BIAMP MDS-INT Interface and PSU

No longer available!

248.00 incl. GR VAT

Out of stock

CompareAdd to wishlist Submit Better Price
Availability: No longer available! No longer available! SKU: H06AP00031 Category:
The BIAMP MDS microphone discussion system is a highly flexible small to medium size tabletop discussion system. This easy to set up and to easy to use audio system is the perfect solution for meeting rooms, board rooms and medium conference rooms. This discussion system consists of a chairman unit (MDS.CHAIR) and up to 19 […]

 

Read more

The BIAMP MDS microphone discussion system is a highly flexible small to medium size tabletop discussion system. This easy to set up and to easy to use audio system is the perfect solution for meeting rooms, board rooms and medium conference rooms. This discussion system consists of a chairman unit (MDS.CHAIR) and up to 19 delegate units (MDS.DEL). The connection interface (MDS.INT) is located at the beginning of the microphone chain.

This MDS system has a unique circuit loop design with an easy set-up using standard CAT5 cables for linking up to 20 units in a daisy chain (every microphone and switching adaptor can be located anywhere in the loop). When the chairman presses the mute button, only the chairman unit will be active and all delegates will be muted and deactivated. The delegates can press a button to talk into the flexible gooseneck microphone (no mute function).

The MDS.INT easily connects to any pre-amplifier or matrix with a MIC input with wide gain control (about +20dB of gain needed), allowing you to control the volume and/or use the record output for recording the meeting. Combined with the CMX20T ceiling speakers or MASK4 cabinet loudspeakers, you will have an astonishing voice clarity!

Weight 0.60 kg

Reviews

There are no reviews yet.

Be the first to review “BIAMP MDS-INT Interface and PSU”

Your email address will not be published. Required fields are marked *

Quick Comparison

BIAMP MDS-INT Interface and PSU removeAKG CS 2BU Base Station for up to 200 Microphone Stations removeTOA TS-901 Chairman Unit removeTOA TS-900 Central Unit removeAKG CS 5 IRT1 INFRARED TRANSMITTER SMALL removeAKG CS-5 BU BASE UNIT Digital Conference System remove
NameBIAMP MDS-INT Interface and PSU removeAKG CS 2BU Base Station for up to 200 Microphone Stations removeTOA TS-901 Chairman Unit removeTOA TS-900 Central Unit removeAKG CS 5 IRT1 INFRARED TRANSMITTER SMALL removeAKG CS-5 BU BASE UNIT Digital Conference System remove
Imagecs_2bu_b Base Station akg
SKUH06AP00031CS 2BUTS-901TS-900CS 5 IRT1CS 5 BU 19COL
Rating
Price 248.00 incl. GR VAT 894.99 incl. GR VAT 356.00 incl. GR VAT 1,042.00 incl. GR VAT 2,400.00 incl. GR VAT 3,600.00 incl. GR VAT
Stock

Out of stock

In stock

In stock

In stock

Available on backorder

Available on backorder

AvailabilityOut of stockIn stockIn stockIn stockAvailable on backorderAvailable on backorder
Add to cart

Read more

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description
ContentThe BIAMP MDS microphone discussion system is a highly flexible small to medium size tabletop discussion system. This easy to set up and to easy to use audio system is the perfect solution for meeting rooms, board rooms and medium conference rooms. This discussion system consists of a chairman unit (MDS.CHAIR) and up to 19 delegate units (MDS.DEL). The connection interface (MDS.INT) is located at the beginning of the microphone chain. This MDS system has a unique circuit loop design with an easy set-up using standard CAT5 cables for linking up to 20 units in a daisy chain (every microphone and switching adaptor can be located anywhere in the loop). When the chairman presses the mute button, only the chairman unit will be active and all delegates will be muted and deactivated. The delegates can press a button to talk into the flexible gooseneck microphone (no mute function). The MDS.INT easily connects to any pre-amplifier or matrix with a MIC input with wide gain control (about +20dB of gain needed), allowing you to control the volume and/or use the record output for recording the meeting. Combined with the CMX20T ceiling speakers or MASK4 cabinet loudspeakers, you will have an astonishing voice clarity!
  • Base Station for up to 200 Microphone Stations
  • Intuitive controls
  • Superior audio quality
  • Voice activation and NOM limitation
  • Standard ins and outs for external equipment
The CS 2 Base Station controls up to 200 Microphone Stations and provides automatic NOM (Number of Open Microphones) attenuation. System gain will decrease by approx. 3 dB every time the number of open microphone doubles. The result is a substantially lower risk of feedback even if the number of open microphones varies constantly. A selectable Voice Activation function turns the microphones on automatically as soon as they are talked into. The NOM Limitation function allows the number of simultaneously open microphones to be limited to one, two, three, four, or five. This function can be locally disabled on each Microphone Station so a specific microphone, e.g., one mounted on a lectern, will come on every time, no matter how many mics may be open already.
  • System Features and Outline
  • Bilingual conference system. Either English interpretation (main audio) or Japanese interpretation (sub audio) is selectable for monitoring.
  • Operations such as giving speech permission can be done from the operation PC. *Custom design.
  • The number of conference units can be set for any of one, two or four persons allowed to talk at a time.
  • All speeches during the conference can be recorded clearly.
  • Sub audio(Japanese interpretation) is not recorded.
  • Threefold choice vote function enables the voting just at the press of a Vote key on each unit. The result can be instantly totalized on the Central unit.
  • Speeches can be addressed to audience via sound amplification. * The sub audio output is not amplified

SPECIFICATION:

Power Source 7.4 V DC (battery), 9 V DC (AC adapter)
(supplied from BP-900 battery (option) or AD-0910 AC adapter (option))
Current Consumption MAX. 270 mA
Wavelength 870 nm (AM: Brightness modulation)
Modulation Method Frequency modulation
Carrier Frequency Transmission: Audio channel 1: 7.35 MHz
Audio channel 2: 8.10 MHz
Audio channel 3: 8.55 MHz
Audio channel 4: 9.15 MHz
Control channel: 6.45 MHz
Reception: Base language channel: 1.95 MHz
Translation language channel: 2.25 MHz
Acceptance Angle Vertical: 90°, Horizontal: 120°
Emission Angle Vertical: 90°, Horizontal: 120°
Covering Range 7 m (radius)
Input Microphone terminal: Combined type of XLR-4-31 (dedicated for connecting the optional TS-903 or TS-904)
Output Monitor speaker: 8Ω, 0.2 W
Headphone: Mini jack × 2
LED Indicator Speech indicator (flashes when the unit is out of communications range),Voting status indicators 1 -3 (flashes when the unit is out of communication range or when the battery level is low), Power indicator (flashes when the unit is out of communications range or when the battery level is low)
Battery Life Approx. 10 hours (when the fully-charged BP-900 battery is used with "During Speech" to "Standby" ratio of 1:2)
Operating Temperature 0º to+40º
Finish Top panel: ABS resin, gray metallic, paint, semi-gloss
Dimensions 210(W )×65.9(H )×152(D )mm
Weight 640g
Option Lithium-ion battery: BP-900 AC adapter: AD-0910

 

  • System Features and Outline
  • Bilingual conference system. Either English interpretation (main audio) or Japanese interpretation (sub audio) is selectable for monitoring.
  • Operations such as giving speech permission can be done from the operation PC. *Custom design.
  • The number of conference units can be set for any of one, two or four persons allowed to talk at a time.
  • All speeches during the conference can be recorded clearly.
  • Sub audio(Japanese interpretation) is not recorded.
  • Threefold choice vote function enables the voting just at the press of a Vote key on each unit. The result can be instantly totalized on the Central unit.
  • Speeches can be addressed to audience via sound amplification. * The sub audio output is not amplified

SPECIFICATIONS:

Power Source 100-240 V AC, 50/60Hz (supplied from AC adapter (accessory))
Power Consumption 72W
Input MIC: -60 dB*, 600O,unbalanced, phone jackAUX: -20 dB*, 10 kO,unbalanced, phone jack
Output REC: -20 dB*, 10 kΩ, unbalanced, phone jack, RCA pin jack HEADPHONE: Mini jack
Number of Connectable Chairman/Delegate Units 64 units
Number of Connectable Infrared Transmitter/Receiver Units 4 units (up to 16 units by using four Distributors)
Infrared Transmitter/Receiver I/O Terminal 4 BNC jacks
External Control Terminal D-sub connector (9 P, male)
LED Indicator Voting result indicators 1-3 (7-segment LED, double-digit number), Audio signal receiving indicators 1-4 CH, Data signal receiving indicator, External control priority indicator, External control communication indicator, Power indicator, Battery indicator (flashes when a Chairman/Delegate unit's battery nears complete discharge)
Function Switch Simultaneous speaker No. setting switch: 1/2/4 Mic-off setting switch: TIME OUT ON/OFF
Speech priority selector switch: A/B/C (A: First-in-first-out priority, B: Last-in-first-out priority, C: Fixed for the first unit, and last-in-first-out for the subsequent units)
Microphone Mix/Cut Switch (for the Base Language) MIC/CUT (Mix): Chairman/Delegate units + MIC 1+ AUX 1 +AUX 3 → Base Language (Cut): MIC 1 + AUX 1 + AUX 3→ Base Language
Microphone Mix/Cut Switch (for the Translation Language) MIC/CUT (Mix): Chairman/Delegate units + MIC 2 + AUX 2 + AUX 3 → Translation Language (Cut): MIC 2 + AUX 2 + AUX 3→Translation Language
AUX 3 Mixing Select Switch MIC/CUT (Mix): AUX 3 input is relayed to the line output. (Cut): AUX 3 input is not relayed to the line output.
Operating Temperature 0º to+40º
Finish Panel: Surface-treated steel plate, gray metallic, paint, semi-gloss
Weight 2.7kg
Accessory AC adapter (Cord length: 1.8 m DC cord, and 2 m detachable AC cord)…1
Option Rack mounting bracket: MB-TS900
  *0dB=1V

 

Infrared radiators providing wireless transmission of up to seven language channels for persons (e.g., observers) listing to a conference without asking for the floor.

The infrared radiators shall connected to the CS 5 BU through 2 BNC connectors and 50 Ohm coaxial cabling and serial concatenation. It shall transmit a  PPM system modulated time-multiplex outputs of the central unit shall drive an arbitrary number of radiators. The CS 5 IRT1 shall have a radiation angle of +/- 22° and a working distance of 300 meters (with 50% down). The CS 5 IRT2 shall have a radiation angle of +/- 22° and a working distance of 500 meters (with 50% down).

As accessories of the infrared radiators the holding frame needed for mounting it to the side wall or the ceiling shall be included. The transmitter shall have a built in switchable power supply with IEC connector.

 

 

  • Digital controller for any size systems
  • Ease of use
  • Complete with all inputs and outputs needed for complex systems
  • Integrated infrared signal output
  • Free basic control software included

The CS 5 BU ensures easy, user-friendly control of everything from a small discussion setup to a large conference system. The Base Unit provides all the inputs and outputs needed to manage a complex audio system. It controls 64 audio channels that can be individually programmed and assigned to interpretation channels or NOM limitation.

To ensure maximum reliability, all microphone stations and interpreter stations are „daisy-chained" together and connected back to the Base Unit, forming a closedcircuit digital audio bus. Thus, the entire system will continue operating perfectly, with no interruption, even if one of the bus cables breaks.

To power the system, a CS 5 PS 12 power supply is connected to every twelfth microphone station, ensuring consistent signal levels. Unlike competitive techniques, AKGʼs approach to keeping consistent signal levels throughout the system is uncommonly cost efficient. Every CS 5 Conference System comes complete with a FREE basic control software package so the entire system can be controlled from a computer from day one.

The Base unit shall operate up to 5000 units. As analogue inputs the base unit shall handle an external microphone for easy translating to be routed to channel 1, an ordinary external microphone, telephone in and out with mix minus sum, tape in and out and Line in and out. The infrared modulation shall be included in the base unit, providing the relevant infrared signal on two BNC connectors. Also included in the base unit shall be a USB connector to connect to a PC. A basic software package for participants database, voting and other basic functions shall be included. The unit shall be 1 HU 19” wide in a rack mount housing. A serial port shall be available to enable AMX control.

 

 

Weight0.60 kg3.00 kg0.64 kg2.70 kg10.00 kg4.00 kg
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Weight 0.60 kg
Weight 3.00 kg
Weight 0.64 kg
Weight 2.70 kg
Weight 10.00 kg
Weight 4.00 kg