RS232 Digital Sound Level Meter 8921/8922 Deluxe super large LCD display w/ affordable price Meet IEC60651, type2 class standard Unique background noise absorber Features w/digital display and analog bar graph Professional and rigid design Auto / manual ranging ,6 measurement ranges in 10 steps Max hold Record max / min Fast / Slow response mode […]
Deluxe super large LCD display w/ affordable price
Meet IEC60651, type2 class standard
Unique background noise absorber
Features w/digital display and analog bar graph
Professional and rigid design
Auto / manual ranging ,6 measurement ranges in 10 steps
Max hold
Record max / min
Fast / Slow response mode is selectable
A /C weighting is selectable
Easy to calibrate by standard calibrator
AC/DC analog output
Tripod mountable
Backlight function to use in dark area (8922only)
SPECIFICATIONS
Measure range A weight: 30dB~130dB
C weight: 35dB~130dB
Digital display (6 ranges) 30~80, 40~90, 50~100, 60~110, 70-120, 80-130dB
Digital display resolution 0.1dB
Digital updating time 160mS
Quasi-analog bar (6 ranges) 30~80, 40~90, 50~100, 60~110, 70-120, 80-130dB
Quasi-analog bar resolution 1dB
Bar updating time 40mS
Accuracy at 94dB, 1KHz +/-1.5dB
Analog output Microphone AC 0.707Vrms(at full scale); DC 10mV/dB
Dia.6mm electric condenser microphone
Frequency range 31.5Hz~8KHz
Battery life time 30 hours typical
Windscreen LCD YES
size (mm) 42(H)x62(W)
Operating temp. 0~50oC
Operating RH% Humidity
Storage temp. -20~50oC
Storage RH% Humidity
Dimension(mm) Weight 254x77x37
Battery 9V battery x 1pc or 9VDC adaptor
Standard Package Meter/Battery/Manual/carry case
Optional Accessory Computer connection software kit
DIGITAL DISPLAY WITH ANALOG GRAPH!
BACKGROUND NOISE ABSORBER !
BACKLIGHT FOR DARK AREA OPERATION!
MAX / MIN RECORD, MAX HOLD !
RS232 INTERFACE !
MEETS IEC 651, TYPE 2 CLASS !
User's ManualA stage is only as good as its cables — and the AHMCT 8 sets the record straight.
The AHMCT 8 tests the most critical cables on the stage itself and flags up whether they are functioning or not, both visibly via LEDs and audibly via a buzzer. This makes it the perfect tool for engineers — both in the workshop and on stage.
The Pro AHMCT is operated simply, intuitively and safely via a single rotary switch on the device. The sturdy metal housing withstands even tough on-stage demands.
The standard kit comes with two test probes for carrying out fast and simple continuity tests on various cables or installations.
Solid metal housing
Powered by a 9-V block battery
Tests Speakon, XLR, jack/TRS, cinch and midi/DIN cables
Additional continuity tester with measuring probes
Optical display and buzzer
Product type Test Equipment
Connectors 6.3 mm Jack , Banana plug , DIN 5-pin , RCA , Speakon, 4-pin , XLR
Controls down , Power On/Off , up , volume
Indicators battery status , LED chain
Operating voltage 9 V block
Acoustic continuity test yes
Test cable yes
Cabinet material sheet steel
Cabinet surface powder coated
Width 105 mm
Depth 145 mm
Weight 0,64 kg
Digilyzer? DL1
Digital audio analyzer / audio meter with integrated speaker, audio lens and a
comprehensive event logger. Digital audio becomes simple by using the Digilyzer DL1.
The digital audio meter Digilyzer DL1 provides a comprehensive set of analysis
functions for digital, audio and video related audio signals.
It handles virtually all digital audio formats including ADAT and sampling frequencies
up to 96 kHz. The simple and intuitive operation allows the user to monitor, analyze
and troubleshoot any digital signals.
Debugging of digital audio signals becames easy with the assistance of the Digilyzer:
Features like the integrity check, the integrated speaker with audio lens function, the
logging functions, the ?over all? view of all important parameters and many more functions
to allow you to understand whats going on and finding faults easier than ever.
The Digilyzer is a handheld, battery powered device with optional mains power supply and
optional USB interface called MiniLINK.
MiniLINK, the USB interface for the Digilyzer allows documentation and data acquisition of
all DL1 functions in conjunction with the easy to use MiniLINK PC application. MiniLINK
supports online data logging up to several days. Read more about MiniLINK.
Product-details
? AES3, S/PDIF, TOS-Link
? ADAT Interface
? Sampling Frequency 32-96 kHz
? Digital Audio Analysis
? Carrier Status Analysis
? Carrier Signal Measurement
? Dual Domain Monitor Speaker
? Comprehensive Event Logger
This is an on-the-road tool you certainly can't miss in your gearbox! A nifty, handy cabletester, which allows you to check up to six (welding) connections and gives you a visual readout by 2 rows of 6 LED's. The checking itself is done manually per connected pin. A LED will light up to indicate what pin is connected correctly on which side. A short-circuit check with a red LED and audio-warningsignal is also included. On the left and right side you'll find inputs for 6,3 symm. jack, BNC, RCA, 5p. DIN, 5p. XLR, 3p. XLR and Neutrik® Speakon®.
We all know how frustrating and time consuming it can be when your audio cables fail. With the dbx CT2 cable testing unit you can now evaluate a large variety of your cables with ease. The CT2 offers many common connectors such as Speaker Twist, XLR, Phono, BNC, DIN, TRS, TS, DMX, & Banana. The CT2 allows for testing cables even with different connectors at each end. For example, it is simple to test a TRS to XLR cable. With well illuminated LED indicators and a simple rotary dial, users can quickly establish whether a cable is wired and functioning correctly, or if it is dead and in need of repair.
Features
6-position rotary selector with individual LEDʼs for up to five pins plus internal battery life check
ʽBananaʼ connector continuity tester with beeper and LED indicator
Super-rugged construction for durability and longer life
(2) Speaker Twist connectors for testing of 4 pin->to pin connections
(2) XLR connectors (1 x Male, 1 x Female) for testing of 3 pin->to pin connections
(2) RCA Phono connectors for testing of 2 pin->to pin connections
(2) BNC connectors for testing of 2 pin->to pin connections
(2) MIDI (5-pin DIN) connectors for testing of 5 pin->to pin connections
(2) DMX (5-pin) connectors for testing of 5 pin->to pin connections
(2) 1/4” TRS connectors for testing of 3 pin->to pin connections
(2) Banana connectors for testing of 1 pin->to pin connections
Specifications
Power Requirements
9V battery (Battery not included)
Dimensions
3.5” (8.9cm) (W) x 5.5” (14cm) (L) x 1.5” (3.7cm) (H)
ACOUSTILYZER
The Acoustilyzer AL1 functionality complements and expands the ML1
Minilyzer with a new and comprehensive set of acoustical measurement
functions.
The optimized combination of electrical and acoustical features creates
the perfect all in one tool for sound/systems contractors, installers and
multi-media specialists. The Acoustilyzer AL1 is available as a palm-sized
portable acoustical analyzer or as firmware for Minilyzer owners with optional
available STI-PA measurement functionality.
Required Accessories:
The AL1 requires a measurement microphone for acquiring acoustical signals.
NTI offers the following microphones:
- MiniSPL, class 2 acc. IEC 61672
- M2010, class 1 frequency response (ext. phantom power supply required)
Product Details
Sound Pressure Level: Leq, short-time Leq , LE, Lmin, Lmax,
Real Time Analyzer: 1/1 or 1/3 octave band resolution SPL/LEQ display per
band, max - min display
Zoom FFT: Actual level and Leq, full band up to 0.7Hz resolution
Reverberation Time: RT60 with 1/1 octave band resolution, confidence indicator,
according to ISO3382
Delay Time: Propagation delay between electrical and acoustical signal (built in mic),
resolution: 0.1ms
STI-PA (optional): Single value STI or CIS test result, modulation indices display,
individual band level results, error indicator, amplitude weighting acc. IEC 60268-16
release 2003
Electrical: Level RMS, THD+N, Polarity
Measurement microphone: Required for acquiring acoustical signals, NTI offers MiniSPL
or M2010 measurement microphones
With the PAN05, two microphone signals can be mixed down to one. Since decoupling occurs via the balanced resistor network, the PAN05 also lets phantom power "pass through“, useful for condenser microphones. However, due to the difference in sound and signal level, mixing dynamic and condenser mics should be avoided. Best results will be achieved using two identical mics.
SPECIFICATIONS:
This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Cookie settingsACCEPT
Privacy & Cookies Policy
Πολιτική χρήσης
Αυτός ο ιστότοπος χρησιμοποιεί cookies για να βελτιώσει την εμπειρία σας ενώ περιηγείστε στον ιστότοπο. Από αυτά τα cookies, κάποια cookie κατηγοριοποιούνται ως απαραίτητα να αποθηκεύονται στο πρόγραμμα περιήγησης σας, καθώς είναι απαραίτητα για τη λειτουργία βασικών λειτουργιών του ιστότοπου. Χρησιμοποιούμε επίσης cookies τρίτων που μας βοηθούν να αναλύσουμε και να κατανοήσουμε πώς χρησιμοποιείτε αυτόν τον ιστότοπο. Αυτά τα cookies θα αποθηκευτούν στο πρόγραμμα περιήγησης σας μόνο με τη συγκατάθεσή σας. Έχετε επίσης την επιλογή να εξαιρεθείτε από αυτά τα cookies. Ωστόσο, η εξαίρεση από ορισμένα από αυτά τα cookie μπορεί να επηρεάσει την εμπειρία περιήγησης σας.
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.
Reviews
There are no reviews yet.