Content | Adam Hall KQMC04 Multicore Quantum 04 channel black
Stage & Live Multicore - 2 pair is exactly the cable all ?bending radius fetishists?, such as live technicians, musicians
and ambitious live sound people have been dreaming of! The QUANTUM is absolutely torsion-free, i.e. it can be wound
in the shape of an ?8? without any problems and will not twist when it is wound or unwound. each wire pair is additionally
insulated with a sleeve, numbered, and shielded with a copper spiral covered to 99%.
Center conductor cross section
0.22 mm²
Center conductor material
Copper bare, OFC
Center conductor construction
28 x 0.10 mm
Number of internal conductors
4 x 2
Shield material
Aluminium mylar foil / copper tin-plated
Line resistance
87 Ohm(s)
insulating resistance
> 1 G
Operating Temperature
-20 - 70 °C
Surge Impedance
120 ohm/km
| Multicore cable 8 pair studio with numbercode, black
All pairs are wear-resistant number coded as well as colour coding
in multiples of eight. Each pair has a pre-twisted drain wire and
additional AL/PT foil shielding for protection against corrosion and
oxidisation. Conductors and drain wire are tin plated. |
24 AWG stranded (7x32) TC conductor, polyolefin insulation, individually shielded Beldfoil? (100% coverage) numbered/color-coded PVC jackets, jackets and shields bonded to strip simultaneously, overall Beldfoil shield and 24 AWG TC drain wire. PHYSICAL CHARACTERISTICS : CONDUCTOR : Number of Pairs: 4 Total Number of Conductors: 8 AWG: 24 Stranding: 7x32 Conductor Diameter: .024 in. Conductor Material: TC - Tinned Copper INSULATION : Insulation Material: PO - Polyolefin Nom. Insulation Wall Thickness: .008 in. Insulation Diameter: .040 in. Lay Length: 1.75 in. Twists/ft.: 6.85 Pair Color Code Chart: Red & Black INNER SHIELD : Inner Shield Material Trade Name: Beldfoil? Inner Shield Type: Tape Inner Shield Material: Aluminum Foil-Polyester Tape Inner Shield % Coverage: 100 % Inner Shield Drain Wire AWG: 24 Inner Shield Drain Wire Stranding: 7x32 Inner Shield Drain Wire Conductor Material: TC - Tinned Copper INNER JACKET : Inner Jacket Material: PVC - Polyvinyl Chloride Inner Jacket Nominal Wall Thickness: .014 in. Inner Jacket Diameter: .111 in. Inner Jacket Color Code Chart: Number Color 1 Brown 2 Red 3 Orange Number Color 4 Yellow OUTER SHIELD : Outer Shield Material Trade Name: Beldfoil? Outer Shield Type: Tape Outer Shield Material: Aluminum Foil-Polyester Tape Outer Shield %Coverage: 100 % OUTER SHIELD DRAIN WIRE : Outer Shield Drain Wire AWG: 18 Outer Shield Drain Wire Stranding: 7x26 Outer Shield Drain Wire Conductor Material: TC - Tinned Copper OUTER JACKET : Outer Jacket Material: PVC - Polyvinyl Chloride Outer Jacket Nominal Wall Thickness: .037 in. Outer Jacket Ripcord: Yes OVERALL NOMINAL DIAMETER : Overall Nominal Diameter: .352 in. MECHANICAL CHARACTERISTICS : Operating Temperature Range: -35°C To +75°C Bulk Cable Weight: 51.9 lbs/1000 ft. Max. Recommended Pulling Tension: 88.4 lbs. Min. Bend Radius (Install): 3.5 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE : APPLICABLE STANDARDS : NEC/(UL) Specification: CM CEC/C(UL) Specification: CM EU CE Mark (Y/N): Yes EU RoHS Compliant (Y/N): Yes EU RoHS Compliance Date (mm/dd/yyyy):: 01/01/2004 PLENUM/NON-PLENUM : Plenum (Y/N): N ELECTRICAL CHARACTERISTICS : Nom. Inductance: .18 ?H/ft Nom. Capacitance Conductor to Conductor @ 1 KHz: 31 pF/ft Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz: 58 pF/ft Nominal Velocity of Propagation: 66 % Nom. Conductor DC Resistance @ 20 Deg. C: 23.3 Ω/1000 ft Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 15.9 Ω/1000 ft Max. Operating Voltage - UL: 300 V RMS Max. Recommended Current: 1.05 Amps per conductor @ 25°C | Adam Hall Cables 4 STAR HPD 325 Hybrid Cable Power & DMX 3 x 2.5 mm² & 2 x 0.22 mm². Price per meter
Type
Power / Signal Cable
Temperature range
-20 - 70 °C
Power
Number of internal conductors
3
Center conductor cross section
2.5 mm²
Center conductor construction
96 x 0.10 mm
Center conductor material
OFC
DMX
Number of inner conductors 2
2
Center conductor cross section 2
0.22 mm²
Center conductor construction 2
7 x 0.20 mm
Center conductor material 2
OFC
Shield
Aluminium foil, Copper spiral coil shield
Conductor resistance 2
85 ohm/km
| Adam Hall Cables 4 STAR HPD 315 Hybrid Cable Power & DMX 3 x 1.5 mm² & 2 x 0.22 mm². Price per meter
General
Type
Power / Signal Cable
Temperature range
-20 - 70 °C
Power
Number of internal conductors
3
Center conductor cross section
1.5 mm²
Center conductor construction
48 x 0.20 mm
Center conductor material
OFC
Conductor resistance
85 ohm/km
DMX
Number of inner conductors 2
2
Center conductor cross section 2
0.22 mm²
Center conductor construction 2
7 x 0.20 mm
Center conductor material 2
OFC
Shield
AL/PT-foil, Copper spiral coil shield
Conductor resistance 2
85 ohm/km
|
A P P L I C A T I O N Analogue audio Fixed installations Audio transmissions in noisy environment Wiring in professional sound studios P R O D U C T A D V A N T A G E S Very good protection against electromagnetique interferences thanks to individually shielded pairs and overall shield T E C H N I C A L D A T A NO. OF CONDUCTORS: No. x 2 x 0,22 mm2 Tinned copper CONDUCTOR INSULATION: PE SHIELDING BY PAIR: Aluminium polyester foil + drain wire COLOR OF CONDUCTEUR: White / blue COLOR OF PAIR: By number OVERALLSHIELD: Aluminium polyester foil + drain wire JACKET: Black PVC PACKAGING: Per m SUITABLE PLUG: XLR, jacks PRICE PER METER
|
Reviews
There are no reviews yet.