
r/R 8/40 µm |
Tracking force range |
1,4-1,7 g (14-17 mN) |
Tracking force, recommended |
1,5 g (15,0 mN) |
Tracking angle |
20° |
Stylus colour |
Bronze |
|
|
Recommended for following cartridges |
2M BRONZE |
|
Reviews