T E C H N I C A L D A T A
NO. OF CONDUCTORS: No. x 2 x 0,22 mm2 Tinned copper
CONDUCTOR INSULATION: PE
SHIELDING BY PAIR: Aluminium polyester foil + drain wire
COLOR OF CONDUCTEUR: White / blue
COLOR OF PAIR: By number
OVERALLSHIELD: Aluminium polyester foil + drain wire
JACKET: Black PVC
PACKAGING: Per m
SUITABLE PLUG: XLR, jacks
PRICE PER METER
| BELDEN 70032 Audio multi cable 4 pairs | Adam Hall Cables 4 STAR HPA 315 Hybrid Cable power & audio 3 x 1.5 mm² & 2 x 0,22 mm². Price per meter
General
Type
Power / Signal Cable
Temperature range
-20 - 70 °C
Power
Number of internal conductors
3
Center conductor cross section
1.5 mm²
Center conductor construction
48 x 0.20 mm
Center conductor material
OFC
Conductor resistance
85 ohm/km
Audio
Number of inner conductors 2
2
Center conductor cross section 2
0.22 mm²
Center conductor construction 2
28 x 0.10 mm
Center conductor material 2
OFC
Shield
AL/PT-foil, Copper spiral coil shield
Conductor resistance 2
55 ohm/km
|
24 AWG stranded (7x32) TC conductor, polyolefin insulation, individually shielded Beldfoil? (100% coverage) numbered/color-coded PVC jackets, jackets and shields bonded to strip simultaneously, overall Beldfoil shield and 24 AWG TC drain wire. PHYSICAL CHARACTERISTICS :
CONDUCTOR : Number of Pairs: 24 Total Number of Conductors: 48 AWG: 24 Stranding: 7x32 Conductor Diameter: .024 in. Conductor Material: TC - Tinned Copper INSULATION : Insulation Material: PO - Polyolefin Nom. Insulation Wall Thickness: .008 in. Insulation Diameter: .040 in. Lay Length: 1.75 in. Twists/ft.: 6.85 Pair Color Code Chart: Red and Black INNER SHIELD : Inner Shield Material Trade Name: Beldfoil? Inner Shield Type: Tape Inner Shield Material: Aluminum Foil-Polyester Tape Inner Shield % Coverage: 100 % Inner Shield Drain Wire AWG: 24 Inner Shield Drain Wire Stranding: 7x32 Inner Shield Drain Wire Conductor Material: TC - Tinned Copper INNER JACKET : Inner Jacket Material: PVC - Polyvinyl Chloride Inner Jacket Nominal Wall Thickness: .014 in. Inner Jacket Diameter: .111 in. Inner Jacket Color Code Chart: Number Color 1 Brown 2 Red 3 Orange 4 Yellow 5 Green 6 Blue 7 Purple 8 Gray 9 White 10 Black 11 Tan 12 Pink 13 Gray/Brown Number Color 14 Gray/Red 15 Gray/Orange 16 Gray/Yellow 17 Gray/Green 18 Gray/Blue 19 Gray/Purple 20 Gray/Gray 21 Gray/White 22 Gray/Black 23 Gray/Tan 24 Gray/Pink OUTER SHIELD : Outer Shield Material Trade Name: Beldfoil? Outer Shield Type: Tape Outer Shield Material: Aluminum Foil-Polyester Tape Outer Shield %Coverage: 100 % OUTER SHIELD DRAIN WIRE : Outer Shield Drain Wire AWG: 18 Outer Shield Drain Wire Stranding: 7x26 Outer Shield Drain Wire Conductor Material: TC - Tinned Copper OUTER JACKET : Outer Jacket Material: PVC - Polyvinyl Chloride Outer Jacket Nominal Wall Thickness: .065 in. Outer Jacket Ripcord: Yes OVERALL NOMINAL DIAMETER : Overall Nominal Diameter: .807 in. MECHANICAL CHARACTERISTICS : Operating Temperature Range: -35°C To +75°C Bulk Cable Weight: 263.5 lbs/1000 ft. Max. Recommended Pulling Tension: 418.4 lbs. Min. Bend Radius (Install): 8 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE : APPLICABLE STANDARDS : NEC/(UL) Specification: CM CEC/C(UL) Specification: CM EU CE Mark (Y/N): Yes EU RoHS Compliant (Y/N): Yes EU RoHS Compliance Date (mm/dd/yyyy):: 01/01/2004 PLENUM/NON-PLENUM : Plenum (Y/N): N
ELECTRICAL CHARACTERISTICS : Nom. Characteristic Impedance: 50 Ω Nom. Inductance: .18 ?H/ft Nom. Capacitance Conductor to Conductor @ 1 KHz: 31 pF/ft Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz: 58 pF/ft Nominal Velocity of Propagation: 66 % Nom. Conductor DC Resistance @ 20 Deg. C: 23.3 Ω/1000 ft Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 15.9 Ω/1000 ft Max. Operating Voltage - UL: 300 V RMS Max. Recommended Current: 1.05 Amps per conductor @ 25°C NOTE:Price per meter |
A P P L I C A T I O N
Analogue audio
Any analogue audio transmissions as well in fixed installations as on stage
or broadcast
These highly flexible multi-pairs are destined to mobile applications
P R O D U C T A D V A N T A G E S
High flexibility
Transmission on important lengths due to 0,22 mm2
Facility of wiring thanks to conductors cross section colored
and numbered pairs
T E C H N I C A L D A T A
NO. OF CONDUCTORS: No. x 2 x 0,22 mm2 Bare copper
COMPOSITION: 28 x 0,10 mm
CONDUCTOR INSULATION: Polyolefin
SHIELDING BY PAIR: Bare copper spiral
COLOR OF PAIR: See board
JACKET: Black PVC
PACKAGING: Per m
SUITABLE PLUG: XLR, jack, cinch
PRICE PER METER
|
24 AWG stranded (7x32) TC conductor, polyolefin insulation, individually shielded Beldfoil?
(100% coverage) numbered/color-coded PVC jackets, jackets and shields bonded to strip
simultaneously, overall Beldfoil shield and 24 AWG TC drain wire.
PHYSICAL CHARACTERISTICS :
CONDUCTOR :
Number of Pairs: 8
Total Number of Conductors: 16
AWG: 24
Stranding: 7x32
Conductor Diameter: .024 in.
Conductor Material: TC - Tinned Copper
INSULATION :
Insulation Material: PO - Polyolefin
Nom. Insulation Wall Thickness: .008 in.
Insulation Diameter: .040 in.
Lay Length: 1.75 in.
Twists/ft.: 6.85
Pair Color Code Chart: Red & Black
INNER SHIELD :
Inner Shield Material Trade Name: Beldfoil?
Inner Shield Type: Tape
Inner Shield Material: Aluminum Foil-Polyester Tape
Inner Shield % Coverage: 100 %
Inner Shield Drain Wire AWG: 24
Inner Shield Drain Wire Stranding: 7x32
Inner Shield Drain Wire Conductor Material: TC - Tinned Copper
INNER JACKET :
Inner Jacket Material: PVC - Polyvinyl Chloride
Inner Jacket Nominal Wall Thickness: .014 in.
Inner Jacket Diameter: .111 in.
OVERALL CABLING : Overall Cabling Color Code Chart:
Number Color
1 Brown
2 Red
3 Orange
4 Yellow
5 Green
6 Blue
7 Purple
8 Gray
OUTER SHIELD :
Outer Shield Material Trade Name: Beldfoil?
Outer Shield Type: Tape
Outer Shield Material: Aluminum Foil-Polyester Tape
Outer Shield %Coverage: 100 %
OUTER SHIELD DRAIN WIRE :
Outer Shield Drain Wire AWG: 18
Outer Shield Drain Wire Stranding: 7x26
Outer Shield Drain Wire Conductor Material: TC - Tinned Copper
OUTER JACKET :
Outer Jacket Material: PVC - Polyvinyl Chloride
Outer Jacket Nominal Wall Thickness: .033 in.
Outer Jacket Ripcord: Yes
OVERALL NOMINAL DIAMETER :
Overall Nominal Diameter: .452 in.
MECHANICAL CHARACTERISTICS :
Operating Temperature Range: -35°C To +75°C
Bulk Cable Weight: 103.5 lbs/1000 ft.
Max. Recommended Pulling Tension: 152 lbs.
Min. Bend Radius (Install): 4.5 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE :
APPLICABLE STANDARDS :
NEC/(UL) Specification: CM
CEC/C(UL) Specification: CM
EU CE Mark (Y/N): Yes
EU RoHS Compliant (Y/N): Yes
EU RoHS Compliance Date (mm/dd/yyyy):: 01/01/2004
PLENUM/NON-PLENUM :
Plenum (Y/N): N
ELECTRICAL CHARACTERISTICS :
Nom. Inductance: .18 ?H/ft
Nom. Capacitance Conductor to Conductor @ 1 KHz: 31 pF/ft
Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz: 58 pF/ft
Nominal Velocity of Propagation: 66 %
Nom. Conductor DC Resistance @ 20 Deg. C: 23.3 Ω/1000 ft
Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 15.9 Ω/1000 ft
Max. Operating Voltage - UL: 300 V RMS
Max. Recommended Current: 1.05 Amps per conductor @ 25°C