Content |
Electro-Voice Cobalt CO9
The Co9 is a favorite among vocalists across all musical genres.
Technical Specifications
Element: Dynamic Neodymium magnet structure
Frequency Response 50 Hz to 18 kHz
Polar Pattern Cardioid
Impedance Low-Z balanced (600 Ohms) Sensitivity Open Circuit Voltage 3.2 mV/PA (-50 dBV) re 1 Pa* 1 Pa = 94 dB SPL
Microphone Connector 3-pin, XLR-type
Polarity Pin 2 positive, referenced to pin 3 with positive pressure on diaphragm
Finish Durable polyurethane paint
Materials Die cast zinc housing
Dimensions Length 6.7 in. (170 mm) Diameter 2.1 in. (53 mm) Shank .85 in. (22 mm)
Weight Net 11.8 oz. (306 grams) Shipping 29.9 oz. (819 grams)
Accessories included Stand adaptor (black) Gig bag
| The P 3 S microphone is ideal for backing vocals, guitar, wind instruments and many other applications. It has a metal case and wire mesh grill to ensure exceptional ruggedness.
Key Features:
- Rugged performance microphone designed for backing vocals and instruments
- Rugged wire mesh cap with internal windscreen
- Die-cast metal body
- Complete with stand adapter and zip bag
- On/Off switch
Specifications:
- Polar pattern Cardioid
- Frequency range 40 to 18,000 Hz
- Sensitivity 2.5mV/Pa
- Max. SPL 144 dB SPL
- Recommended load impedance >=2,000 ohms
|
WITH XLR SWITCH ON/OFF
Polar pattern | supercardioid | Frequency range | 70 Hz to 20 kHz | Sensitivity | 2.6 mV/Pa (-52 dBV) | Max. SPL | 147/156 dB SPL (for 1% / 3% THD) | Equivalent noise level | 18 dB-A | Impedance | = 2000 ohms | Connector | 3-pin XLR | Finish | matte grayish blue | Dimensions | length: 185.2 mm (7.3 in.); diameter: 51 mm (2 in.) | Net weight | 340 g (12 oz.) | Shipping weight | 655 g (1.45 lbs.) | Patent(s) | Varimotion – multiple-thickness diaphragm for dynamic transducer (Patent no. AT 403.751, US 6,185,809, EP 814.637 (DE, DK, FI, FR, GB, IT, NL), JP 3.927.651) |
|
The UNlDYNE? III Model 545SD is a dual-impedance, unidrectional, dynamic microphone. Shipped connected for low-impedance operation, it features a silent magnetic reed on/off switch.
The 545SD is a favorite for instrument pickup and recording, and can be used on lecterns for public address systems such as those used in political conventions and legislatures, convention halls, hotels, public auditoriums, stadiums, schools, and churches.
- Exceptionally uniform cardioid pattern minimizes feedback in PA applications
- Selectable dual-impedance operation
- Silent magnetic reed on/off switch with lock-on option
- Cardioid dynamic
- Frequency response: 50 to 15,000 Hz.
|
The cardioid e 935 is a fully professional vocal microphone,
developed to cut through high on-stage levels.
Features
Rugged metal body
Advanced shock-mount design
Consistent on-/off-axis response
Hum compensating coil
Made in Germany
Delivery includes a pouch and a microphone clamp
Delivery Includes
1 e 935
MZQ 800 microphone clamp
Pouch
Technical Data
Pick-up pattern Cardioid
Frequency response (microphone) 40.....18000 Hz
Sensitivity in free field, no load (1kHz)
2,8mV/Pa bei 1 kHz = -51dB (0 dB = 1V/Pa) = -71 dB (0 dB = 1V/ubar)
Nominal impedance 350 Ohm
Min. terminating impedance 1000 Ohm
Dimensions 47 x 181 mm
Weight 330 g
|
In the tradition of the SM58?, the Beta 58A dynamic microphone has become a top choice among vocalists and touring sound professionals.
The Shure Beta 58A is a high-output supercardioid dynamic vocal microphone designed for professional sound reinforcement and project studio recording. It maintains a true supercardioid pattern throughout its frequency range. This insures high gain-before-feedback, maximum isolation from other sound sources, and minimum off-axis tone coloration. The Beta 58A has a shaped frequency response that is ideal for close-up vocals. The superb performance of this microphone is not affected by rough handling because of its rugged construction, proven shock mount system, and hardened steel mesh grille. Typical applications for the Beta 58A include lead vocals, backup vocals and speech.
- Smooth, extended frequency response for outstanding sound for professional live vocal use
- Consistent supercardioid pattern provides the best gain-before-feedback among dynamic microphones
- Pneumatic shock mount reduces handling noise
- Frequency response: 50 to 16,000 Hz
-
Frequency response tailored for vocals, with brightened midrange and bass rolloff to control proximity effect
-
Uniform supercardioid pattern for high gain before feedback and superior rejection of off–axis sound
-
Neodymium magnet for high signal–to–noise output
-
Hardened steel mesh grille that resists wear and abuse
-
Advanced pneumatic shock mount system that minimizes transmission of mechanical noise and vibration
-
Minimally effected by varying load impedance
-
Legendary Shure quality and reliability
Transducer |
(Moving Coil, with Neodymium Magnet) Dynamic |
Polar Pattern |
Supercardioid |
Frequency Response |
50 Hz - 16 kHz |
Maximum Input Sound Level |
not specified by manufacturer |
Power Requirements |
None Dynamic, Requires No Phantom or Battery Power |
Output Impedance |
150 Ohms (290 Ohms Actual) |
Output Connectors |
XLR-3 Type |
Dimensions |
6.375 x 2" (162 x 51mm) LxDiameter |
Weight |
9.92 oz. (278 g) |
|
Reviews