Content |
Infrared thermometer introduction: ①fever reminder, guard your baby\'s health ②Infrared temperature measurement technology Avoid contact with baby skin and spread bacteria ③Large back lit display (multi-parameter display) ④50 groups of memory functions °C/°F switching function / low battery reminder function ⑤2 temperature measurement mode Object temperature, body temperature measurement mode switch, 3-color back light display different temperature display different colors. ⑥Measurement result reminder: At the end of the measurement, the speaker will make a sound, prompting to complete the measurement. ⑦Precision temperature probe German precision probes ensure accurate temperature measurement ⑧Low power consumption, energy saving and envirronmental protection Powerred by 2 AAA batteries, no measurement 30 S automatic shutdown.
Display: LCD Digital
Way of working: Infrared
Alarm function: Three-color alarm
Operating mode: Human body and objects
shape: Handheld Gun shape
Battery voltage: DC 3 V (2 AAA alkaline batteries)
Measuring range: 34.0 ℃ ~ 43.0 ℃
Measurement accuracy: 42.0 ℃: ± 0.3 ℃ 35.0 ° C to 42.0 ° C: ± 0.2 ° C
Measuring distance: 5 ~ 15 cm
Measurement interval: about 6 seconds
Three-color back light Surface temperature mode:
Below 37.5 ℃ is green
37.6 ° C to 38.0 ° C is yellow
38.1 ℃ above is red
Automatic shutdown: ≦ 20 seconds
Storage: -20 ℃ ~ 45 ℃, relative humidity: ≦ 85% | Overview:
This is an infrared digital forehead thermometer with high precision, which is hand-held and portable for easy use. Non-contact design reduces cross infection effectively, widely used for measuring body temperature.
Features:
High precision infrared sensor, stable and reliable, for safe use, ensures accurate measuring, small error.
Alarm temperature can be set and once exceeded, it will give out a beep sound. Also, it supports the Mute mode.
Humanized design, LCD screen display with high brightness backlight can clearly show the body temperature.
Aim at the forehead (3-5cm), press the measuring button, and the LCD display will show the currently measured temperature.
Automatic store 32 sets of measurement data, you can view the data of the previous measurement.
Short press the Function Setting button to switch between Body and Object temperature modes.
Compact design, lightweight and portable, comfortable grip handle, easy to carry, convenient to use.
Suitable for baby, kids, and adult use and can be widely used in school, office, and at home, etc.
Note: The battery is not included.
Specification:
Model: ZK-YK1028
Measuring Method: Non-Contact
Measuring Distance: 3cm-5cm
Unit of Measurement: Celsius(℃), Fahrenheit(°F)
Measuring Range: 32℃-42.9℃ (89.6°F-109.2°F)
Max. Allowable Error: ±0.3℃ within range 35℃-42℃
Display Resolution: 0.1℃/0.1°F
Operating Environment: 16℃-35℃ (60.8°F-95°F), Humidity≤85%
Transportation Storage Environment: -20℃-50℃ (-4°F-131°F), Humidity ≤90%
Power: DC 3V (2 AAA Batteries Not Included)
Backlight: Highlight Backlight
Automatic Shut-down: 30s
Item Size: 15.0 * 8.5 * 4.3cm / 5.90 * 3.34 * 1.69in
Item Weight: 105g / 3.70oz
Package Size: 17.0 * 10.5 * 4.8cm / 6.69 * 4.13 * 1.89in
Package Weight: 156g / 5.50oz
Package List:
1 * Thermometer
1 * User Manual (English)
|
The MiniSPL is the perfect accessory to the Acoustilyzer & Minilyzer for
acoustical measurements.
The MiniSPL is a battery powered measurement microphone. Together
with the Acoustilyzer or Minilyzer, it forms an acoustical analyzer and integrating
sound level meter. Additionally it may be operated as a stand-alone microphone
e.g. connected to a balanced audio-line, a microphone-input or a sound-card.
Product-details
? Battery powered
? Factory-set sensitivity
? No phantom power required
? 1/2" microphone, class 2 acc. IEC 61672
? Omni-directional
? Supplied with mic clamp, wind protection
? Typical frequency response included
MiniSPL together with Acoustilyzer:
? SPL Meter / RTA
? Reverberation Time RT60
? Delay Time
? FFT Analyzer
? Speech Intelligibility STI-PA
MiniSPL together with Minilyzer:
? Measurements: SPL, min./max., Leq
? 1/3rd octave spectrum analyzer |
Digilyzer? DL1
Digital audio analyzer / audio meter with integrated speaker, audio lens and a
comprehensive event logger. Digital audio becomes simple by using the Digilyzer DL1.
The digital audio meter Digilyzer DL1 provides a comprehensive set of analysis
functions for digital, audio and video related audio signals.
It handles virtually all digital audio formats including ADAT and sampling frequencies
up to 96 kHz. The simple and intuitive operation allows the user to monitor, analyze
and troubleshoot any digital signals.
Debugging of digital audio signals becames easy with the assistance of the Digilyzer:
Features like the integrity check, the integrated speaker with audio lens function, the
logging functions, the ?over all? view of all important parameters and many more functions
to allow you to understand whats going on and finding faults easier than ever.
The Digilyzer is a handheld, battery powered device with optional mains power supply and
optional USB interface called MiniLINK.
MiniLINK, the USB interface for the Digilyzer allows documentation and data acquisition of
all DL1 functions in conjunction with the easy to use MiniLINK PC application. MiniLINK
supports online data logging up to several days. Read more about MiniLINK.
Product-details
? AES3, S/PDIF, TOS-Link
? ADAT Interface
? Sampling Frequency 32-96 kHz
? Digital Audio Analysis
? Carrier Status Analysis
? Carrier Signal Measurement
? Dual Domain Monitor Speaker
? Comprehensive Event Logger
| RS232 Digital Sound Level Meter 8921/8922
- Deluxe super large LCD display w/ affordable price
- Meet IEC60651, type2 class standard
- Unique background noise absorber
- Features w/digital display and analog bar graph
- Professional and rigid design
- Auto / manual ranging ,6 measurement ranges in 10 steps
- Max hold
- Record max / min
- Fast / Slow response mode is selectable
- A /C weighting is selectable
- Easy to calibrate by standard calibrator
- AC/DC analog output
- Tripod mountable
- Backlight function to use in dark area (8922only)
SPECIFICATIONS
Measure range A weight: 30dB~130dB
C weight: 35dB~130dB
Digital display (6 ranges) 30~80, 40~90, 50~100, 60~110, 70-120, 80-130dB
Digital display resolution 0.1dB
Digital updating time 160mS
Quasi-analog bar (6 ranges) 30~80, 40~90, 50~100, 60~110, 70-120, 80-130dB
Quasi-analog bar resolution 1dB
Bar updating time 40mS
Accuracy at 94dB, 1KHz +/-1.5dB
Analog output Microphone AC 0.707Vrms(at full scale); DC 10mV/dB
Dia.6mm electric condenser microphone
Frequency range 31.5Hz~8KHz
Battery life time 30 hours typical
Windscreen LCD YES
size (mm) 42(H)x62(W)
Operating temp. 0~50oC
Operating RH% Humidity
Storage temp. -20~50oC
Storage RH% Humidity
Dimension(mm) Weight 254x77x37
Battery 9V battery x 1pc or 9VDC adaptor
Standard Package Meter/Battery/Manual/carry case
Optional Accessory Computer connection software kit
- DIGITAL DISPLAY WITH ANALOG GRAPH!
- BACKGROUND NOISE ABSORBER !
- BACKLIGHT FOR DARK AREA OPERATION!
- MAX / MIN RECORD, MAX HOLD !
- RS232 INTERFACE !
- MEETS IEC 651, TYPE 2 CLASS !
| With the PAN05, two microphone signals can be mixed down to one. Since decoupling occurs via the balanced resistor network, the PAN05 also lets phantom power "pass through“, useful for condenser microphones. However, due to the difference in sound and signal level, mixing dynamic and condenser mics should be avoided. Best results will be achieved using two identical mics.
SPECIFICATIONS:
- Input: 2 x XLR/f balanced
- Nominal impedance: 200 Ω
- Output 1 x XLR/m balanced
- Load impedance >200 Ω
- Symmetrically decoupled through resistors
- Total ohmic value: 200 ohms
- Typical attenuation: 6 dB
- Housing: metal casing 110 x 73 x 42 mm
|
Reviews