Content | RS232 Digital Sound Level Meter 8921/8922
- Deluxe super large LCD display w/ affordable price
- Meet IEC60651, type2 class standard
- Unique background noise absorber
- Features w/digital display and analog bar graph
- Professional and rigid design
- Auto / manual ranging ,6 measurement ranges in 10 steps
- Max hold
- Record max / min
- Fast / Slow response mode is selectable
- A /C weighting is selectable
- Easy to calibrate by standard calibrator
- AC/DC analog output
- Tripod mountable
- Backlight function to use in dark area (8922only)
SPECIFICATIONS
Measure range A weight: 30dB~130dB
C weight: 35dB~130dB
Digital display (6 ranges) 30~80, 40~90, 50~100, 60~110, 70-120, 80-130dB
Digital display resolution 0.1dB
Digital updating time 160mS
Quasi-analog bar (6 ranges) 30~80, 40~90, 50~100, 60~110, 70-120, 80-130dB
Quasi-analog bar resolution 1dB
Bar updating time 40mS
Accuracy at 94dB, 1KHz +/-1.5dB
Analog output Microphone AC 0.707Vrms(at full scale); DC 10mV/dB
Dia.6mm electric condenser microphone
Frequency range 31.5Hz~8KHz
Battery life time 30 hours typical
Windscreen LCD YES
size (mm) 42(H)x62(W)
Operating temp. 0~50oC
Operating RH% Humidity
Storage temp. -20~50oC
Storage RH% Humidity
Dimension(mm) Weight 254x77x37
Battery 9V battery x 1pc or 9VDC adaptor
Standard Package Meter/Battery/Manual/carry case
Optional Accessory Computer connection software kit
- DIGITAL DISPLAY WITH ANALOG GRAPH!
- BACKGROUND NOISE ABSORBER !
- BACKLIGHT FOR DARK AREA OPERATION!
- MAX / MIN RECORD, MAX HOLD !
- RS232 INTERFACE !
- MEETS IEC 651, TYPE 2 CLASS !
| Tests XLR, 1/4 in., 1/8 in., TT, RCA and MIDI connectors.
The intelligent, CPU-controlled CT100 accepts virtually any connector type:
XLR, mono and TRS phone (1/4 in., 1/8 in., TT), RCA and MIDI. It shows
which input pin is connected to which output pin. Separate LEDs indicate
proper shield connection and phantom power presence. The CT100 also
offers an installed cable test mode and a continuity check plus a test tone
generator.
Features
3 modes: cable test mode, installed cable test mode, and test tone mode
Accepts XLR, mono and stereo TRS phone (1/4 in., 1/8 in., TT),
RCA and MIDI Connectors
Continuity check
Intermittent detect
Phantom power detect
Grounded shield detect
Test tone generation (1 kHz and 440 Hz)
Battery operation (requires 2 AA alkaline batteries) | With the PAN05, two microphone signals can be mixed down to one. Since decoupling occurs via the balanced resistor network, the PAN05 also lets phantom power "pass through“, useful for condenser microphones. However, due to the difference in sound and signal level, mixing dynamic and condenser mics should be avoided. Best results will be achieved using two identical mics.
SPECIFICATIONS:
- Input: 2 x XLR/f balanced
- Nominal impedance: 200 Ω
- Output 1 x XLR/m balanced
- Load impedance >200 Ω
- Symmetrically decoupled through resistors
- Total ohmic value: 200 ohms
- Typical attenuation: 6 dB
- Housing: metal casing 110 x 73 x 42 mm
|
Minilyzer ML1 is the state-of-the-art analog audio meter that fits
into the palm of your hand.
It provides you with a comprehensive set of functions essential
for the analysis of professional audio systems.The powerful Minilyzer
continuously measures the audio signal and displays the desired
results with all complementary information on an illuminated hi-res
graphical LC-Display.
The Minilyzer and the MiniSPL form a comprehensive integrating
sound level meter.
MiniLINK, the USB interface for the Minilyzer allows documentation
and data acquisition of all ML1 functions in conjunction with the easy
to use MiniLINK PC application. MiniLINK supports online data logging
up to several days.
Product-details
Measurement functions:
Level RMS, Relative
Sound Pressure Level
Distortion Analyzer (THD+N), k2 - k5 harmonics
VU & PPM Meter
Speaker Polarity Test(for all speaker types)
Signal Balance Error
Frequency-/Time-Sweep Recording
1/3rd Octave Spectrum RMS & SPL
Scope
| GP-300 Infrared Thermometer is specially designed to take the body temperature of a person regardless of room temperature.
Features:
- Precise non-contact measurements
- User selectable ºC or ºF
- Selectable Body and Surface temp
- Set Alarm value for fever warning
- Access to multiple memory values up to 32 records
- Trigger lock
- Automatic Data Hold & Auto power off
- Automatic selection range and Display Resolution 0.1ºC (0.1ºF)
- Backlight LCD display
- Size 149 x 95 x 44 mm
- Weight 172g
- CE certified
Specifications
|
The PMBL is a 2 channel passive line level merge box. Each channel has 2 balanced XLR/f inputs. The input signal is merged via a resistor network to a XLR/m output.The top side input is transformer isolated. Possible applications might be the routing of two mixing desks to one power amp or mixing a stereo signal down to mono. Our transformer technology allows for an unbalanced top side input to be sent out balanced.
Specifications:
- Each Channel: Input 1 transformer balanced XLR/f. Symmetrically decoupled through resistors
- Total ohmic value: 2 K Maximum level for THD
|
Reviews