Content |
- PA microphone with rugged, all-metal body
- Frequency response optimized for intelligibility
- Long useful life even in tough day-to-day usage
- Frequency response tailored to speech use
Rugged, affordable dynamic cardioid gooseneck microphone for general public address and communications use. The DGN 99 provides a frequency response tailored to speech use for optimum intelligibility as well as good offaxis rejection for high gain before feedback and suppression of unwanted ambient noise. The all-metal body ensures a long useful life for the microphone even in tough day-to-day use.
The DGN 99 E features a built-in XLR connector for quick connection, while the DGN 99 has been designed for permanent (single-hole or screw-on) installation and comes with a 6-ft. 4-in. (2-m) fixed, unterminated cable.
Ticket window, bank counter
Reception desk, restaurant
Houses of worship
|
- Cardioid instrument microphone with miniature mounting bracket
- High mechanical-noise attenuation
- Including wireless direct adapter for easy use with AKG pocket transmitters
- Detachable microphone cable
- Ideal for miking up accordions and guitar, piano, keyboard, or organ amplifiers
Polar pattern | cardiod | Frequency range | 60 Hz to 20 kHz | Sensitivity | 5 mV/Pa (-46 dBV) | Max. SPL | 130/132 dB SPL (bei k = 1 %/3 %) | Equivalent noise level | 31 dB(A) | Signal/noise ratio (A-weighted) | 63 dB | Impedance | = 2000 ohms | Current consumption | |
|
- Hypercardioid polar pattern
- 38 cm long
- 95° pickup angle
- For acoustically difficult environments
- Connects easily via XLR connector
The hypercardioid polar pattern with its narrow 95° pickup angle is suited best for situations where noise typically occurs from all sides (particularly in worship centers), where people talk into the microphone from a greater distance, or where several talkers are grouped side by side. Two different lengths are available. The .exible joint ensures optimum alignment of the gooseneck to any talker position. Several options are available for installation, i.e., stand, tabletop installation, and lockable.
Choosing polar patterns
Selecting the correct polar pattern for installed sound is difficult since it depends on a variety of factors. Of course the acoustics of the room play a key role. For highly reverberant rooms such as worship centers, a hypercardioid polar pattern will be the best choice to avoid high levels of unwanted noise. Correct placement of the loudspeakers is also essential. If the speakers project right at the capsule, a hypercardioid will be your best bet. The most difficult task, however, is trying to judge how the talkers will behave. For talkers who are inexperienced or move around a lot, be sure to choose a cardioid polar pattern for reliable pickup; talkers at a greater distance from the mic will be served best by a hypercardioid.
The microphone shall be a hypercardioid gooseneck microphone. Its pickup angle shall be 95 degrees; frequency range 50 Hz to 19 kHz; sensitivity 12 mV/Pa; max. SPL 125 dB; electrical impedance
Polar pattern |
Hypercardioid |
Frequency range |
50 to 19,000 Hz |
Sensitivity |
12 mV/PA = -38 dBV re 1 V/Pa |
Max. SPL |
125 dB (for 1% THD) |
Equivalent noise level |
|
Signal/noise ratio (A-weighted) |
>73 dB |
Impedance |
=2,000 ohms |
Supply voltage |
English: 9 to 52 V phantom power to IEC 61938 (DPA adapter integrated) |
Powering |
|
Connector |
3-pin male XLR |
Finish |
matte black |
Dimensions |
CGN 99 H/S: 13.5 x 380 mm (0.5 x 15 in.);
CGN 99 H/L: 13.5 x 580 mm (0.5 x 23 in.) |
Net weight |
CGN 99 H/S: 480 g (17 oz.);
CGN 99 H/L: 500 g (17.7 oz.) |
|
- PA microphone with rugged, all-metal body
- Frequency response optimized for intelligibility
- Long useful life even in tough day-to-day usage
- Frequency response tailored to speech use
Rugged, affordable dynamic cardioid gooseneck microphone for general public address and communications use. The DGN 99 provides a frequency response tailored to speech use for optimum intelligibility as well as good offaxis rejection for high gain before feedback and suppression of unwanted ambient noise. The all-metal body ensures a long useful life for the microphone even in tough day-to-day use.
The DGN 99 E features a built-in XLR connector for quick connection, while the DGN 99 has been designed for permanent (single-hole or screw-on) installation and comes with a 6-ft. 4-in. (2-m) fixed, unterminated cable.
Ticket window, bank counter
Reception desk, restaurant
Houses of worship
| Polar pattern Cardioid
Frequency range 70 to 18,000 Hz
Max. SPL 125 dB (for 1% THD)
Equivalent noise level 73 dB
Impedance =2,000 ohms
Supply voltage 9 to 52 V phantom power to IEC 61938 (DPA adapter integrated)
Powering |
Shure MX412SE/C 12-inch (30 cm) Gooseneck Condenser Microphone, Shock Mount, Flange Mount, 10-foot (3 m) Side-Exit Cable (or Bottom-Exit), Snap-Fit Foam Windscreen, In-Line Preamp, Cardioid.
Shure Microflex MX412SE/C microphones are miniature gooseneck-mounted electret condenser microphones designed for speech and vocal pickup. Their high sensitivity and broad frequency range make them suitable for recording, as well as sound reinforcement applications.
The MX412SE/C microphone can be screwed onto a mic stand or the supplied 5/8 inch 27-threaded flange. They can be easily changed from side-exit to bottom-exit to conceal the cable. All models include an in-line preamplifier and a 3 m (10 ft) cable. Each microphone is available with interchangeable cardioid, supercardioid, or omnidirectional cartridges. |