Content | | |
| | 855ENH - COAX MINI RG59/U LSZH DIGITAL VIDEO
COAX [0.6/2.8] MINI RG59/U LSZH CLASSICS PRO
Product Overview
Environmental Space: |
Indoor - Euroclass Dca |
Suitable Applications: |
Low loss HDTV/SDI Digital coax used in critical analog and digital video circuits and high quality applications such as live broadcast in network studios and pre- or post-production facilities; Cable is suitable for indoor and outdoor use |
Physical Characteristics (Overall)
Conductor
Element |
Stranding |
Material |
Nominal Diameter |
Diameter +/- Tolerance |
No. of Coax |
|
Solid |
BC - Bare Copper |
0.65 mm |
0.02 mm |
1 |
` |
|
|
|
|
|
Insulation
Type |
Material |
Nominal Diameter |
Diameter +/- Tolerance |
Dielectric |
FPE - Foamed Polyethylene |
2.9 mm |
0.15 mm |
Outer Shield Material
Type |
Layer |
Material |
Coverage [%] |
Min. Overlap |
Nominal Diameter |
Coverage +/- Tolerance |
Tape |
1 |
Aluminum/Polyester/Aluminum |
|
2 mm |
|
|
Braid |
2 |
TC - Tinned Copper |
90 % |
|
3.45 mm |
5 % |
Outer Jacket Material
Material |
Nominal Diameter |
Diameter +/- Tolerance |
LSZH / FRNC |
4.45 mm |
0.2 mm |
OuterJacket1, Table Note: |
According to EN 50290-2-20 |
Construction and Dimensions
Min Elongation at Breakof Jacket: |
125 % |
Min Tensile Strength of Jacket: |
9 MPa |
Electrical Characteristics
Conductor DCR
Max. Conductor DCR |
Max. Shield DCR |
55 Ohm/km |
17 Ohm/km |
Capacitance
Nom. Capacitance |
Capacitance Tolerance |
53 pF/m |
2 pF/m |
Impedance
Nominal Characteristic Impedance |
Nominal Characteristic Tolerance |
75 Ohm |
3 Ohm |
High Frequency (Nominal/Typical)
Frequency [MHz] |
Nom. Insertion Loss |
1 MHz |
1.7 dB/100m |
3.6 MHz |
2.5 dB/100m |
5 MHz |
2.8 dB/100m |
6 MHz |
3 dB/100m |
7 MHz |
3.2 dB/100m |
10 MHz |
3.7 dB/100m |
12 MHz |
4 dB/100m |
25 MHz |
5.4 dB/100m |
67.5 MHz |
8.3 dB/100m |
71.5 MHz |
8.6 dB/100m |
88.5 MHz |
9.5 dB/100m |
100 MHz |
10 dB/100m |
135 MHz |
11.5 dB/100m |
143 MHz |
11.9 dB/100m |
180 MHz |
13.2 dB/100m |
270 MHz |
16.1 dB/100m |
360 MHz |
18.6 dB/100m |
540 MHz |
22.8 dB/100m |
720 MHz |
26.4 dB/100m |
750 MHz |
26.9 dB/100m |
1000 MHz |
31.3 dB/100m |
1500 MHz |
38.7 dB/100m |
2000 MHz |
45 dB/100m |
2250 MHz |
48 dB/100m |
2500 MHz |
50.8 dB/100m |
3000 MHz |
56.1 dB/100m |
4000 MHz |
65.7 dB/100m |
4500 MHz |
70.2 dB/100m |
Delay
Nominal Delay |
Nominal Velocity of Propagation (VP) [%] |
Velocity of Propagation Tolerance |
400 ns/ft |
84 % |
2 % |
High Freq
Frequency [MHz] |
Min. RL (Return Loss) [dB] |
5 - 1600 MHz |
23 dB |
1600 - 4500 MHz |
21 dB |
Screening
Frequency [MHz] |
Min. Screening Attenuation After Flexing |
30 - 1000 MHz |
85 dB |
1000 - 2000 MHz |
85 dB |
2000 - 3000 MHz |
85 dB |
3000 - 4500 MHz |
80 dB |
Transfer Impedance
Frequency [MHz] |
Transfer Impedance |
5-30 MHz |
Max. 15 mOhm/m |
Voltage
Voltage Rating [V] |
50 V AC |
75 V DC |
Temperature Range
Installation Temp Range: |
-5°C To +50°C |
Storage Temp Range: |
-30°C To +70°C |
Operating Temp Range: |
-30°C To +70°C |
Mechanical Characteristics
Max Recommended Pulling Tension: |
160 N |
Min Bend Radius (W/o Pulling Strength): |
45 mm |
Standards
CPR Euroclass: |
Dca-s1,d1,a1 |
CENELEC Compliance: |
EN 50117-1 and EN 50290-2-20 |
Applicable Environmental and Other Programs
EU RoHS Compliance Date (yyyy-mm-dd): |
2005-01-01 |
Flammability, LS0H, Toxicity Testing
ISO/IEC Flammability: |
IEC 60332-1-2 and IEC 60332-3-24 |
Other Flammability: |
CEI 20-35/1 |
Amount of Halogen acc. to IEC 60754-1 & EN50267-1: |
Zero |
| 3 core (3 x 1694A) RG-6/U type, 18 AWG solid .040" bare copper conductors, gas-injected foam HDPE
insulation, Duofoil? + tinned copper braid shield (95% coverage), overall PVC jacket.
SUITABLE APPLICATIONS :
Suitable Applications: Video Mult.
PHYSICAL CHARACTERISTICS :
CONDUCTOR :
Number of Coax: 3
Total Number of Conductors: 3
RG Type: 6/U
AWG: 18
Stranding: Solid
Conductor Diameter: .040 in.
Conductor Material: BC - Bare Copper
INSULATION :
Insulation Material: Gas-injected FHDPE - Foam High Density Polyethylene
Insulation Diameter: .180 in.
INNER SHIELD :
Inner Shield Material Trade Name: Duofoil?
Inner Shield Type: Tape/Braid
Inner Shield Material:
Layer Number Trade Name Type Material % Coverage (%)
1 Duofoil? Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100
2 Braid TC - Tinned Copper 95
Inner Shield %Coverage: 100 %
INNER JACKET :
Inner Jacket Material: PVC - Polyvinyl Chloride
Inner Jacket Diameter: .275 in.
Inner Jacket Color Code Chart:
Number Color
1 Red
2 Green
3 Blue
OUTER JACKET :
Outer Jacket Material: PVC - Polyvinyl Chloride
OVERALL NOMINAL DIAMETER :
Overall Nominal Diameter: .770 in.
MECHANICAL CHARACTERISTICS :
Operating Temperature Range: -40°C To +75°C
UL Temperature Rating: 60°C
Non-UL Temperature Rating: 75°C
Bulk Cable Weight: 234 lbs/1000 ft.
Max. Recommended Pulling Tension: 207 lbs.
Min. Bend Radius (Install): 8 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE :
APPLICABLE STANDARDS :
NEC/(UL) Specification: CMR
CEC/C(UL) Specification: CMG
AWM Specification: UL Style 1354 (each coax); UL Style 2688 (overall)
EU CE Mark (Y/N): No
EU RoHS Compliant (Y/N): Yes
EU RoHS Compliance Date (mm/dd/yyyy):: 01/01/2004
FLAME TEST :
UL Flame Test: UL1666 Vertical Shaft
SWEEP TEST :
Sweep Testing: Sweep tested 5 MHz to 3 GHz.
SUITABILITY :
Suitability - Indoor: Yes
Suitability - Outdoor: Yes
Suggested Connectors: Kings 2065-10-9 75 Ohm BNC, each coax
PLENUM/NON-PLENUM :
Plenum (Y/N): N
ELECTRICAL CHARACTERISTICS :
Nom. Characteristic Impedance: 75 Ω
Nom. Capacitance Conductor to Shield: 16.2 pF/ft
Nominal Velocity of Propagation: 82 %
Nominal Delay: 1.24 ns/ft
Nom. Conductor DC Resistance @ 20 Deg. C: 6.4 Ω/1000 ft
Nom. Inner Shield DC Resistance:: 3.0 Ω/1000 ft
Minimum Structural Return Loss:
Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Minimum Structural Return Loss (dB)
5 580 23
580 680 15
680 850 23
850 3000 15
Nom. Attenuation:
Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Nom. Attenuation (dB/100 ft.)
1 0.24
3.58 .45
5 .54
7 .63
10 .72
67.5 1.57
71.5 1.60
88.5 1.75
100 1.84
135 2.10
143 2.16
180 2.42
270 2.97
360 3.43
540 4.25
720 4.95
750 5.00
1000 5.89
1500 7.33
2000 8.57
2250 9.14
3000 10.67
Max. Operating Voltage - UL: 300 V RMS
Other Electrical Characteristic 1: Impedance tested in accordance with ASTM D-4566
paragraph 43.2, option 2 using a 75 Ohm fixed bridge and termination.
Other Electrical Characteristic 2: Return Loss tested in accordance with ASTM D-4566
paragraph 45.3, using a 75 Ohm fixed bridge and termination.
NOTE:Price per meter |