Content | Non-Contact Laser Thermometer LCD Digital IR Infrared Thermometer GM400 Temperature Meter Gun Point -50~400 Degree
This infrared thermometer USES non-contact infrared sensing technology, the target of safety, preparation, fast, reliable measurement, is widely used in measuring the mechanical, chemical, ceramics, light industry, food, metallurgy, electric power, high temperature heat treatment and other industries, dangerous and difficult to close to the surface temperature measurement. Temperature measurement is widely used in the school laboratory and home.
Objects of any temperature greater than absolute zero radiation infrared energy, this energy to around at the speed of light transmission, infrared lens collects and gathers the infrared energy to the sensor, the sensor produces a low output voltage, the voltage is proportional to the temperature of the target object, voltage after processing for the temperature value.
- Not recommended for human use.
Main features:
1. Temperature range: -50 ℃ ~ 400 ℃ (-58 ℉ ~ 752 ℉)
2. Accuracy: ± 1.5 ° C (± 2.7 ° F) OR ± 1.5% ° C
3. ℃ / ℉ conversion selection function
4. Display resolution: 0.1 ℃ or 0.1 ℉
5. Working environment: 10 ℃ - ~ 40 ℃ (50 ℉ ~ 104 ℉), relative humidity: 10 ~ 90RH no condensation
6. Storage temperature: -10- ~ 40 ℃ (14 ℉ ~ 104 ℉)
7. Detection time: ≤ 0.8second
8. Distance coefficient ratio: 12: 1 (distance and measuring point size ratio)
9. Emissivity: Preset: 0.95
10. Power supply: 2 7 batteries (purchase, replace the battery more convenient)
11. Battery life of about 12 hours
12.LED backlight (easy to use at night)
13. Automatic shutdown function (about 10 seconds)
Model |
INFRARED THERMOMETER-GM400 |
Temperature range |
-50 ℃ ~ 400 ℃ (-58 ℉ ~ 752 ℉) |
Accuracy |
± 1.5 ° C (± 2.7 ° F) OR ± 1.5% ° C |
Display resolution: |
0.1 ℃ or 0.1 ℉ |
Working environment |
10 ℃ - ~ 40 ℃ (50 ℉ ~ 104 ℉), relative humidity: 10 ~ 90RH no condensation |
Storage temperature |
-10- ~ 40 ℃ (14 ℉ ~ 104 ℉) |
Detection time |
≤ 0.8second |
Distance coefficient ratio |
12: 1 (distance and measuring point size ratio) |
Emissivity Preset: |
0.95 |
Power supply |
2 7 batteries (purchase, replace the battery more convenient) |
Battery life |
12 hours |
LED |
LED backlight |
Automatic shutdown function |
about 10 seconds |
| Tests XLR, 1/4 in., 1/8 in., TT, RCA and MIDI connectors.
The intelligent, CPU-controlled CT100 accepts virtually any connector type:
XLR, mono and TRS phone (1/4 in., 1/8 in., TT), RCA and MIDI. It shows
which input pin is connected to which output pin. Separate LEDs indicate
proper shield connection and phantom power presence. The CT100 also
offers an installed cable test mode and a continuity check plus a test tone
generator.
Features
3 modes: cable test mode, installed cable test mode, and test tone mode
Accepts XLR, mono and stereo TRS phone (1/4 in., 1/8 in., TT),
RCA and MIDI Connectors
Continuity check
Intermittent detect
Phantom power detect
Grounded shield detect
Test tone generation (1 kHz and 440 Hz)
Battery operation (requires 2 AA alkaline batteries) |
Palmer Pro MCT DMX 3-pin and 5-pin DMX and XLR cable tester
MCT DMX
This cable tester checks 3-pin and 5-pin DMX cables for continuity in fully automatic or manual pin selection modes. Pin connection status of the male and female cable ends is indicated by two rows of bright LEDs. In addition, the unitʼs 3-pin connectors can also be used to test XLR microphone cables. The DMX Cable Tester comes with two L-brackets for variable mounting options.
- Tests 3-pin and 5-pin DMX cables for continuity
- Also tests 3-pin XLR microphone cables
- Automatic test mode or manual pin 1 - 5 selection
- LED indicators
- Mounting brackets included
Product type
Test Equipment
Connectors
XLR (3-pin) , XLR (5-pin)
Controls
Auto Scan , On / Off , Scan switch
Indicators
LED chain
Operating voltage
2 x AA battery
Acoustic continuity test
no
Test cable
no
Cabinet material
sheet steel
Cabinet surface
powder coated
Width
240.2 mm
Height
48 mm
Depth
53 mm
Weight
0,7 kg
|
Infrared thermometer introduction: ①fever reminder, guard your baby\'s health ②Infrared temperature measurement technology Avoid contact with baby skin and spread bacteria ③Large back lit display (multi-parameter display) ④50 groups of memory functions °C/°F switching function / low battery reminder function ⑤2 temperature measurement mode Object temperature, body temperature measurement mode switch, 3-color back light display different temperature display different colors. ⑥Measurement result reminder: At the end of the measurement, the speaker will make a sound, prompting to complete the measurement. ⑦Precision temperature probe German precision probes ensure accurate temperature measurement ⑧Low power consumption, energy saving and envirronmental protection Powerred by 2 AAA batteries, no measurement 30 S automatic shutdown.
Display: LCD Digital
Way of working: Infrared
Alarm function: Three-color alarm
Operating mode: Human body and objects
shape: Handheld Gun shape
Battery voltage: DC 3 V (2 AAA alkaline batteries)
Measuring range: 34.0 ℃ ~ 43.0 ℃
Measurement accuracy: 42.0 ℃: ± 0.3 ℃ 35.0 ° C to 42.0 ° C: ± 0.2 ° C
Measuring distance: 5 ~ 15 cm
Measurement interval: about 6 seconds
Three-color back light Surface temperature mode:
Below 37.5 ℃ is green
37.6 ° C to 38.0 ° C is yellow
38.1 ℃ above is red
Automatic shutdown: ≦ 20 seconds
Storage: -20 ℃ ~ 45 ℃, relative humidity: ≦ 85% |
ACOUSTILYZER
The Acoustilyzer AL1 functionality complements and expands the ML1
Minilyzer with a new and comprehensive set of acoustical measurement
functions.
The optimized combination of electrical and acoustical features creates
the perfect all in one tool for sound/systems contractors, installers and
multi-media specialists. The Acoustilyzer AL1 is available as a palm-sized
portable acoustical analyzer or as firmware for Minilyzer owners with optional
available STI-PA measurement functionality.
Required Accessories:
The AL1 requires a measurement microphone for acquiring acoustical signals.
NTI offers the following microphones:
- MiniSPL, class 2 acc. IEC 61672
- M2010, class 1 frequency response (ext. phantom power supply required)
Product Details
Sound Pressure Level: Leq, short-time Leq , LE, Lmin, Lmax,
Real Time Analyzer: 1/1 or 1/3 octave band resolution SPL/LEQ display per
band, max - min display
Zoom FFT: Actual level and Leq, full band up to 0.7Hz resolution
Reverberation Time: RT60 with 1/1 octave band resolution, confidence indicator,
according to ISO3382
Delay Time: Propagation delay between electrical and acoustical signal (built in mic),
resolution: 0.1ms
STI-PA (optional): Single value STI or CIS test result, modulation indices display,
individual band level results, error indicator, amplitude weighting acc. IEC 60268-16
release 2003
Electrical: Level RMS, THD+N, Polarity
Measurement microphone: Required for acquiring acoustical signals, NTI offers MiniSPL
or M2010 measurement microphones
|
- Measures impedance of speaker lines up to 100k ohms
- Batteries: four (AA)
- Zero adjustment for accuracy on all ranges
- Easy to read meter calibrates directly in ohms
- Includes carrying case, test leads and impedance to power reference chart
- Five year warranty
|
Reviews
There are no reviews yet.