Content |
Infrared thermometer introduction: ①fever reminder, guard your baby\'s health ②Infrared temperature measurement technology Avoid contact with baby skin and spread bacteria ③Large back lit display (multi-parameter display) ④50 groups of memory functions °C/°F switching function / low battery reminder function ⑤2 temperature measurement mode Object temperature, body temperature measurement mode switch, 3-color back light display different temperature display different colors. ⑥Measurement result reminder: At the end of the measurement, the speaker will make a sound, prompting to complete the measurement. ⑦Precision temperature probe German precision probes ensure accurate temperature measurement ⑧Low power consumption, energy saving and envirronmental protection Powerred by 2 AAA batteries, no measurement 30 S automatic shutdown.
Display: LCD Digital
Way of working: Infrared
Alarm function: Three-color alarm
Operating mode: Human body and objects
shape: Handheld Gun shape
Battery voltage: DC 3 V (2 AAA alkaline batteries)
Measuring range: 34.0 ℃ ~ 43.0 ℃
Measurement accuracy: 42.0 ℃: ± 0.3 ℃ 35.0 ° C to 42.0 ° C: ± 0.2 ° C
Measuring distance: 5 ~ 15 cm
Measurement interval: about 6 seconds
Three-color back light Surface temperature mode:
Below 37.5 ℃ is green
37.6 ° C to 38.0 ° C is yellow
38.1 ℃ above is red
Automatic shutdown: ≦ 20 seconds
Storage: -20 ℃ ~ 45 ℃, relative humidity: ≦ 85% | Tests XLR, 1/4 in., 1/8 in., TT, RCA and MIDI connectors.
The intelligent, CPU-controlled CT100 accepts virtually any connector type:
XLR, mono and TRS phone (1/4 in., 1/8 in., TT), RCA and MIDI. It shows
which input pin is connected to which output pin. Separate LEDs indicate
proper shield connection and phantom power presence. The CT100 also
offers an installed cable test mode and a continuity check plus a test tone
generator.
Features
3 modes: cable test mode, installed cable test mode, and test tone mode
Accepts XLR, mono and stereo TRS phone (1/4 in., 1/8 in., TT),
RCA and MIDI Connectors
Continuity check
Intermittent detect
Phantom power detect
Grounded shield detect
Test tone generation (1 kHz and 440 Hz)
Battery operation (requires 2 AA alkaline batteries) | With the PAN05, two microphone signals can be mixed down to one. Since decoupling occurs via the balanced resistor network, the PAN05 also lets phantom power "pass through“, useful for condenser microphones. However, due to the difference in sound and signal level, mixing dynamic and condenser mics should be avoided. Best results will be achieved using two identical mics.
SPECIFICATIONS:
- Input: 2 x XLR/f balanced
- Nominal impedance: 200 Ω
- Output 1 x XLR/m balanced
- Load impedance >200 Ω
- Symmetrically decoupled through resistors
- Total ohmic value: 200 ohms
- Typical attenuation: 6 dB
- Housing: metal casing 110 x 73 x 42 mm
|
- Microprocessor-controlled cable tester featuring 3 modes: cable and installed cable test plus test tone mode
- Accepts all standard connectors: XLR, Speakon*, TRS (1/4“, 1/8“), RCA, RJ45, MIDI and USB
- Super-easy operation with intuitive LED display
- Continuity check and intermittent contact detection
- Phantom-power and ground-shield check
- Test-tone generator: 1 kHz or 440 Hz at +4 dBu, -10 dBV or -50 dBV
- Operates with 2 AA size batteries (not included)
- Designed and engineered in Germany
|
ACOUSTILYZER
The Acoustilyzer AL1 functionality complements and expands the ML1
Minilyzer with a new and comprehensive set of acoustical measurement
functions.
The optimized combination of electrical and acoustical features creates
the perfect all in one tool for sound/systems contractors, installers and
multi-media specialists. The Acoustilyzer AL1 is available as a palm-sized
portable acoustical analyzer or as firmware for Minilyzer owners with optional
available STI-PA measurement functionality.
Required Accessories:
The AL1 requires a measurement microphone for acquiring acoustical signals.
NTI offers the following microphones:
- MiniSPL, class 2 acc. IEC 61672
- M2010, class 1 frequency response (ext. phantom power supply required)
Product Details
Sound Pressure Level: Leq, short-time Leq , LE, Lmin, Lmax,
Real Time Analyzer: 1/1 or 1/3 octave band resolution SPL/LEQ display per
band, max - min display
Zoom FFT: Actual level and Leq, full band up to 0.7Hz resolution
Reverberation Time: RT60 with 1/1 octave band resolution, confidence indicator,
according to ISO3382
Delay Time: Propagation delay between electrical and acoustical signal (built in mic),
resolution: 0.1ms
STI-PA (optional): Single value STI or CIS test result, modulation indices display,
individual band level results, error indicator, amplitude weighting acc. IEC 60268-16
release 2003
Electrical: Level RMS, THD+N, Polarity
Measurement microphone: Required for acquiring acoustical signals, NTI offers MiniSPL
or M2010 measurement microphones
|
- Measures impedance of speaker lines up to 100k ohms
- Batteries: four (AA)
- Zero adjustment for accuracy on all ranges
- Easy to read meter calibrates directly in ohms
- Includes carrying case, test leads and impedance to power reference chart
- Five year warranty
|
Reviews