SAMSON CL8 MULTI-PATTERN STUDIO CONDENSER MICROPHONE

Discontinued

148.55 incl. GR VAT

Out of stock

CompareAdd to wishlist Submit Better Price
The CL8 has a true capacitor condenser mic element design with dual 1.1-inch, ultra thin gold spluttered diaphragm capsules giving it the ability of multi pattern operation. Capacitor-based elements are warmer, brighter and bigger sounding than electret-based elements, which is why they are able to faithfully reproduce a variety of sound sources with amazing clarity […]

 

Read more

The CL8 has a true capacitor condenser mic element design with dual 1.1-inch,
ultra thin gold spluttered diaphragm capsules giving it the ability of multi pattern
operation. Capacitor-based elements are warmer, brighter and bigger sounding
than electret-based elements, which is why they are able to faithfully reproduce
a variety of sound sources with amazing clarity and detail.
 
True Capacitor Large Diaphram Multi-Pattern Studio Condenser
Switchable Super Cardioid, Omni and Figure-8 pickup patterns
Dual 1.1″ Capsules with 3-micron Gold Sputtered Diaphragms
Switchable Hi-pass Filter, 12dB per octave at 100 Hz
Switchable 10 dB PAD for handling signals with high SPLs
36-52 Volt Phantom Power operation
Internal Shock-mount
Solid Die Cast construction
Swivel Stand Mount and Carry Case included
 

Weight 1.00 kg

Reviews

There are no reviews yet.

Be the first to review “SAMSON CL8 MULTI-PATTERN STUDIO CONDENSER MICROPHONE”

Your email address will not be published. Required fields are marked *

Quick Comparison

SAMSON CL8 MULTI-PATTERN STUDIO CONDENSER MICROPHONE removeAKG C 3000B Condenser cardioid microphone removeAKG PERCEPTION 120 Condenser microphone removeAKG PERCEPTION 220 CONDENSER MICROPHONE removeNEUMANN TLM-103 Condenser studio microphone removeRODE NT-2000 LARGE-DIAPHRAGM CONDESER MICROPHONE remove
NameSAMSON CL8 MULTI-PATTERN STUDIO CONDENSER MICROPHONE removeAKG C 3000B Condenser cardioid microphone removeAKG PERCEPTION 120 Condenser microphone removeAKG PERCEPTION 220 CONDENSER MICROPHONE removeNEUMANN TLM-103 Condenser studio microphone removeRODE NT-2000 LARGE-DIAPHRAGM CONDESER MICROPHONE remove
Image
SKUCL-8C 3000BPERCEPTION 120PERCEPTION 220H11NE00039H11RD00003
Rating
Price 148.55 incl. GR VAT 209.99 incl. GR VAT 110.00 incl. GR VAT 180.00 incl. GR VAT 1,169.00 incl. GR VAT 529.00 incl. GR VAT
Stock

Out of stock

In stock (can be backordered)

In stock

In stock

In stock

In stock

AvailabilityOut of stockIn stock (can be backordered)In stockIn stockIn stockIn stock
Add to cart

Read more

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description
Content

The CL8 has a true capacitor condenser mic element design with dual 1.1-inch,
ultra thin gold spluttered diaphragm capsules giving it the ability of multi pattern
operation. Capacitor-based elements are warmer, brighter and bigger sounding
than electret-based elements, which is why they are able to faithfully reproduce
a variety of sound sources with amazing clarity and detail.
 
True Capacitor Large Diaphram Multi-Pattern Studio Condenser
Switchable Super Cardioid, Omni and Figure-8 pickup patterns
Dual 1.1" Capsules with 3-micron Gold Sputtered Diaphragms
Switchable Hi-pass Filter, 12dB per octave at 100 Hz
Switchable 10 dB PAD for handling signals with high SPLs
36-52 Volt Phantom Power operation
Internal Shock-mount
Solid Die Cast construction
Swivel Stand Mount and Carry Case included
 

 
  • Polar pattern: Cardioid
  • Switchable -10dB PAD
  • Frequency response: 20 - 20,000 Hz
  • Max. SPL: 140/150 dB (THD = 0.5%)
  • Electrical impedance: 200 Ohm
  • Requires phantom power
  • Diameter: 53 mm
  • Length: 162 mm
  • Net weight: 320 g
  • Colour: Black
  • Incl. shock mount
  • Highly affordable AKG large-diaphragm microphone technology
  • Cardioid polar pattern for multiplicity of vocal and instrument applications
The earlier model C 3000 has had a large fan club in the project studio and home recording worlds for years. For the new C 3000 B, AKG designed a special 1-inch large-diaphragm transducer that closely approximates the vibration performance of top-class studio microphones, but can be made at much lower cost. Due to its surface area and special capsule tuning, the C 3000 B large-diaphragm transducer produces an exceptionally pleasing, smooth sound. Unlike in the C 3000, the switchable 10-dB preattenuation pad immediately follows the transducer in the signal path, thus increasing the C 3000 B\'s SPL capability by a true 10 dB. Loud sound sources are therefore no problem. An acoustically optimized cardioid polar pattern makes the C 3000 B an excellent choice for both recording and live sound applications where high gain before feedback is paramount.
Polar pattern cardioid
Frequency range 20 to 20,000 Hz
Sensitivity 25 mV/Pa (-32 dBV)
Max. SPL 140/150 dB (k=0,5%)
Equivalent noise level (CCIR 468-3) 25 dB
Equivalent noise level 14 dB-A
Signal/noise ratio (A-weighted) 80 dB
Preattenuation pad 10 dB, switchable
Bass filter 6 dB/octave below 500 Hz
Impedance 200 ohms
Recommended load impedance >1000 ohms
Supply voltage 9 to 52 V phantom power to DIN 45596
Current consumption
Connector 3-pin XLR
Finish silver gray
Net weight 320 g / 11.3 oz.
Shipping weight 950 g / 2.1 lbs.
Patent(s) Electrostatic transducer (Patent no. AT 395.225, DE 4.103.784, JP 2.815.488)
Live sound
Podcasting Home recording Vocals Musical instruments Perception 120
  • General-purpose cardioid recording microphone
  • Extended frequency response
  • Roadworthy construction
  • Switchable 20 dB preattenuation pad
  • Switchable bass cut filter
  • Designed and engineered by AKG in Vienna, Austria
The Perception 120 is a 2/3-inch diaphragm true condenser microphone that offers solid build quality, outstanding performance, and excellent value. The low-mass diaphragm delivers a clear sound with accurate sonic detail. A switchable 20 dB preattenuation pad and bass cut filter make the Perception 120 an excellent choice for a wide range of recording and live sound applications. Backed by AKG\'s six decades of experience in making microphones and input from sound engineers around the world, the Perception 120 now brings AKG studio quality to musicians and project studio applications.
Type 2/3\" Diaphragm True Condenser
Polar pattern cardioid
Frequency range 20 to 20,000 Hz
Sensitivity 22 mV/Pa (-33 dBV)
Max. SPL 130/150 dB (0/-20 dB) for 0.5% THD
Equivalent noise level 22 dB-A (IEC 60268-4)
Signal/noise ratio (A-weighted) 72 dB
Preattenuation pad 0 dB, -20 dB
Bass filter 12 dB/octave at 300 Hz
Impedance
Recommended load impedance >= 1,000 ohms
Powering
Power requirement 48 V phantom power to DIN/IEC
Connector 3-pin XLR
Finish metallic blue
Dimensions 53 dia. x 165 mm (2.1 dia. x 6.5 in.)
Net weight 525 g (18.5 oz.)
Shipping weight 955 g (33.7 oz.)
  • One-inch large-diaphragm, true condenser cardioid transducer
  • Rugged all-metal body
  • Roadworthy construction
  • Switchable 20 dB preattenuation pad
  • Switchable bass cut filter
  • Legendary AKG sound quality
  • Designed and engineered by AKG in Vienna, Austria
  • Comes with spider-type shock mount and aluminium carrying case
The Perception 220 is a large-diaphragm true condenser microphone offering outstanding build quality and excellent value. Its many useful features and included accessories make this microphone uncommonly versatile. It delivers a classic warm, clear sound and conforms to the stringent standards defined for AKG recording products. These standards are based on AKG΄s six decades of experience in making microphones and on input from sound engineers around the world who use AKG products every day. Its 1-inch large-diaphragm true condenser transducer brings AKG studio quality to the project studio as well as all other areas of recording and live sound applications. A switchable bass cut filter and preattenuation pad make it perfectly suited even for use on loud sound sources producing sound pressure levels up to 155 dB SPL. The rugged and roadworthy design makes it also a perfect choice for on-stage applications. The Perception 220 comes with a spider-type shock mount and a rugged metal case.
Type 1" Large Diaphragm True Condenser
Polar pattern cardioid
Frequency range 20 to 20,000 Hz
Sensitivity 18 mV/Pa (-35 dBV)
Max. SPL 135 dB/155 dB (0/-20 dB) for 0.5% THD
Equivalent noise level 16 dB-A (IEC 60268-4)
Signal/noise ratio (A-weighted) 78 dB
Preattenuation pad 0 dB, -20 dB
Bass filter 12 dB/octave at 300 Hz
Impedance =1000 ohms
Current consumption
Large diaphragm cardioid microphone
Pressure gradient transducer with with one-diaphragm capsule
Transformerless circuitry
Extremely low noise: 7 dB-A
Includes swivel mount
Straightforward handling for homerecording and professional studios

High-quality professional equipment for limited budgets

Acoustical operating principle Pressure gradient transducer
Directional pattern Cardioid
Frequency range 20 Hz ... 20 kHz
Sensitivity at 1 kHz into 1 kohm 23 mV/Pa
Rated impedance 50 ohms
Rated load impedance 1 kohms
Equivalent noise level, CCIR1) 17.5 dB
Equivalent noise level, A-weighted1) 7 dB-A
Signal-to-noise ratio, CCIR1) (rel. 94 dB SPL) 76.5 dB
Signal-to-noise ratio, A-weighted1) (rel. 94 dB SPL) 87 dB
Maximum SPL for THD 0.5%2) 138 dB
Maximum output voltage 13 dBu
Dynamic range of the microphone amplifier (A-weighted) 131 dB
Supply voltage (P48, IEC 61938) 48 V ± 4 V
Current consumption (P48, IEC 61938) 3 mA
Matching connector XLR3F
Weight approx. 450 g
Diameter 60 mm
Length 132 mm

 

NT2000 - ?Explore, Control, Create?? Seamlessly Variable Dual 1? Condenser Microphone.

The world's first large diaphragm condenser studio microphone with seamlessly variable Polar
Patterns, Filter and Pad located conveniently on the microphone body. The NT2000?s state of
the art surface-mount electronics combined with the new Australian designed and manufactured
HF1 Capsule, provide extremely low self-noise (7 dBA) and a maximum SPL of 147 dB (157 dB
with pad fully engaged) ensuring exceptional results and the ultimate in recording creativity.
The NT2000 is supplied with the SM2 Shock Mount, together in a durable custom carry case.

SPECIFICATIONS:
Acoustic principle:
Externally polarised 25 mm (1?) dual diaphragm condenser
Directional pattern: Multipattern
Frequency range:  20Hz - 20KHz
Output impedance: 200 ohms
Signal noise ratio din iec 651:  87 dB (1kHz rel 1Pa)
Equvalent noise: 7 dBA SPL (per IEC651, IEC268-15)
Maximum spl:
147 dB (@ 1% THD into 1K ohm) 157dB (@ 1% THD into 1K ohm) with pad set to maximum
Sensitivity:
-36 db re 1 Volt/Pasca (16 mv @94db SPL) +/- 2 dB
Dynamic range din iec 651: 140 dB (per IEC651, IEC268-15)
Power supply voltage: Phantom P48
Weight without battery: 831 gm
Weight with battery:  2.6 kg
 

Weight1.00 kg1.00 kg0.50 kg1.00 kg3.00 kg3.00 kg
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Weight 1.00 kg
Weight 1.00 kg
Weight 0.50 kg
Weight 1.00 kg
Weight 3.00 kg
Weight 3.00 kg