Hypercardioid polar pattern 50 cm ( 20 in.) long 95° pickup angle For acoustically difficult environments Connects easily via XLR connector The hypercardioid polar pattern with its narrow 95° pickup angle is suited best for situations where noise typically occurs from all sides (particularly in worship centers), where people talk into the microphone from a […]

 

Read more

  • Hypercardioid polar pattern
  • 50 cm ( 20 in.) long
  • 95° pickup angle
  • For acoustically difficult environments
  • Connects easily via XLR connector

The hypercardioid polar pattern with its narrow 95° pickup angle is suited best for situations where noise typically occurs from all sides (particularly in worship centers), where people talk into the microphone from a greater distance, or where several talkers are grouped side by side. Two different lengths are available. The .exible joint ensures optimum alignment of the gooseneck to any talker position. Several options are available for installation, i.e., stand, tabletop installation, and lockable.

Choosing polar patterns

Selecting the correct polar pattern for installed sound is difficult since it depends on a variety of factors. Of course the acoustics of the room play a key role. For highly reverberant rooms such as worship centers, a hypercardioid polar pattern will be the best choice to avoid high levels of unwanted noise. Correct placement of the loudspeakers is also essential. If the speakers project right at the capsule, a hypercardioid will be your best bet. The most difficult task, however, is trying to judge how the talkers will behave. For talkers who are inexperienced or move around a lot, be sure to choose a cardioid polar pattern for reliable pickup; talkers at a greater distance from the mic will be served best by a hypercardioid.

The microphone shall be a hypercardioid gooseneck microphone. Its pickup angle shall be 95 degrees; frequency range 50 Hz to 19 kHz; sensitivity 12 mV/Pa; max. SPL 125 dB; electrical impedance

 

Polar pattern Hypercardioid
Frequency range 50 to 19,000 Hz
Sensitivity 12 mV/PA = -38 dBV re 1 V/Pa
Max. SPL 125 dB (for 1% THD)
Equivalent noise level
Signal/noise ratio (A-weighted) >73 dB
Impedance =2,000 ohms
Supply voltage English: 9 to 52 V phantom power to IEC 61938 (DPA adapter integrated)
Powering
Connector 3-pin male XLR
Finish matte black
Dimensions CGN 99 H/S: 13.5 x 380 mm (0.5 x 15 in.);
CGN 99 H/L: 13.5 x 580 mm (0.5 x 23 in.)
Net weight

CGN 99 H/S: 480 g (17 oz.);
CGN 99 H/L: 500 g (17.7 oz.)

 

 Optional accessories

  B 18
Battery power supply
 
  H 500
Shock mount
 
  H 600
Shock mount
 
  PS 3 F-Lock
Installation hardware
 
  SA 60
Stand adapter
 
  ST 1
Mini-tripod
 
  ST 45
Table stand
 

 

Weight 0.48 kg

Reviews

There are no reviews yet.

Be the first to review “AKG CGN 99H/L 58cm Hypercardioid Gooseneck Microphone”

Your email address will not be published. Required fields are marked *

Quick Comparison

AKG CGN 99H/L 58cm Hypercardioid Gooseneck Microphone removeAKG CHM 99 CARDIOID CONDENSER HANGING MICROPHONE removeAKG DGN 99E dynamic cardioid Gooseneck Microphone WITH XLR removeAKG C 518 M Miniature Cardioid Condenser Microphone removeSHURE WB-98H/C Instrument Microphone for Shure Wireless removeAKG C 519 ML Miniature Condenser Clip-On Microphone remove
NameAKG CGN 99H/L 58cm Hypercardioid Gooseneck Microphone removeAKG CHM 99 CARDIOID CONDENSER HANGING MICROPHONE removeAKG DGN 99E dynamic cardioid Gooseneck Microphone WITH XLR removeAKG C 518 M Miniature Cardioid Condenser Microphone removeSHURE WB-98H/C Instrument Microphone for Shure Wireless removeAKG C 519 ML Miniature Condenser Clip-On Microphone remove
Image
SKUCGN 99H/LCHM 99 WHITEDGN 99EC 518 MWB98HCC 519 ML
Rating
Price 129.00 incl. GR VAT 186.21 incl. GR VAT 178.99 incl. GR VAT 264.00 incl. GR VAT 219.00 incl. GR VAT 185.00 incl. GR VAT
Stock

Out of stock

Available on backorder

Available on backorder

In stock

Only 1 left in stock (can be backordered)

Available on backorder

AvailabilityOut of stockAvailable on backorderAvailable on backorderIn stockOnly 1 left in stock (can be backordered)Available on backorder
Add to cart

Read more

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description
Content
  • Hypercardioid polar pattern
  • 50 cm ( 20 in.) long
  • 95° pickup angle
  • For acoustically difficult environments
  • Connects easily via XLR connector

The hypercardioid polar pattern with its narrow 95° pickup angle is suited best for situations where noise typically occurs from all sides (particularly in worship centers), where people talk into the microphone from a greater distance, or where several talkers are grouped side by side. Two different lengths are available. The .exible joint ensures optimum alignment of the gooseneck to any talker position. Several options are available for installation, i.e., stand, tabletop installation, and lockable.

Choosing polar patterns

Selecting the correct polar pattern for installed sound is difficult since it depends on a variety of factors. Of course the acoustics of the room play a key role. For highly reverberant rooms such as worship centers, a hypercardioid polar pattern will be the best choice to avoid high levels of unwanted noise. Correct placement of the loudspeakers is also essential. If the speakers project right at the capsule, a hypercardioid will be your best bet. The most difficult task, however, is trying to judge how the talkers will behave. For talkers who are inexperienced or move around a lot, be sure to choose a cardioid polar pattern for reliable pickup; talkers at a greater distance from the mic will be served best by a hypercardioid.

The microphone shall be a hypercardioid gooseneck microphone. Its pickup angle shall be 95 degrees; frequency range 50 Hz to 19 kHz; sensitivity 12 mV/Pa; max. SPL 125 dB; electrical impedance

 

Polar pattern Hypercardioid
Frequency range 50 to 19,000 Hz
Sensitivity 12 mV/PA = -38 dBV re 1 V/Pa
Max. SPL 125 dB (for 1% THD)
Equivalent noise level
Signal/noise ratio (A-weighted) >73 dB
Impedance =2,000 ohms
Supply voltage English: 9 to 52 V phantom power to IEC 61938 (DPA adapter integrated)
Powering
Connector 3-pin male XLR
Finish matte black
Dimensions CGN 99 H/S: 13.5 x 380 mm (0.5 x 15 in.);
CGN 99 H/L: 13.5 x 580 mm (0.5 x 23 in.)
Net weight

CGN 99 H/S: 480 g (17 oz.);
CGN 99 H/L: 500 g (17.7 oz.)

 

 Optional accessories

  B 18
Battery power supply
 

  H 500
Shock mount
 

  H 600
Shock mount
 

  PS 3 F-Lock
Installation hardware
 

  SA 60
Stand adapter
 

  ST 1
Mini-tripod
 

  ST 45
Table stand
 

 

  • Cardioid polar pattern
  • 10 m (33 ft.) cable
  • 125° pickup angle
  • Especially suited for choir recordings
  • Integrated spring steel clamp for optimum alignment

The new CHM 99 Condenser Hanging Microphone provides both ease of use and a high level of functionality. There is hardly any more affordable and simpler solution for recording choirs at worship centers. Suspended from the ceiling or a beam, the hanging microphone is aligned and then fixed in the correct position. Now use the spring steel clamp to adjust the correct angle, and off you go!
The CHM 99 is available in white or black.

XY stereo recording

Using two CHM 99 hanging microphones in an XY configuration (coincident pair) is a good way to make stereo recordings, particularly of choirs. However, sound source locations are defined only by intensity differences. Adjusting the angle between the microphones determines the width and depth of the stereo image.

ORTF stereo recording

Developed by the French Broadcasting Authority, this technique differs from the XY technique by recording not only intensity differences, but also delay differences. The capsules are aligned at an angle of precisely 110° and 170 mm / 6.7 in. apart.

Polar pattern    Cardioid
Frequency range    70 to 18,000 Hz
Sensitivity    18 mV/PA = -35 dBV re 1 V/Pa
Max. SPL    125 dB (for 1% THD)
Equivalent noise level    73 dB
Impedance    =2,000 ohms
Supply voltage    9 to 52 V phantom power to IEC 61938 (DPA adapter integrated)
Powering   
  • PA microphone with rugged, all-metal body
  • Frequency response optimized for intelligibility
  • Long useful life even in tough day-to-day usage
  • Frequency response tailored to speech use
Rugged, affordable dynamic cardioid gooseneck microphone for general public address and communications use. The DGN 99 provides a frequency response tailored to speech use for optimum intelligibility as well as good offaxis rejection for high gain before feedback and suppression of unwanted ambient noise. The all-metal body ensures a long useful life for the microphone even in tough day-to-day use.

The DGN 99 E features a built-in XLR connector for quick connection, while the DGN 99 has been designed for permanent (single-hole or screw-on) installation and comes with a 6-ft. 4-in. (2-m) fixed, unterminated cable.

 

Ticket window, bank counter
Reception desk, restaurant
Houses of worship

Features:

  • Miniature cardioid condenser clamp-on microphone with shock mounted capsule
  • Ideal for miking drums and percussions
  • Including wireless direct adapter for easy use with AKG pocket transmitters
  • Detachable microphone cable
  • Integrated gooseneck
  • Continuously adjustable vise type clamp

Recommended For:

  • Drums
  • Brass
  • Recording
  • Percussions

Standard Accessories:

  • A400 adapter
  • H518 Drum bracket
  • Microphone bag
  • W44 Windscreen

Specs:

  • Polar pattern cardioid
  • Frequency range 60 Hz to 20 kHz
  • Sensitivity 5 mV/Pa (-46 dBV)
  • Max. SPL 130/132 dB SPL (for 1%/3% THD)
  • Equivalent noise level 31 dB(A)
  • Signal/noise ratio (A-weighted) 63 dB
  • Impedance = 2000 ohms
  • Current consumption


The 98H/C is wireless version of Shure\'s Beta 98 clip-on instrument mic, and is designed to work with the Shure beltpack transmitters. With the ability to handle high SPL, the Beta 98H/C is ready for the demands of brass, woodwind, and percussion, and features a flexible integrated gooseneck with clip-on clamp for secure fit and precise positioning. No external mounting hardware required.

    

Tech Specs
  • Compatibility: All Shure w/TA4F (Tiny QG)
  • Microphone Type: Condenser
  • Polar Pattern: Cardioid
  • Frequency Response: 20Hz-20kHz
  • Max SPL: 143.5dB SPL
  • Signal to Noise Ratio: 63dB
  • Self Noise: 31dB (A weighted)
  • Connector: TA4F (For Shure)
  • Color: Black
  • Cable Length: 10 ft.
  • Weight: .1 lb.
  • Manufacturer Part Number: WB98H/C

Recommended For:

  • Brass
  • Drums
  • Percussions
  • Woodwinds

Features:

  • Miniature condenser clip-on microphone for wind instruments, drums, and percussions
  • Miniature gooseneck for accurate microphone alignment
  • Including wireless direct adapter for easy use with AKG pocket transmitters
  • Detachable microphone cable
  • Transducer shock mount for high mechanical-noise rejection

Standard Accessories:

  • A400 adapter
  • Microphone bag
  • W44 Windscreen

Specs:

  • Polar pattern cardioid
  • Frequency range 60 Hz to 20 kHz
  • Sensitivity 5 mV/Pa (-46 dBV)
  • Max. SPL 130/132 dB SPL (for 1 %/3 % THD)
  • Equivalent noise level 31 dB(A)
  • Signal/noise ratio (A-weighted) 63 dB
  • Impedance = 2000 ohms
  • Current consumption
Weight0.48 kg0.50 kg0.48 kg0.45 kg0.40 kg0.31 kg
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Weight 0.48 kg
Weight 0.50 kg
Weight 0.48 kg
Weight 0.45 kg
Weight 0.40 kg
Weight 0.31 kg