Content |
Quality Cable MADE IN FRANCE
PRICE PER METER
A P P L I C A T I O N
DMX signal and digital AES / EBU transmissions
Power Cable for the lights
Wiring in mobile and fixed applications
P R O D U C T A D V A N T A G E S
Digital transmission over long distances
High flexibility
Very good protection against electrical interferences due to double
shielding
T E C H N I C A L D A T A
DMX 512 CABLE
NO. OF CONDUCTORS: 2 x 2 x 0,34 mm2 Tinned copper – AWG22
CONDUCTOR INSULATION: PE
1ST SHIELDING: Aluminium foil + drain wire
2ND SHIELDING: Tinned copper braid
JACKET: Grey PVC
DIAMETER: 7 mm
POWER CABLE
NO. OF CONDUCTORS: 3 G 1.5 mm2 Bare copper
CONDUCTOR INSULATION: PVE
COLOUR CODING: Brown - Blue - Green / Yellow
ASSEMBLY
WEIGHT PER 1 KM: 255 Kg / km
PACKAGING: Per m
SUITABLE PLUG: XLR
DIAMMETER: 14mm
| Adam Hall Cables 5 STAR D 234 DMX, AES/EBU Cable 110 Ohms Digital 2 x 0.34 mm². Price per meter
The 5 STAR D234 is our classic if you need a DMX, AES/EBU cable with excellent transmission properties and it should also be extremely robust, which is especially helpful with sharp-edged light trusses. It is very well protected against electrical influences thanks to its shielding factor of 100%.
Center conductor cross section
0.34 mm²
Center conductor material
OFC
Center conductor construction
19 x 0.15 mm
Number of internal conductors
2
Shield material
Aluminium fleece
Line resistance
53 Ohm(s)
Temperature range
-25 - 70 °C
Additional information
Bulk Cable
|
24 AWG stranded (7x32) TC conductor, polyolefin insulation, individually shielded Beldfoil?
(100% coverage) numbered/color-coded PVC jackets, jackets and shields bonded to strip
simultaneously, overall Beldfoil shield and 24 AWG TC drain wire.
PHYSICAL CHARACTERISTICS :
CONDUCTOR :
Number of Pairs: 8
Total Number of Conductors: 16
AWG: 24
Stranding: 7x32
Conductor Diameter: .024 in.
Conductor Material: TC - Tinned Copper
INSULATION :
Insulation Material: PO - Polyolefin
Nom. Insulation Wall Thickness: .008 in.
Insulation Diameter: .040 in.
Lay Length: 1.75 in.
Twists/ft.: 6.85
Pair Color Code Chart: Red & Black
INNER SHIELD :
Inner Shield Material Trade Name: Beldfoil?
Inner Shield Type: Tape
Inner Shield Material: Aluminum Foil-Polyester Tape
Inner Shield % Coverage: 100 %
Inner Shield Drain Wire AWG: 24
Inner Shield Drain Wire Stranding: 7x32
Inner Shield Drain Wire Conductor Material: TC - Tinned Copper
INNER JACKET :
Inner Jacket Material: PVC - Polyvinyl Chloride
Inner Jacket Nominal Wall Thickness: .014 in.
Inner Jacket Diameter: .111 in.
OVERALL CABLING : Overall Cabling Color Code Chart:
Number Color
1 Brown
2 Red
3 Orange
4 Yellow
5 Green
6 Blue
7 Purple
8 Gray
OUTER SHIELD :
Outer Shield Material Trade Name: Beldfoil?
Outer Shield Type: Tape
Outer Shield Material: Aluminum Foil-Polyester Tape
Outer Shield %Coverage: 100 %
OUTER SHIELD DRAIN WIRE :
Outer Shield Drain Wire AWG: 18
Outer Shield Drain Wire Stranding: 7x26
Outer Shield Drain Wire Conductor Material: TC - Tinned Copper
OUTER JACKET :
Outer Jacket Material: PVC - Polyvinyl Chloride
Outer Jacket Nominal Wall Thickness: .033 in.
Outer Jacket Ripcord: Yes
OVERALL NOMINAL DIAMETER :
Overall Nominal Diameter: .452 in.
MECHANICAL CHARACTERISTICS :
Operating Temperature Range: -35°C To +75°C
Bulk Cable Weight: 103.5 lbs/1000 ft.
Max. Recommended Pulling Tension: 152 lbs.
Min. Bend Radius (Install): 4.5 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE :
APPLICABLE STANDARDS :
NEC/(UL) Specification: CM
CEC/C(UL) Specification: CM
EU CE Mark (Y/N): Yes
EU RoHS Compliant (Y/N): Yes
EU RoHS Compliance Date (mm/dd/yyyy):: 01/01/2004
PLENUM/NON-PLENUM :
Plenum (Y/N): N
ELECTRICAL CHARACTERISTICS :
Nom. Inductance: .18 ?H/ft
Nom. Capacitance Conductor to Conductor @ 1 KHz: 31 pF/ft
Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz: 58 pF/ft
Nominal Velocity of Propagation: 66 %
Nom. Conductor DC Resistance @ 20 Deg. C: 23.3 Ω/1000 ft
Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 15.9 Ω/1000 ft
Max. Operating Voltage - UL: 300 V RMS
Max. Recommended Current: 1.05 Amps per conductor @ 25°C
NOTE:Price per meter
|
24 AWG stranded (7x32) TC conductor, polyolefin insulation, individually shielded Beldfoil? (100% coverage) numbered/color-coded PVC jackets, jackets and shields bonded to strip simultaneously, overall Beldfoil shield and 24 AWG TC drain wire. PHYSICAL CHARACTERISTICS :
CONDUCTOR : Number of Pairs: 16 Total Number of Conductors: 32 AWG: 24 Stranding: 7x32 Conductor Diameter: .024 in. Conductor Material: TC - Tinned Copper INSULATION : Insulation Material: PO - Polyolefin Nom. Insulation Wall Thickness: .008 in. Insulation Diameter: .040 in. Lay Length: 1.75 in. Twists/ft.: 6.85 Pair Color Code Chart: Red and Black INNER SHIELD : Inner Shield Material Trade Name: Beldfoil? Inner Shield Type: Tape Inner Shield Material: Aluminum Foil-Polyester Tape Inner Shield % Coverage: 100 % Inner Shield Drain Wire AWG: 24 Inner Shield Drain Wire Stranding: 7x32 Inner Shield Drain Wire Conductor Material: TC - Tinned Copper INNER JACKET : Inner Jacket Material: PVC - Polyvinyl Chloride Inner Jacket Nominal Wall Thickness: .014 in. Inner Jacket Diameter: .111 in. Inner Jacket Color Code Chart: Number Color 1 Brown 2 Red 3 Orange 4 Yellow 5 Green 6 Blue 7 Purple 8 Gray 9 White Number Color 10 Black 11 Tan 12 Pink 13 Gray/Brown 14 Gray/Red 15 Gray/Orange 16 Gray/Yellow OUTER SHIELD : Outer Shield Material Trade Name: Beldfoil? Outer Shield Type: Tape Outer Shield Material: Aluminum Foil-Polyester Tape Outer Shield %Coverage: 100 % OUTER SHIELD DRAIN WIRE : Outer Shield Drain Wire AWG: 18 Outer Shield Drain Wire Stranding: 7x26 Outer Shield Drain Wire Conductor Material: TC - Tinned Copper OUTER JACKET : Outer Jacket Material: PVC - Polyvinyl Chloride Outer Jacket Nominal Wall Thickness: .056 in. Outer Jacket Ripcord: Yes OVERALL NOMINAL DIAMETER : Overall Nominal Diameter: .628 in. MECHANICAL CHARACTERISTICS : Operating Temperature Range: -35°C To +75°C Bulk Cable Weight: 177.3 lbs/1000 ft. Max. Recommended Pulling Tension: 286.4 lbs. Min. Bend Radius (Install): 6.5 in. APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE : APPLICABLE STANDARDS : NEC/(UL) Specification: CM CEC/C(UL) Specification: CM EU CE Mark (Y/N): Yes EU RoHS Compliant (Y/N): Yes EU RoHS Compliance Date (mm/dd/yyyy):: 01/01/2004 PLENUM/NON-PLENUM : Plenum (Y/N): N ELECTRICAL CHARACTERISTICS : Nom. Characteristic Impedance: 50 Ω Nom. Inductance: .18 ?H/ft Nom. Capacitance Conductor to Conductor @ 1 KHz: 31 pF/ft Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz: 58 pF/ft Nominal Velocity of Propagation: 66 % Nom. Conductor DC Resistance @ 20 Deg. C: 23.3 Ω/1000 ft Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 15.9 Ω/1000 ft Max. Operating Voltage - UL: 300 V RMS Max. Recommended Current: 1.05 Amps per conductor @ 25°C | 22 AWG stranded (7x30) .030" bare copper conductor, foam polyethylene
insulation, bare copper braid shield (95% coverage), PVC jacket.
PHYSICAL CHARACTERISTICS :
CONDUCTOR :
Number of Coax: 1
Total Number of Conductors: 1
RG Type: 59/U
AWG: 22
Stranding: 7x30
Conductor Diameter: .030 in.
Conductor Material: BC - Bare Copper
INSULATION :
Insulation Material: FPE - Foam Polyethylene
Insulation Diameter: .146 in.
OUTER SHIELD :
Outer Shield Type: Braid
Outer Shield Material: BC - Bare Copper
Outer Shield %Coverage: 95 %
OUTER JACKET :
Outer Jacket Material: PVC - Polyvinyl Chloride
OVERALL NOMINAL DIAMETER :
Overall Nominal Diameter: .241 in.
MECHANICAL CHARACTERISTICS :
Operating Temperature Range: -40°C To +80°C
Non-UL Temperature Rating: 80°C
Bulk Cable Weight: 33 lbs/1000 ft.
Max. Recommended Pulling Tension: 65 lbs.
Min. Bend Radius (Install): 2.5 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE :
APPLICABLE STANDARDS :
NEC/(UL) Specification: CM
CEC/C(UL) Specification: CM
AWM Specification: UL Style 1354 (30 V 80°C)
EU CE Mark (Y/N): Yes
EU RoHS Compliant (Y/N): Yes
EU RoHS Compliance Date (mm/dd/yyyy):: 01/01/2004
FLAME TEST :
UL Flame Test: UL1685 UL Loading
SUITABILITY :
Suitability - Indoor: Yes
Suitability - Outdoor: Yes
PLENUM/NON-PLENUM :
Plenum (Y/N): N
Plenum Number: 89259 or 82259
ELECTRICAL CHARACTERISTICS :
Nom. Characteristic Impedance: 75 Ω
Nom. Inductance: .09 ?H/ft
Nom. Capacitance Conductor to Shield: 17.3 pF/ft
Nominal Velocity of Propagation: 78 %
Nominal Delay: 1.3 ns/ft
Nom. Conductor DC Resistance @ 20 Deg. C: 15 Ω/1000 ft
Nominal Outer Shield DC Resistance @ 20°C: 2.6 Ω/1000 ft
Nom. Attenuation:
Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Nom. Attenuation (dB/100 ft.)
1 .30
5 .65
10 .90
50 2.1
100 3.0
200 4.5
400 6.6
700 8.9
900 10.1
1000 10.9
Max. Operating Voltage - UL: 300 V RMS
NOTES : Notes: For CCTV Applications.
NOTE: Price per meter |
23 AWG solid .023" bare copper or bare copper-covered conductor, polyethylene insulation, bare copper braid shield (95% coverage), PVC jacket. PHYSICAL CHARACTERISTICS : CONDUCTOR : Number of Coax: 1 Total Number of Conductors: 1 RG Type: 59/U AWG: 23 Stranding: Solid Conductor Diameter: .023 in. Conductor Material: BC - Bare Copper INSULATION : Insulation Material: PE - Polyethylene Insulation Diameter: .146 in. OUTER SHIELD : Outer Shield Type: Braid Outer Shield Material: BC - Bare Copper Outer Shield %Coverage: 95 % OUTER JACKET : Outer Jacket Material: PVC - Polyvinyl Chloride OVERALL NOMINAL DIAMETER : Overall Nominal Diameter: .242 in. MECHANICAL CHARACTERISTICS : Operating Temperature Range: -20°C To +80°C UL Temperature Rating: 80°C (UL AWM Style 1354) Bulk Cable Weight: 36 lbs/1000 ft. Max. Recommended Pulling Tension: 62 lbs. Min. Bend Radius (Install): 2.5 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE : APPLICABLE STANDARDS : NEC/(UL) Specification: CM CEC/C(UL) Specification: CM AWM Specification: UL Style 1354 (30 V 80°C) EU CE Mark (Y/N): No EU RoHS Compliant (Y/N): Yes EU RoHS Compliance Date (mm/dd/yyyy):: 01/01/2004 FLAME TEST : UL Flame Test: UL1685 UL Loading SUITABILITY : Suitability - Indoor: Yes Suitability - Outdoor: Yes PLENUM/NON-PLENUM : Plenum (Y/N): N ELECTRICAL CHARACTERISTICS : Nom. Characteristic Impedance: 75 Ω Nom. Inductance: .131 ?H/ft Nom. Capacitance Conductor to Shield: 20.5 pF/ft Nominal Velocity of Propagation: 66 % Nominal Delay: 1.54 ns/ft Nom. Conductor DC Resistance @ 20 Deg. C: 20.4 Ω/1000 ft Nominal Outer Shield DC Resistance @ 20°C: 2.9 Ω/1000 ft Nom. Attenuation: Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Nom. Attenuation (dB/100 ft.) 1 .4 10 1.1 50 2.4 100 3.4 200 4.9 400 7.0 700 9.7 900 11.1 1000 12.0 Max. Power Rating: Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Max. Power Rating (W) 50 470 100 310 300 160 500 115 1000 76 Max. Operating Voltage - UL: 30 V RMS (UL AWM Style 1354); 300 V RMS Max. Operating Voltage - Non-UL: 1700 V RMS
NOTES : Notes: RG-59/U Type standard Analog Video Coax. CM Rated Version of 8241.
NOTE:Price per meter |