DBX ZC-4 Driverack Wall-Mounted Zone Controller

78.12 incl. GR VAT

In stock

EAN: N/A
Installments calculation
CompareAdd to wishlist Submit Better Price
The Zone Controllers offer extended utility to the DriveRack®and ZonePro families. The nine Zone Controllers use analog DC voltage to provide logic control ranging from zone source selection, volume and muting, to program or scene selection and fire safety muting. Wired with readily available and affordable CAT5 cable with universally accepted rj-45 connectors at distances […]

 

Read more

The Zone Controllers offer extended utility to the DriveRack®and ZonePro families. The nine Zone Controllers use analog DC voltage to provide logic control ranging from zone source selection, volume and muting, to program or scene selection and fire safety muting. Wired with readily available and affordable CAT5 cable with universally accepted rj-45 connectors at distances up to 1000 ft, the ZC Zone Controllers offer simple yet elegant solutions to the contractor.

The ZC-1 provides programmable remote volume control for the DriveRack 260, 220i and the ZonePro 640 and 641. The ZC-2 offers programmable volume and mute control for the DriveRack 220i, 260 and the ZonePro 640 and 641. The ZC-3 can function as a program selector for the DriveRack 260 and 220i; in addition it can be used for as a source selector, page steering control, or a scene selector for the ZonePro products. The ZC-4 provides program change capability from contact closures for the DriveRack 220i and 260; it can also provide source selection, page steering, or scene selection for the ZonePro 640 and 641. The ZC-6 is a programmable volume control for the ZonePro 640 and 641. The ZC-7 is a programmable push -to-talk page assignment controller for the ZonePro devices. The ZC-8 provides both programmable source selection and volume control to the ZonePro 640 and 641. The ZC-BOB allows “home run” or parallel wiring to the DriveRack and ZonePro devices. The ZC-FIRE is a dedicated fire safety interface for the ZonePro products that allows selection of either system mute or scene selection upon being triggered by either a relay or control voltage from the fire safety system.

• Programmable Volume Control

• Program or Scene Selection

• Programmable Contact Closure Interface

• Up to 1000 ft. on CAT 5 Cable

• Programmable Push-To-Talk Paging

• Programmable Source Selection

Weight 0.10 kg

Reviews

There are no reviews yet.

Be the first to review “DBX ZC-4 Driverack Wall-Mounted Zone Controller”

Your email address will not be published. Required fields are marked *

Quick Comparison

DBX ZC-4 Driverack Wall-Mounted Zone Controller removeINTER-M PD-658 SUB POWER DISTRIBUTOR removeTOA RM-300MF Fireman's Microphone removeINTER-M RM-8000 Remote Mic Station removeINTER-M ECS-616 EMERGENCY COMBINATION SYSTEM removeINTER-M PB-607 BATTERY CHARGER remove
NameDBX ZC-4 Driverack Wall-Mounted Zone Controller removeINTER-M PD-658 SUB POWER DISTRIBUTOR removeTOA RM-300MF Fireman's Microphone removeINTER-M RM-8000 Remote Mic Station removeINTER-M ECS-616 EMERGENCY COMBINATION SYSTEM removeINTER-M PB-607 BATTERY CHARGER remove
Image
SKUDBX ZC-4PD-658RM-300MFRM-8000ECS-616PB-607
Rating
Price 78.12 incl. GR VAT 178.99 incl. GR VAT 840.00 incl. GR VAT 424.00 incl. GR VAT 604.87 incl. GR VAT 158.00 incl. GR VAT
Stock

In stock

In stock

Available on backorder

In stock

In stock

In stock

AvailabilityIn stockIn stockAvailable on backorderIn stockIn stockIn stock
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description
Content

The Zone Controllers offer extended utility to the DriveRack®and ZonePro families. The nine Zone Controllers use analog DC voltage to provide logic control ranging from zone source selection, volume and muting, to program or scene selection and fire safety muting. Wired with readily available and affordable CAT5 cable with universally accepted rj-45 connectors at distances up to 1000 ft, the ZC Zone Controllers offer simple yet elegant solutions to the contractor.

The ZC-1 provides programmable remote volume control for the DriveRack 260, 220i and the ZonePro 640 and 641. The ZC-2 offers programmable volume and mute control for the DriveRack 220i, 260 and the ZonePro 640 and 641. The ZC-3 can function as a program selector for the DriveRack 260 and 220i; in addition it can be used for as a source selector, page steering control, or a scene selector for the ZonePro products. The ZC-4 provides program change capability from contact closures for the DriveRack 220i and 260; it can also provide source selection, page steering, or scene selection for the ZonePro 640 and 641. The ZC-6 is a programmable volume control for the ZonePro 640 and 641. The ZC-7 is a programmable push -to-talk page assignment controller for the ZonePro devices. The ZC-8 provides both programmable source selection and volume control to the ZonePro 640 and 641. The ZC-BOB allows "home run” or parallel wiring to the DriveRack and ZonePro devices. The ZC-FIRE is a dedicated fire safety interface for the ZonePro products that allows selection of either system mute or scene selection upon being triggered by either a relay or control voltage from the fire safety system.

• Programmable Volume Control

• Program or Scene Selection

• Programmable Contact Closure Interface

• Up to 1000 ft. on CAT 5 Cable

• Programmable Push-To-Talk Paging

• Programmable Source Selection

- SYSTEM POWER CONTROL

It controls the power of the rack system over all working together with the PD-659.

- AC OUTLET TERMINAL

To make the units using AC work, it has an AC outlet terminal for your convenience. AC switched group turn on and off repeatedly every 2 seconds.

PD- 658

AC Outlet

Switched 2000W ⅹ3

Operation Temperature

-10℃~+40℃

Power Source

100-120VAC or 220-240VAC; 50/60Hz

(Supplied AC mains transformer depends on country requirements)

Power Consumption

10W

Weight(SET)

4.6Kg/10.1 Ib

Dimension(SET)

482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in

The RM-300MF Fireman's Microphone is designed for exclusive use with the VM-3000 Series. It is equipped with an emergency activation key, permitting pre-recorded evacuation and alert announcements to be activated, and microphone announcement to be made in emergency situations. By connecting the RM-320F Fireman's Microphone Extension to the RM-300MF, the number of function keys can be expanded. The zone selection or failure acknowledgment function can be assigned to such function keys.

Specification
Power Source 24 V DC (operating range: 15 - 40 V DC, supplied from the VM-3000 system)
Current Consumption 120 mA (RM-300MF), 660 mA (with 3 RM-320F connected)
Frequency Response 200 Hz - 15 kHz
Distortion 1 % or less
S/N Ratio 55 dB or more
Microphone Unidirectional dynamic microphone with talk key, compressor (on/off switchable)
Volume Control Microphone volume control, Buzzer volume control
Connection Cable Main line: Shield CPEV cable (each one pair of Audio line, Data line, Power supply line)
or Category 5 Shielded Twisted-Pair straight cable for LAN (CAT5-STP), M3 screw terminal
Maximum Cable Distance Total 800 m (874.89 yd)
No. of Connectable RM-320F Max. 3 units
Operation Emergency key, Evacuate key, Alert key, Emergency reset key, CPU switch, Reset switch
Indicator Power indicator, Emergency indicator, Communication failure indicator, CPU OFF indicator,
Evacuation announcement indicator, Alert announcement indicator,
Emergency reset indicator, Microphone in-use indicator,
Emergency broadcast equipment in-use indicator
Operating Temperature -5 ℃ to +45 ℃ (23 ゜F to 113 ゜F)
Operating Humidity 5 % to 95 %RH (no condensation)
Finish ABS resin, blueish gray (PANTONE 538 or its equivalent)
Dimensions 200 (W) × 215 (H) × 82.5 (D) mm (7.87" × 8.46" × 3.25“)
Weight 1.1 kg (2.43 lb) (with wall mounting bracket unit)
Accessory Wall mounting bracket unit …1, Wall mounting screw …2

 

- CONVENIENT INSTALLATION AND CONSTRUCTION WITHOUT NEED OF ID SETTING.

- SELECTION OF VARIOUS CHIME BROADCASTINGS FOR MIC BROADCASTING (PRE/POST).

- CONVENIENT PRIORITY BROADCASTING.

- ADOPTION OF OUTPUT SIGNAL LEVEL DISPLAY.

- ADOPTION OF RS-422 COMMUNICATION METHOD TO SUPPORT A LONG DISTANCE.

Audio Output

0dB(Balanced)

Audio Input

Paging & RM MIC & LM MIC

-50dB(Balanced)

BGM(Main & Local)

-10dB(Balanced)

Tone Control

(100Hz & 10kHz)

Paging MIC

± 10dB

Audio Output

± 12dB

Frequency Response

BGM

± 3dB

MIC

± 3dB

S / N

BGM

Better than 75dB

MIC

Batter than 65dB

T.H.D.

BGM

Less than 0.05%

MIC

Less than 0.05%

Priority Control

Paging MIC > DRP > RM1> RM2 > RM3 > RM4 > LM-8000 > Main BGM

Phantom Power

DC 24V

Serial Interface

Communication Speed

9600bps

Communication Distance

Maximum 300m(UTP CAT%)

Operation Temperature

-10℃ ~ +40℃

Power Source

100-120VAC or 220-240VAC; 50/60Hz

(Supplied AC mains transformer depends on country requirements)

Weight(SET)

1.5kg / 3.2lb

Dimensions(SET)

200(W) x 70(H) x 206(D)mm

7.9(W) x 2.8(H) x 8.1(D)in

※ Specifications and design subject to change without notice.

- PRIORITY CONTROL

It controls the priority of emergency, timer, remote1, remote2, main(normal).

- AUTO FIRE SENSOR

The fire alarm will be given automatically to the designated areas by detecting fire sensor input.

- SPEAKER SWITCHING ON EMERGENCY OR NORMAL(MAIN)

You can control the speaker relay on emergency or normal(main) mode by using the speaker switch on front panel.

- DISPLAY STATUS

You can easily check the priority status.

- 2 AND 3 WIRE SPEAKER LINE SYSTEM

You can control the speaker line on the 2 wire system or 3 wire system.

- EXTENSION FUNCTION

You can easily expand by connecting additional ECS-616.

ECS-616

Priority Control

Emergency >Timer > Remote1 > Remote2 > Main

Link in/ out Interface

RS-422(19200bps,Data 8bits,Stop 1bit, Non Parity bit, Start1bit)

Link in/ out interface Distance

1.2 km

Operation Temperature

-10 °C ~+ 40 °C

Power Source

24V DC

Power Consumption

900mA

Weight

4.8Kg/10.6Ib

Dimensions( W x H x D)

482(W)x 88(H) x 380(D) mm / 19(W)x 3.5(H)x 15(D)in

※ Specifications and design subject to change without notice.

- AUTOMATIC CHARGING

Tapered charging circuitry charges your backup batteries without risk of overcharging.

- EASY BATTERY MONITORING

Integrated digital volt meter and digital ampere meter allow you to monitor the status of your batteries.

PB-607

Battery Requirement

24V DC

Starting Current

3A Max.

Charge Complete Voltage

27.3V ±10%

Operation Temperature

-10℃~+40℃

Power Source

100-120VAC or 220-240VAC; 50/60Hz

(Supplied AC mains transformer depends on country requirements)

Power Consumption

130W

Weight(SET)

7Kg/15.4Ib

Dimension(SET)

482(W) x 88(H) x 280(D)mm/19(W) x 3.5(H) x 11(D)in

Weight0.10 kg4.90 kg1.10 kg1.40 kg4.80 kg7.00 kg
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Weight 0.10 kg
Weight 4.90 kg
Weight 1.10 kg
Weight 1.40 kg
Weight 4.80 kg
Weight 7.00 kg