AKG CGN 99H/L 58cm Hypercardioid Gooseneck Microphone

No longer available!

129.00 incl. GR VAT

Out of stock

CompareAdd to wishlist Submit Better Price
Availability: No longer available! No longer available! SKU: CGN 99H/L Category:
Hypercardioid polar pattern 50 cm ( 20 in.) long 95° pickup angle For acoustically difficult environments Connects easily via XLR connector The hypercardioid polar pattern with its narrow 95° pickup angle is suited best for situations where noise typically occurs from all sides (particularly in worship centers), where people talk into the microphone from a […]

 

Read more

  • Hypercardioid polar pattern
  • 50 cm ( 20 in.) long
  • 95° pickup angle
  • For acoustically difficult environments
  • Connects easily via XLR connector

The hypercardioid polar pattern with its narrow 95° pickup angle is suited best for situations where noise typically occurs from all sides (particularly in worship centers), where people talk into the microphone from a greater distance, or where several talkers are grouped side by side. Two different lengths are available. The .exible joint ensures optimum alignment of the gooseneck to any talker position. Several options are available for installation, i.e., stand, tabletop installation, and lockable.

Choosing polar patterns

Selecting the correct polar pattern for installed sound is difficult since it depends on a variety of factors. Of course the acoustics of the room play a key role. For highly reverberant rooms such as worship centers, a hypercardioid polar pattern will be the best choice to avoid high levels of unwanted noise. Correct placement of the loudspeakers is also essential. If the speakers project right at the capsule, a hypercardioid will be your best bet. The most difficult task, however, is trying to judge how the talkers will behave. For talkers who are inexperienced or move around a lot, be sure to choose a cardioid polar pattern for reliable pickup; talkers at a greater distance from the mic will be served best by a hypercardioid.

The microphone shall be a hypercardioid gooseneck microphone. Its pickup angle shall be 95 degrees; frequency range 50 Hz to 19 kHz; sensitivity 12 mV/Pa; max. SPL 125 dB; electrical impedance

 

Polar pattern Hypercardioid
Frequency range 50 to 19,000 Hz
Sensitivity 12 mV/PA = -38 dBV re 1 V/Pa
Max. SPL 125 dB (for 1% THD)
Equivalent noise level
Signal/noise ratio (A-weighted) >73 dB
Impedance =2,000 ohms
Supply voltage English: 9 to 52 V phantom power to IEC 61938 (DPA adapter integrated)
Powering
Connector 3-pin male XLR
Finish matte black
Dimensions CGN 99 H/S: 13.5 x 380 mm (0.5 x 15 in.);
CGN 99 H/L: 13.5 x 580 mm (0.5 x 23 in.)
Net weight

CGN 99 H/S: 480 g (17 oz.);
CGN 99 H/L: 500 g (17.7 oz.)

 

 Optional accessories

  B 18
Battery power supply
 
  H 500
Shock mount
 
  H 600
Shock mount
 
  PS 3 F-Lock
Installation hardware
 
  SA 60
Stand adapter
 
  ST 1
Mini-tripod
 
  ST 45
Table stand
 

 

Weight 0.48 kg

Reviews

There are no reviews yet.

Be the first to review “AKG CGN 99H/L 58cm Hypercardioid Gooseneck Microphone”

Your email address will not be published. Required fields are marked *

Quick Comparison

AKG CGN 99H/L 58cm Hypercardioid Gooseneck Microphone removeAUDAC AUCMX21035 Revolving Gooseneck Microphone 40cm removeSENNHEISER E-908D Condenser Microphone Gooseneck removeShure MX418D-C Gooseneck Cardioid Condenser Microphone removeAKG CGN 99H/S 38cm Hypercardioid Gooseneck Microphone removeSHURE MX-412S-C 12 remove
NameAKG CGN 99H/L 58cm Hypercardioid Gooseneck Microphone removeAUDAC AUCMX21035 Revolving Gooseneck Microphone 40cm removeSENNHEISER E-908D Condenser Microphone Gooseneck removeShure MX418D-C Gooseneck Cardioid Condenser Microphone removeAKG CGN 99H/S 38cm Hypercardioid Gooseneck Microphone removeSHURE MX-412S-C 12 remove
ImageAKG CGN 99HS 38cm Hypercardioid Gooseneck Microphone-artsound
SKUCGN 99H/LAUCMX21035H10SE00100MX418D-CCGN 99H/SMX214SC
Rating
Price 129.00 incl. GR VAT 105.40 incl. GR VAT 279.00 incl. GR VAT 339.00 incl. GR VAT149.00 incl. GR VAT 268.00 incl. GR VAT
Stock

Out of stock

In stock

Available on backorder

In stock

Only 2 left in stock (can be backordered)

In stock

AvailabilityOut of stockIn stockAvailable on backorderIn stockOnly 2 left in stock (can be backordered)In stock
Add to cart

Read more

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description
Content
  • Hypercardioid polar pattern
  • 50 cm ( 20 in.) long
  • 95° pickup angle
  • For acoustically difficult environments
  • Connects easily via XLR connector

The hypercardioid polar pattern with its narrow 95° pickup angle is suited best for situations where noise typically occurs from all sides (particularly in worship centers), where people talk into the microphone from a greater distance, or where several talkers are grouped side by side. Two different lengths are available. The .exible joint ensures optimum alignment of the gooseneck to any talker position. Several options are available for installation, i.e., stand, tabletop installation, and lockable.

Choosing polar patterns

Selecting the correct polar pattern for installed sound is difficult since it depends on a variety of factors. Of course the acoustics of the room play a key role. For highly reverberant rooms such as worship centers, a hypercardioid polar pattern will be the best choice to avoid high levels of unwanted noise. Correct placement of the loudspeakers is also essential. If the speakers project right at the capsule, a hypercardioid will be your best bet. The most difficult task, however, is trying to judge how the talkers will behave. For talkers who are inexperienced or move around a lot, be sure to choose a cardioid polar pattern for reliable pickup; talkers at a greater distance from the mic will be served best by a hypercardioid.

The microphone shall be a hypercardioid gooseneck microphone. Its pickup angle shall be 95 degrees; frequency range 50 Hz to 19 kHz; sensitivity 12 mV/Pa; max. SPL 125 dB; electrical impedance

 

Polar pattern Hypercardioid
Frequency range 50 to 19,000 Hz
Sensitivity 12 mV/PA = -38 dBV re 1 V/Pa
Max. SPL 125 dB (for 1% THD)
Equivalent noise level
Signal/noise ratio (A-weighted) >73 dB
Impedance =2,000 ohms
Supply voltage English: 9 to 52 V phantom power to IEC 61938 (DPA adapter integrated)
Powering
Connector 3-pin male XLR
Finish matte black
Dimensions CGN 99 H/S: 13.5 x 380 mm (0.5 x 15 in.);
CGN 99 H/L: 13.5 x 580 mm (0.5 x 23 in.)
Net weight

CGN 99 H/S: 480 g (17 oz.);
CGN 99 H/L: 500 g (17.7 oz.)

 

 Optional accessories

  B 18
Battery power supply
 

  H 500
Shock mount
 

  H 600
Shock mount
 

  PS 3 F-Lock
Installation hardware
 

  SA 60
Stand adapter
 

  ST 1
Mini-tripod
 

  ST 45
Table stand
 

 

The CMX200 is a 360° revolving gooseneck microphone, designed to be used for conferences, sound reinforcements, translations and studio applications. It has a high sensitive condenser element with a unidirectional cardioid polar pattern which ensures an excellent sound quality and reduces the feedback to a strict minimum, even when exposed to vigorous, hard sound.

Thanks to its flat frequency characteristic, the CMX200 ensures a permanent high-fidelity sound, true to the userʼs voice and intonation. The dark grey color and slimline design permit a discreet blending with every possible interior or background.

  • Model Name / Type: CMX20035 / Gooseneck Microphone
  • Polar Pattern: Cardioid
  • Impedance: 250 ohms
  • Frequency Response: 50 Hz - 16 kHz
  • Sensitivity: - 45 +/- 3 dB
  • Dynamic Range: 113 dB
  • Phantom Power 15 - 52 V DC
  • Diameter: 19 mm
  • Length: 400 mm

The evolution e 908 instrument microphone is available in four variants:
as e 908 D for drums and percussion
as e 908 B for wind instruments, congas, and drums with free-floating suspension system
as e 908 B ew for the wireless miking of saxophones using an evolution wireless instrument transmitter
as e 908 T ew for the wireless miking of trumpets using an evolution wireless instrument transmitter

  • Pick-up pattern : cardioid
  • Frequency response : 40 ... 20 000 Hz
  • Sensitivity in free field, no load : (1kHz) 4 mV/Pa, 0,56mV/Pa (e 908T-ew)
  • Equivalent noise level : e908B-ew = 30 dB(A); e908B & e908D = 35 dB(A), e908T-ew = 39 dB (A)
  • Max. Sound pressure level (aktiv) : 147 dB
  • Nominal impedance : 100 Ohm (e908B & e908D)
  • Min. terminating impedance : 2000 Ohm (e908B & e908D)
  • Phantom powering : 12 - 48 V / 3 mA (e908B & e908D)
  • Weight : ca. 140 g
  • Dimensions : Ø 47 x 193 mm

Shure MX418D-C Gooseneck Cardioid Condenser Microphone

Microflex? Gooseneck microphones bring a whole new meaning to the word flexible
with their fully adjustable gooseneck. Designed for easy replacement and available in
cardioid, supercardioid and omnidirectional polar patterns, the interchangeable cartridges
offer wide frequency response and accurate sound reproduction for a wide variety of applications
such as houses of worship, courtrooms and conference centers. Plus, the condenser cartridges
fit every model in the Microflex product line for enhanced convenience and consistent sound.

Microflex Gooseneck microphones are available in four models with a variety of heights and mounting
styles to choose from. One model includes a silent mute switch with LED indicator, a Shure Microflex
exclusive. And every Microflex Gooseneck features high sensitivity and balanced, transformerless output
for maximum resistance to electromagnetic hum and RF interference, even over long cable runs.

Desktop Base with 10 foot Cable, Logic Functions, Programmable Switch and LED Indicator, Snap-Fit Foam Windscreen

Features:

Wide dynamic range and frequency response for accurate sound reproduction across the audio spectrum
Interchangeable cartridges provide the right polar pattern for every application
Balanced, transformerless output for increased immunity to noise over long cable runs
Shock mount provides over 20 dB isolation from surface vibration noise
Locking flange mount for permanently securing microphone to lecterns, pulpits, or conference tables
Snap-fit foam windscreen
Programmable on/off switch and LED on/off indicator (M412D/MX418D)
New brighter LED improves visibility under strong ambient lighting M412D/MX418D)
Logic input and output terminals for remote control or use with automatic microphone mixers M412D/MX418D)
Supplied shock mount for more than 20 dB isolation from surface transmitted noise (MX412SW/MX418SE)
Supplied threaded flange mount for permanently securing the microphone to a lectern, pulpit, or conference table (MX412SW/MX418SE)

Microphone Specifications:
 
Frequency Response
50 to 17,000 Hz
Output Impedance
180 ohms actual (EIA rated at 150 ohms)
Sensitivity (At 1,000 Hz, open circuit voltage*)
Cardioid: -35.0 dBV/Pa (17.8 mV)
Supercardioid: -33.5 dBV/Pa (21.1 mV)
Omnidirectional: -27.5 dBV/Pa (42.2 mV)
All values -12 dB at 0 gain; *1 Pascal = 94 dB SPL
Maximum SPL (1 kHz at 1% THD, 1 k ohm load)
Cardioid: 124.2 dB
Supercardioid: 122.7 dB
Omnidirectional: 116.7 dB
All values +6 dB at 0 gain
Equivalent Output Noise (A-weighted)
Cardioid: 28.0 dB SPL
Supercardioid: 26.5 dB SPL
Omnidirectional: 20.5 dB SPL
Signal to Noise Ratio (referenced at 94 dB SPL)
Cardioid: 66.0 dB
Supercardioid: 67.5 dB
Omnidirectional: 73.5 dB
Dynamic Range at 1 k ohm load
96.2 dB
100 dB at 0 gain
Common Mode Rejection
45.0 dB minimum
Preamplifier Output Clipping Level (1% THD)
-6.0 dBV (0.5 V)
-12 dBV at 0 gain
Polarity
Positive sound pressure on diaphragm produces positive voltage on pin 2 relative to pin 3 of output connector.
Power Requirements
11 to 52 Vdc phantom, 2.0 mA
Environmental Requirements
Operating Temperature Range: -18 to 57 degrees C (0 to 135 degrees F)
Relative Humidity: 0 to 95%

  • Hypercardioid polar pattern
  • 38 cm  long
  • 95° pickup angle
  • For acoustically difficult environments
  • Connects easily via XLR connector
The hypercardioid polar pattern with its narrow 95° pickup angle is suited best for situations where noise typically occurs from all sides (particularly in worship centers), where people talk into the microphone from a greater distance, or where several talkers are grouped side by side. Two different lengths are available. The .exible joint ensures optimum alignment of the gooseneck to any talker position. Several options are available for installation, i.e., stand, tabletop installation, and lockable. Choosing polar patterns Selecting the correct polar pattern for installed sound is difficult since it depends on a variety of factors. Of course the acoustics of the room play a key role. For highly reverberant rooms such as worship centers, a hypercardioid polar pattern will be the best choice to avoid high levels of unwanted noise. Correct placement of the loudspeakers is also essential. If the speakers project right at the capsule, a hypercardioid will be your best bet. The most difficult task, however, is trying to judge how the talkers will behave. For talkers who are inexperienced or move around a lot, be sure to choose a cardioid polar pattern for reliable pickup; talkers at a greater distance from the mic will be served best by a hypercardioid. The microphone shall be a hypercardioid gooseneck microphone. Its pickup angle shall be 95 degrees; frequency range 50 Hz to 19 kHz; sensitivity 12 mV/Pa; max. SPL 125 dB; electrical impedance
Polar pattern Hypercardioid
Frequency range 50 to 19,000 Hz
Sensitivity 12 mV/PA = -38 dBV re 1 V/Pa
Max. SPL 125 dB (for 1% THD)
Equivalent noise level
Signal/noise ratio (A-weighted) >73 dB
Impedance =2,000 ohms
Supply voltage English: 9 to 52 V phantom power to IEC 61938 (DPA adapter integrated)
Powering
Connector 3-pin male XLR
Finish matte black
Dimensions CGN 99 H/S: 13.5 x 380 mm (0.5 x 15 in.); CGN 99 H/L: 13.5 x 580 mm (0.5 x 23 in.)
Net weight CGN 99 H/S: 480 g (17 oz.); CGN 99 H/L: 500 g (17.7 oz.)

 

2-inch (30 cm) Gooseneck Condenser Microphone, Cardioid, Attached XLR Preamp, Shock Mount, Flange Mount, Snap-Fit Foam Windscreen, Mute Switch, LED Indicator.

The Microflex Gooseneck microphones bring a whole new meaning to the word flexible. Beyond their fully adjustable goosenecks lies a new level of flexibility the new Microflex interchangeable condenser microphone cartridge. Designed for easy replacement and available in cardioid, supercardioid and omnidirectional polar patterns, the interchangeable cartridges offer wide frequency response and accurate sound reproduction for a broad variety of applications, such as houses of worship, courtrooms and conference centers. Plus, the condenser cartridges fit every model in the new Microflex product line for enhanced convenience and consistent sound.

Features

  • Wide dynamic range and frequency response for accurate sound reproduction across the audio spectrum
  • Interchangeable cartridges provide the right polar pattern for every application
  • Balanced, transformerless output for increased immunity to noise over long cable runs
  • Shock mount that provides over 20 dB isolation from surface vibration noise
  • Locking flange mount for permanently securing microphone to lecterns, pulpits, or conference tables
  • Snap-fit foam windscreen

Specifications

  • Frequency Response: 50Hz to 17kHz
  • Polar Pattern: Cardioid
  • Output Impedance: rated at 150 ohms (180 ohms actual)
  • Maximum SPL: 124.2 dB
  • Signal to Noise Ratio: 66.0 dB
  • Dynamic Range: 96.2 dB
  • Power Requirements: 11 to 52 Vdc phantom, 2.0 mA
Weight0.48 kg0.34 kg0.14 kg0.50 kg0.48 kg0.40 kg
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Weight 0.48 kg
Weight 0.34 kg
Weight 0.14 kg
Weight 0.50 kg
Weight 0.48 kg
Weight 0.40 kg