Content |
Designed to plug directly into a panel- or desk-mounted XLRF-type connector, the U859QL features an ultra-flexible small-diameter gooseneck and a fixed cardioid element. Equipped with self-contained electronics, the phantom-powered microphone also offers an 80 Hz low-cut UniSteep® filter that reduces pickup of low-frequency ambient noise. The microphone is 480.0 mm long.
- Designed for high-quality sound reinforcement, professional recording and broadcasting
- Superior off-axis rejection for maximum gain before feedback
- Easy-to-adjust, rugged, small-diameter, alternating gooseneck with virtually no 'memory' permits quick positioning into desired shape
- UniSteep® filter provides a steep low-frequency attenuation to improve sound pickup without affecting voice quality
- Self-contained electronics eliminate need for external power module
- Quick-mount design with 3-pin XLRM-type connector insert at base plugs into any standard XLRF-type surface or cable connector
- Element: Fixed-charge back plate permanently polarized condenser
- Polar Pattern: Cardioid
- Frequency Response: 100-16,000 Hz
- Low Frequency Roll Off: 80 Hz, 18 dB/octave
- Open Circuit Sensitivity: 43 dB (7.0 mV) re 1V at 1 Pa
- Impedance: 250 ohms
- Maximum Input Sound Level: 140 dB SPL, 1 kHz at 1% T.H.D.
- Dynamic Range: 111 dB, 1 kHz at Max SPL
- Signal to Noise Ratio: 65 dB, 1 kHz at 1 Pa
- Phantom Power Requiremens: 11-52V DC, 2 mA typical
- Switch: Flat, roll-off
- Weight: 5.4 oz (152 g)
- Dimensions: 18.90" (480.0 mm) long, 0.48" (12.3 mm) head diameter, 0.74" (18.9 mm) base diameter
- Output Connector: Integral 3-pin XLRM-type
|
The evolution e 908 instrument microphone is available in four variants:
as e 908 D for drums and percussion
as e 908 B for wind instruments, congas, and drums with free-floating suspension system
as e 908 B ew for the wireless miking of saxophones using an evolution wireless instrument transmitter
as e 908 T ew for the wireless miking of trumpets using an evolution wireless instrument transmitter
Pick-up pattern : cardioid
Frequency response : 40 ... 20 000 Hz
Sensitivity in free field, no load : (1kHz) 4 mV/Pa, 0,56mV/Pa (e 908T-ew)
Equivalent noise level : e908B-ew = 30 dB(A); e908B & e908D = 35 dB(A), e908T-ew = 39 dB (A)
Max. Sound pressure level (aktiv) : 147 dB
Nominal impedance : 100 Ohm (e908B & e908D)
Min. terminating impedance : 2000 Ohm (e908B & e908D)
Phantom powering : 12 - 48 V / 3 mA (e908B & e908D)
Weight : ca. 140 g
Dimensions : Ø 47 x 193 mm
|
Shure MX418D-C Gooseneck Cardioid Condenser Microphone
Microflex? Gooseneck microphones bring a whole new meaning to the word flexible with their fully adjustable gooseneck. Designed for easy replacement and available in cardioid, supercardioid and omnidirectional polar patterns, the interchangeable cartridges offer wide frequency response and accurate sound reproduction for a wide variety of applications such as houses of worship, courtrooms and conference centers. Plus, the condenser cartridges fit every model in the Microflex product line for enhanced convenience and consistent sound.
Microflex Gooseneck microphones are available in four models with a variety of heights and mounting styles to choose from. One model includes a silent mute switch with LED indicator, a Shure Microflex exclusive. And every Microflex Gooseneck features high sensitivity and balanced, transformerless output for maximum resistance to electromagnetic hum and RF interference, even over long cable runs.
Desktop Base with 10 foot Cable, Logic Functions, Programmable Switch and LED Indicator, Snap-Fit Foam Windscreen
Features:
Wide dynamic range and frequency response for accurate sound reproduction across the audio spectrum Interchangeable cartridges provide the right polar pattern for every application Balanced, transformerless output for increased immunity to noise over long cable runs Shock mount provides over 20 dB isolation from surface vibration noise Locking flange mount for permanently securing microphone to lecterns, pulpits, or conference tables Snap-fit foam windscreen Programmable on/off switch and LED on/off indicator (M412D/MX418D) New brighter LED improves visibility under strong ambient lighting M412D/MX418D) Logic input and output terminals for remote control or use with automatic microphone mixers M412D/MX418D) Supplied shock mount for more than 20 dB isolation from surface transmitted noise (MX412SW/MX418SE) Supplied threaded flange mount for permanently securing the microphone to a lectern, pulpit, or conference table (MX412SW/MX418SE)
Microphone Specifications: Frequency Response 50 to 17,000 Hz Output Impedance 180 ohms actual (EIA rated at 150 ohms) Sensitivity (At 1,000 Hz, open circuit voltage*) Cardioid: -35.0 dBV/Pa (17.8 mV) Supercardioid: -33.5 dBV/Pa (21.1 mV) Omnidirectional: -27.5 dBV/Pa (42.2 mV) All values -12 dB at 0 gain; *1 Pascal = 94 dB SPL Maximum SPL (1 kHz at 1% THD, 1 k ohm load) Cardioid: 124.2 dB Supercardioid: 122.7 dB Omnidirectional: 116.7 dB All values +6 dB at 0 gain Equivalent Output Noise (A-weighted) Cardioid: 28.0 dB SPL Supercardioid: 26.5 dB SPL Omnidirectional: 20.5 dB SPL Signal to Noise Ratio (referenced at 94 dB SPL) Cardioid: 66.0 dB Supercardioid: 67.5 dB Omnidirectional: 73.5 dB Dynamic Range at 1 k ohm load 96.2 dB 100 dB at 0 gain Common Mode Rejection 45.0 dB minimum Preamplifier Output Clipping Level (1% THD) -6.0 dBV (0.5 V) -12 dBV at 0 gain Polarity Positive sound pressure on diaphragm produces positive voltage on pin 2 relative to pin 3 of output connector. Power Requirements 11 to 52 Vdc phantom, 2.0 mA Environmental Requirements Operating Temperature Range: -18 to 57 degrees C (0 to 135 degrees F) Relative Humidity: 0 to 95% |
Polar pattern Cardioid
Frequency range 70 to 18,000 Hz
Max. SPL 125 dB (for 1% THD)
Equivalent noise level 73 dB
Impedance =2,000 ohms
Supply voltage 9 to 52 V phantom power to IEC 61938 (DPA adapter integrated)
Powering |
- Hypercardioid polar pattern
- 38 cm long
- 95° pickup angle
- For acoustically difficult environments
- Connects easily via XLR connector
The hypercardioid polar pattern with its narrow 95° pickup angle is suited best for situations where noise typically occurs from all sides (particularly in worship centers), where people talk into the microphone from a greater distance, or where several talkers are grouped side by side. Two different lengths are available. The .exible joint ensures optimum alignment of the gooseneck to any talker position. Several options are available for installation, i.e., stand, tabletop installation, and lockable.
Choosing polar patterns
Selecting the correct polar pattern for installed sound is difficult since it depends on a variety of factors. Of course the acoustics of the room play a key role. For highly reverberant rooms such as worship centers, a hypercardioid polar pattern will be the best choice to avoid high levels of unwanted noise. Correct placement of the loudspeakers is also essential. If the speakers project right at the capsule, a hypercardioid will be your best bet. The most difficult task, however, is trying to judge how the talkers will behave. For talkers who are inexperienced or move around a lot, be sure to choose a cardioid polar pattern for reliable pickup; talkers at a greater distance from the mic will be served best by a hypercardioid.
The microphone shall be a hypercardioid gooseneck microphone. Its pickup angle shall be 95 degrees; frequency range 50 Hz to 19 kHz; sensitivity 12 mV/Pa; max. SPL 125 dB; electrical impedance
Polar pattern |
Hypercardioid |
Frequency range |
50 to 19,000 Hz |
Sensitivity |
12 mV/PA = -38 dBV re 1 V/Pa |
Max. SPL |
125 dB (for 1% THD) |
Equivalent noise level |
|
Signal/noise ratio (A-weighted) |
>73 dB |
Impedance |
=2,000 ohms |
Supply voltage |
English: 9 to 52 V phantom power to IEC 61938 (DPA adapter integrated) |
Powering |
|
Connector |
3-pin male XLR |
Finish |
matte black |
Dimensions |
CGN 99 H/S: 13.5 x 380 mm (0.5 x 15 in.);
CGN 99 H/L: 13.5 x 580 mm (0.5 x 23 in.) |
Net weight |
CGN 99 H/S: 480 g (17 oz.);
CGN 99 H/L: 500 g (17.7 oz.) |
|
- PA microphone with rugged, all-metal body
- Frequency response optimized for intelligibility
- Long useful life even in tough day-to-day usage
- Frequency response tailored to speech use
Rugged, affordable dynamic cardioid gooseneck microphone for general public address and communications use. The DST 99 S provides a frequency response tailored to speech use for optimum intelligibility as well as good offaxis rejection for high gain before feedback and suppression of unwanted ambient noise. The all-metal body ensures a long useful life for the microphone even in tough day-to-day use.
The DST 99 S is mounted on a table stand with an on/off switch and coiled cable with 3-pin XLR connector.
Ticket window, bank counter
Reception desk, restaurant
Houses of worship
Polar pattern cardioid
Frequency range 150-15,000 Hz
Sensitivity 2.2 mV/Pa (-54 dBV)
Max. SPL 133 dB (1% THD)
Equivalent noise level 21 dB-A
Signal/noise ratio (A-weighted) 73 dB
Impedance 530 ohms
Recommended load impedance >2,000 ohms
Connector 3-pin male XLR
Finish matte black
Net weight 805 g (1.8 lbs.)
Shipping weight 1,125 g (2.5 lbs.)
|
Reviews
There are no reviews yet.