Content | DIMIC12 is a selective progammable digital paging station with the possibility to communicate with different zones in your office. The DIMIC12 can be used for 12 different zones. When the DIMIC12 is used with AUDIOCONTROL12.8 you can allocate buttons to perform actions like opening a door, controlling a sound source, ring a bell or even start a series of commands.
This paging station is designed for use with AUDIOCONTROL12.8 and easy to configure via the hostʼs graphical user interface. DIMIC12 combines an inconspicious and elegant design with a remarkable sound quality. It has speech-optimized sound processing and a unidirectional condenser microphone. |
The AT series high quality attenuators features 5 attenuation settings ,,OFF'' -18dB,-12db,-6dB,-0dB. An input range from 0.5W to 60W (model dependent), and push-in connectors. Push-in connector allows quick terminal cable connection. Stylishly finished, the AT Series will suit any décor. |
The RM-210 is an extension unit for increasing the number of function keys of TOA's RM-200M, RM-200XF and RM-200X Remote Microphones.
Specification |
| Current Consumption | 20mA max. (in terms of RM-200M's DC power input 75mA max. (interms of DC power inputs of RM-200X and RM-200XF) | Connection | Connection to RM-200M, RM-200X or RM-200XF by way of dedicated Cable | Number of Function | Keys 10 | Function | When used to expand the RM-200M:
Selects and activates the Voice Announcement Board messages.
When used to expand the RM-200X and RM-200XF (PC software setting):
Emergency activation, emergency reset, BGM pattern selection, EV message activation, broadcast zone selection, monitor zone selection, chime activation, Talk switch activation, control output activation, input volume adjustment, zone volume adjustment, and failure output indication and reset. | Finish | ABS resin, bluish gray (PANTON 538 or its equivalent) | Dimensions | 110 (W) x 76.5 (H) x 215 (D)mm | Weight | 350g | Accessory | Extension cable x 1, Linkage bracket A x 1, Linkage bracket B x 1, Screw for linkage bracket x 12 |
|
*Convenient Priority Broadcasting
*Convenient Installation and Construction without ID Setting
*RS-422 Communication between RM-500 and Z-500
*21 Zone Paging Selection
*Output Signal Level Display
*Multi Chime Options
*Weight: 1.6kg/3.5Ib
*DImensions(W×H×D): 200×206×70mm/7.9×8.1×2.8in
|
| - SYSTEM POWER CONTROL You can control the power of your system by using this model. - AC AND DC POWER SUPPLY You can distribute AC and DC power through the AC outlet and DC terminals on the rear panel. - USE OF EMERGENCY POWER SUPPLY For emergency equipment power supply, an extra DC terminal is provided. - REMOTE CONTROL You can control the system power by remote control function even though the power switch on front is off. - AC AND DC VOLT METER This model uses digital volt meter displays of AC and DC. - OPERATING MODE DISPLAY You can easily check the operating mode by LEDs, AC or DC operating and emergency power. | | | | | PD-659 | AC Outlet | Switched 2000W ⅹ3 | Unswitched 700W ⅹ1 | Remote Control | 1 | DC Power Output | DC 24V 5A | Operation Temperature | -10℃~+40℃ | Power Source | 100-120VAC or 220-240VAC; 50/60Hz (Supplied ACmains transformer depends on country requirements) | Power Consumption | 190W | Weight(SET) | 6.2Kg/13.6Ib | Dimension(SET) | 482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in | ※ Specifications and design subject to change without notice. | | | |
|
- CONSIDERATION OF USERʼS CONVENIENCE NUMERIC buttons and various function buttons are separated for timer program enter and convenience in use so that the user can easily operate. - ADOPTION OF VACUUM FLUORESCENT DISPLAY PANEL Adopting a vacuum fluorescent display of a dot matrix method enables to check operation status of each function at a glimpse. - PROGRAMMING USING A PC You can easily execute reservation setting thorough management program by connecting a PC to the RS-232C port. - VARIOUS MELODY AND SOUND OUTPUT You can generate various melodies and sounds by linking the flash memory mounted on this unit to our model, PV-632 (MULTI-VOICE FILE). - AC POWER OUTPUT CONTROL When PW-642 and other equipment are connected via the AC outlet terminal of PW-642, you can turn ON/OFF the AC outlet button in the front panel and manually control ON/OFF of the AC power connected to other device. - BACK-UP POWER You can continue to maintain the time counter for about a week though the inner back-up even though AC power turns off with current time set. There is no need of readjusting time even though AC power is applied. - MEASURE AGAINST POWER FAILURE A separate memory is used to prevent data extinguishment due to power failure or other unstable power. - AUTOMATIC RETURN In programming data using a key button on the front side of PW-642 without using a PC, no pressing any button is recognized as cancel of program entry to return to normal operation status. - AC POWER OUTPUT TIME ADJUSTMENT You can adjust the AC power output time of PW-642 by 1~20sec to prevent time delay from occurring in the interface with the outside power amp. - KEY LOCK You can protect reservations and userʼs setting. |
|
|
| | PW - 642 | Input Channel (Balanced) | 5CH | Output Channel (Balanced) | 4CH | Output Level | Maximum 1v | AC Power Output 1 | Maximum 500W | AC Power Output 2 | Maximum 30 w | Data Preservation Time | 7 days and more | Melody Time (15 settings total - 247 seconds) | No.1 | 2 seconds | No.2 | 3 Seconds | No.3 | 3 Seconds | No.4 | 5 Seconds | No.5 | 5 Seconds | No.6 | 7 Seconds | No.7 | 7 Seconds | No.8 | 10 Seconds | No.9 | 10 Seconds | No.10 | 15 Seconds | No.11 | 20 Seconds | No.12 | 30 Seconds | No.13 | 30 Seconds | No.14 | 40 Seconds | No15 | 60 Seconds | Operation Temperature | -10°C ~+ 40°C | Power Source | 100- 120 VAC or 220 -240VAC; 50/60 Hz (Supplied AC mains transformer depends on country requirements) | Power Consumption | 10W | Weight(SET) | 5.7Kg/12.6Ib | Dimension(SET) | 482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in | ※ Specifications and design subject to change without notice. | | | |
|
Reviews
There are no reviews yet.