Price | €151.28 incl. GR VAT | €502.25 €408.00 incl. GR VAT | €1,328.00 €1,169.00 incl. GR VAT | €5,442.00 €4,789.00 incl. GR VAT | €3,363.00 €2,959.00 incl. GR VAT | €130.99 €110.00 incl. GR VAT |
Content |
Capsule: Hand-crafted, 1" diaphragm, gold-sputtered
Frequency Response: 20Hz-20kHz
Sensitivity: -32 dBV/Pa (25.1mV/Pa)
Polar Pattern: Cardioid
Impedance: ≤ 200 Ohms
Equivalent Noise Level: 16dB (A-weighted)
Max SPL for 0.5% THD @1kHz: 125dB
Power Requirement: Phantom power 48V±4V
Connector: 3-pin XLR | AKG C214 – large 1” diaphragm microphone with cardioid polar pattern, frequency response: 20Hz-20kHz, 20dB pad, requires phantom power (12-52V), XLR connector. Includes clip, case and windshield. Dimensions: 160 x 55mm. Weight: 280g, optional microphone holder SA61
The C214 professional large-diaphragm condenser microphone has been designed as a cost-effective alternative to the high-end C414 family. Like the C414, the C214 offers a supreme one-inch capsule on an integrated suspension to reduce mechanical noise. A switchable 20dB attenuation pad allows recording of loud sources of up to 156dB SPL. A switchable bass-cut filter allows close-up recording with almost no proximity effect.
The C214 captures sound by combining one capsule of the legendary C414 dual-capsule system and the patented AKG Back-Plate Technology, resulting in an outstanding performance close to the famous C414 XLII.
Sonic character of the C414 XLII
for beautifully detailed recording of lead vocals and solo instruments
Outstanding dynamic range and ultralow noise
for close-up recording of high-output sources of up to 156dB SPL
Switchable 20dB attenuator and bass-cut filter
for close-up recording and reduction of proximity effect
Integrated suspension
to reduce mechanical noise and vibration from stage
Roadworthy design
all-metal die-cast body with shock- and scratch-resistant finish |
Large diaphragm cardioid microphone | Pressure gradient transducer with with one-diaphragm capsule | Transformerless circuitry | Extremely low noise: 7 dB-A | Includes swivel mount | Straightforward handling for homerecording and professional studios |
High-quality professional equipment for limited budgets
Acoustical operating principle | Pressure gradient transducer | Directional pattern | Cardioid | Frequency range | 20 Hz ... 20 kHz | Sensitivity at 1 kHz into 1 kohm | 23 mV/Pa | Rated impedance | 50 ohms | Rated load impedance | 1 kohms | Equivalent noise level, CCIR1) | 17.5 dB | Equivalent noise level, A-weighted1) | 7 dB-A | Signal-to-noise ratio, CCIR1) (rel. 94 dB SPL) | 76.5 dB | Signal-to-noise ratio, A-weighted1) (rel. 94 dB SPL) | 87 dB | Maximum SPL for THD 0.5%2) | 138 dB | Maximum output voltage | 13 dBu | Dynamic range of the microphone amplifier (A-weighted) | 131 dB | Supply voltage (P48, IEC 61938) | 48 V ± 4 V | Current consumption (P48, IEC 61938) | 3 mA | Matching connector | XLR3F | Weight | approx. 450 g | Diameter | 60 mm | Length | 132 mm |
|
|
Acoustical operating principle | Pressure gradient transducer | Directional pattern | Omnidirectional, wide angle cardioid, cardioid, hypercardioid, figure-8 plus one intermediate position each | Frequency range | 20 Hz ... 20 kHz | Sensitivity at 1 kHz into 1 kohm | 34/47/62 mV/Pa* | Rated impedance | 50 ohms | Rated load impedance | 1000 ohms | Equivalent SPL CCIR 468-3 | 28/25/23 dB* | Equivalent SPL DIN/IEC 651 | 16/13/11 dB-A* | S/N ratio CCIR 468-3 | 66/69/71 dB* | S/N ratio DIN/IEC 651 | 78/81/83 dB* | Typical SPL (tube characteristic) | K | Maximum output voltage | 18 dBu | Dynamic range of the microphone amplifier cardioid DIN/IEC 651 for | 101 (121) dB | Powering | Power supply N 149 | Matching connectors | Microphone DIN 8F, Power supply XLR 3F | Weight | 730 g | Diameter | 70 mm | Length | 201 mm |
* Omnidirectional / cardioid / figure-8
|
Acoustical operating principle | Pressure gradient transducer | Directional pattern | Cardioid | Frequency range | 20 Hz ... 20 kHz | Sensitivity at 1 kHz into 1 kohm | 20 mV/Pa | Rated impedance | 50 ohms | Rated load impedance | 1000 ohms | Equivalent SPL CCIR 468-3 | 24 dB | Equivalent SPL DIN/IEC 651 | 12 dB-A | S/N ratio CCIR 468-3 | 70 dB | S/N ratio DIN/IEC 651 | 82 dB | Maximum SPL | 114 dB for THD | Maximum output voltage | 8 dBu | Dyn. range of the mic. amplifier DIN/IEC 651 | 102 dB for THD | Supply voltage | Power supply N 149 A | Matching connector | Microphone: DIN 8F, Power Supply: XLR 3F | Weight | 460 g | Diameter | 57 mm | Length | 142 mm |
| Live sound
Podcasting
Home recording
Vocals
Musical instruments |
Perception 120 |
|
- General-purpose cardioid recording microphone
- Extended frequency response
- Roadworthy construction
- Switchable 20 dB preattenuation pad
- Switchable bass cut filter
- Designed and engineered by AKG in Vienna, Austria
The Perception 120 is a 2/3-inch diaphragm true condenser microphone that offers solid build quality, outstanding performance, and excellent value. The low-mass diaphragm delivers a clear sound with accurate sonic detail. A switchable 20 dB preattenuation pad and bass cut filter make the Perception 120 an excellent choice for a wide range of recording and live sound applications.
Backed by AKG\'s six decades of experience in making microphones and input from sound engineers around the world, the Perception 120 now brings AKG studio quality to musicians and project studio applications.
Type |
2/3\" Diaphragm True Condenser |
Polar pattern |
cardioid |
Frequency range |
20 to 20,000 Hz |
Sensitivity |
22 mV/Pa (-33 dBV) |
Max. SPL |
130/150 dB (0/-20 dB) for 0.5% THD |
Equivalent noise level |
22 dB-A (IEC 60268-4) |
Signal/noise ratio (A-weighted) |
72 dB |
Preattenuation pad |
0 dB, -20 dB |
Bass filter |
12 dB/octave at 300 Hz |
Impedance |
|
Recommended load impedance |
>= 1,000 ohms |
Powering |
|
Power requirement |
48 V phantom power to DIN/IEC |
Connector |
3-pin XLR |
Finish |
metallic blue |
Dimensions |
53 dia. x 165 mm (2.1 dia. x 6.5 in.) |
Net weight |
525 g (18.5 oz.) |
Shipping weight |
955 g (33.7 oz.) |
|
Reviews
There are no reviews yet.