Content |
A P P L I C A T I O N
Analogue audio
Any analogue audio transmissions as well in fixed installations as on stage
or broadcast
These highly flexible multi-pairs are destined to mobile applications
P R O D U C T A D V A N T A G E S
High flexibility
Transmission on important lengths due to 0,22 mm2
Facility of wiring thanks to conductors cross section colored
and numbered pairs
T E C H N I C A L D A T A
NO. OF CONDUCTORS: No. x 2 x 0,22 mm2 Bare copper
COMPOSITION: 28 x 0,10 mm
CONDUCTOR INSULATION: Polyolefin
SHIELDING BY PAIR: Bare copper spiral
COLOR OF PAIR: See board
JACKET: Black PVC
PACKAGING: Per m
SUITABLE PLUG: XLR, jack, cinch
PRICE PER METER
|
24 AWG stranded (7x32) TC conductor, polyolefin insulation, individually shielded Beldfoil? (100% coverage) numbered/color-coded PVC jackets, jackets and shields bonded to strip simultaneously, overall Beldfoil shield and 24 AWG TC drain wire. PHYSICAL CHARACTERISTICS :
CONDUCTOR : Number of Pairs: 16 Total Number of Conductors: 32 AWG: 24 Stranding: 7x32 Conductor Diameter: .024 in. Conductor Material: TC - Tinned Copper INSULATION : Insulation Material: PO - Polyolefin Nom. Insulation Wall Thickness: .008 in. Insulation Diameter: .040 in. Lay Length: 1.75 in. Twists/ft.: 6.85 Pair Color Code Chart: Red and Black INNER SHIELD : Inner Shield Material Trade Name: Beldfoil? Inner Shield Type: Tape Inner Shield Material: Aluminum Foil-Polyester Tape Inner Shield % Coverage: 100 % Inner Shield Drain Wire AWG: 24 Inner Shield Drain Wire Stranding: 7x32 Inner Shield Drain Wire Conductor Material: TC - Tinned Copper INNER JACKET : Inner Jacket Material: PVC - Polyvinyl Chloride Inner Jacket Nominal Wall Thickness: .014 in. Inner Jacket Diameter: .111 in. Inner Jacket Color Code Chart: Number Color 1 Brown 2 Red 3 Orange 4 Yellow 5 Green 6 Blue 7 Purple 8 Gray 9 White Number Color 10 Black 11 Tan 12 Pink 13 Gray/Brown 14 Gray/Red 15 Gray/Orange 16 Gray/Yellow OUTER SHIELD : Outer Shield Material Trade Name: Beldfoil? Outer Shield Type: Tape Outer Shield Material: Aluminum Foil-Polyester Tape Outer Shield %Coverage: 100 % OUTER SHIELD DRAIN WIRE : Outer Shield Drain Wire AWG: 18 Outer Shield Drain Wire Stranding: 7x26 Outer Shield Drain Wire Conductor Material: TC - Tinned Copper OUTER JACKET : Outer Jacket Material: PVC - Polyvinyl Chloride Outer Jacket Nominal Wall Thickness: .056 in. Outer Jacket Ripcord: Yes OVERALL NOMINAL DIAMETER : Overall Nominal Diameter: .628 in. MECHANICAL CHARACTERISTICS : Operating Temperature Range: -35°C To +75°C Bulk Cable Weight: 177.3 lbs/1000 ft. Max. Recommended Pulling Tension: 286.4 lbs. Min. Bend Radius (Install): 6.5 in. APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE : APPLICABLE STANDARDS : NEC/(UL) Specification: CM CEC/C(UL) Specification: CM EU CE Mark (Y/N): Yes EU RoHS Compliant (Y/N): Yes EU RoHS Compliance Date (mm/dd/yyyy):: 01/01/2004 PLENUM/NON-PLENUM : Plenum (Y/N): N ELECTRICAL CHARACTERISTICS : Nom. Characteristic Impedance: 50 Ω Nom. Inductance: .18 ?H/ft Nom. Capacitance Conductor to Conductor @ 1 KHz: 31 pF/ft Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz: 58 pF/ft Nominal Velocity of Propagation: 66 % Nom. Conductor DC Resistance @ 20 Deg. C: 23.3 Ω/1000 ft Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 15.9 Ω/1000 ft Max. Operating Voltage - UL: 300 V RMS Max. Recommended Current: 1.05 Amps per conductor @ 25°C |
24 AWG stranded (7x32) TC conductor, polyolefin insulation, individually shielded Beldfoil? (100% coverage) numbered/color-coded PVC jackets, jackets and shields bonded to strip simultaneously, overall Beldfoil shield and 24 AWG TC drain wire. PHYSICAL CHARACTERISTICS :
CONDUCTOR : Number of Pairs: 24 Total Number of Conductors: 48 AWG: 24 Stranding: 7x32 Conductor Diameter: .024 in. Conductor Material: TC - Tinned Copper INSULATION : Insulation Material: PO - Polyolefin Nom. Insulation Wall Thickness: .008 in. Insulation Diameter: .040 in. Lay Length: 1.75 in. Twists/ft.: 6.85 Pair Color Code Chart: Red and Black INNER SHIELD : Inner Shield Material Trade Name: Beldfoil? Inner Shield Type: Tape Inner Shield Material: Aluminum Foil-Polyester Tape Inner Shield % Coverage: 100 % Inner Shield Drain Wire AWG: 24 Inner Shield Drain Wire Stranding: 7x32 Inner Shield Drain Wire Conductor Material: TC - Tinned Copper INNER JACKET : Inner Jacket Material: PVC - Polyvinyl Chloride Inner Jacket Nominal Wall Thickness: .014 in. Inner Jacket Diameter: .111 in. Inner Jacket Color Code Chart: Number Color 1 Brown 2 Red 3 Orange 4 Yellow 5 Green 6 Blue 7 Purple 8 Gray 9 White 10 Black 11 Tan 12 Pink 13 Gray/Brown Number Color 14 Gray/Red 15 Gray/Orange 16 Gray/Yellow 17 Gray/Green 18 Gray/Blue 19 Gray/Purple 20 Gray/Gray 21 Gray/White 22 Gray/Black 23 Gray/Tan 24 Gray/Pink OUTER SHIELD : Outer Shield Material Trade Name: Beldfoil? Outer Shield Type: Tape Outer Shield Material: Aluminum Foil-Polyester Tape Outer Shield %Coverage: 100 % OUTER SHIELD DRAIN WIRE : Outer Shield Drain Wire AWG: 18 Outer Shield Drain Wire Stranding: 7x26 Outer Shield Drain Wire Conductor Material: TC - Tinned Copper OUTER JACKET : Outer Jacket Material: PVC - Polyvinyl Chloride Outer Jacket Nominal Wall Thickness: .065 in. Outer Jacket Ripcord: Yes OVERALL NOMINAL DIAMETER : Overall Nominal Diameter: .807 in. MECHANICAL CHARACTERISTICS : Operating Temperature Range: -35°C To +75°C Bulk Cable Weight: 263.5 lbs/1000 ft. Max. Recommended Pulling Tension: 418.4 lbs. Min. Bend Radius (Install): 8 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE : APPLICABLE STANDARDS : NEC/(UL) Specification: CM CEC/C(UL) Specification: CM EU CE Mark (Y/N): Yes EU RoHS Compliant (Y/N): Yes EU RoHS Compliance Date (mm/dd/yyyy):: 01/01/2004 PLENUM/NON-PLENUM : Plenum (Y/N): N
ELECTRICAL CHARACTERISTICS : Nom. Characteristic Impedance: 50 Ω Nom. Inductance: .18 ?H/ft Nom. Capacitance Conductor to Conductor @ 1 KHz: 31 pF/ft Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz: 58 pF/ft Nominal Velocity of Propagation: 66 % Nom. Conductor DC Resistance @ 20 Deg. C: 23.3 Ω/1000 ft Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 15.9 Ω/1000 ft Max. Operating Voltage - UL: 300 V RMS Max. Recommended Current: 1.05 Amps per conductor @ 25°C NOTE:Price per meter | The DAP audio mulitpairs are extremely flexible and rugged, suitable for very difficult environments, Studio, Stage and above all in –on the road" use. The inner conductors are double colour coded and shielded with alufoil, each pair XLPE Isolated and numbered.
• Single shielded multicable
• colour coded
• Tough, roadproof quality
• Each pair OFC-copper shielded
1. Masterjacket: Dark blue flexible roadproof PVC
2. Separator: Twistet cotton paper
3. Pairjacket: Numbered dark-blue PVC 3 mmØ
4. Pairshield: Silvercoatet Alufoil
5. Conductor insulation: Polyethelene red and white 1mmØ
6. Inner conductor: Oxigene free copper 99,997 OFC
7. Earth drainwire: Tinned copper
Each pair with alu-foil (OFC Copper), with exception of MK-3222.
Min. orderquantuty: 1m.
Max. on drum: 500m.
Technical Info
Number of pairs: 36
Conductor insulation Ø in mm.: PE, red+white, 1,0
Pair jacket Ø in mm.: PVC blue, (numbered), 3,0
Pair shield: Alufoil+tinned drainwire
Master jacket Ø in mm.: PVC, dark blue, 26,5
Minimal bending radius: ?265
Weight (kg/100m.): 880 | A P P L I C A T I O N
Analogue audio
Fixed installations
Audio transmissions in noisy environment
Wiring in professional sound studios
P R O D U C T A D V A N T A G E S
Very good protection against electromagnetique interferences
thanks to individually shielded pairs and overall shield
T E C H N I C A L D A T A
NO. OF CONDUCTORS: No. x 2 x 0,22 mm2 Tinned copper
CONDUCTOR INSULATION: PE
SHIELDING BY PAIR: Aluminium polyester foil + drain wire
COLOR OF CONDUCTEUR: White / blue
COLOR OF PAIR: By number
OVERALLSHIELD: Aluminium polyester foil + drain wire
JACKET: Black PVC
PACKAGING: Per m
SUITABLE PLUG: XLR, jacks
PRICE PER METER | Adam Hall Cables 4 STAR HPD 325 Hybrid Cable Power & DMX 3 x 2.5 mm² & 2 x 0.22 mm². Price per meter
Type
Power / Signal Cable
Temperature range
-20 - 70 °C
Power
Number of internal conductors
3
Center conductor cross section
2.5 mm²
Center conductor construction
96 x 0.10 mm
Center conductor material
OFC
DMX
Number of inner conductors 2
2
Center conductor cross section 2
0.22 mm²
Center conductor construction 2
7 x 0.20 mm
Center conductor material 2
OFC
Shield
Aluminium foil, Copper spiral coil shield
Conductor resistance 2
85 ohm/km
|
Reviews
There are no reviews yet.