Content |
| - 9 CHANNEL INPUT, 1 CHANNEL FOR MASTER OUTPUT, 2 CHANNEL FOR SUB OUTPUT, 1 CHANNEL FOR RECORDING OUTPUT 9 channel input and 1 channel for master output and 2 sub channel for flexible use and 1 channel for recording output which is not affected by the master level fader built in. - AUXILIARY INPUT AND PRIORITY INPUT Auxiliary Input is built in so that users can use the external sound source in there convenience and the sound source connected to 2 channels of this priority input is played prior to the other input. - EQ ON EACH CHANNEL 3 band (High, Mid, Low) Graphic equalizers are built-in so that a user can adjust the tone of sound to there taste. - PHANTOM POWER Phantom powers are available on channel 1 and 2 for the condenser microphone. - DUCKING Ducking function available on channel 1 and 2 enable their sound source to be broadcast prior to the others. A user can select whether to use it or not. | | | | | PP-613 | Rated Output (1kHz) | Master Output | +4dBm/600Ω, BAL | SUB 1,2 Output | +4dBm/600Ω, UNBAL | REC Output | +10dBm/10KΩ, UNBAL | Input Sensitivity /Impedance | MIC (CH1~CH9) | -60dBm/600Ω, BAL | LINE(CH1~CH6) | -20dBm/47kΩ, BAL | LINE(CH7~CH9) | -20dBm/47kΩ, UNBAL | AUX 1,2 | 10dBm/20kΩ, UNBAL | Priority 1,2 | 0dBm/20kΩ, UNBAL | Insert | 0dBm/20kΩ, UNBAL | T.H.D | Less than 0.3% | Frequency Response | 30Hz-20kHz (+1dB,-3dB) | Input Channel Equalizer | HIGH | ±12dB (10kHz) | MID | ±12dB (1kHz) | LOW | ±12dB (100kHz) | Output Channel Equalizer | HIGH | ±12dB (10kHz) | HI-MID | ±12dB (2kHz) | LOW-MID | ±12dB (400kHz) | LOW | ±12dB (80kHz) | Residual Noise (at V/R min) | Less than -90dB | Crosstalk | Less than -50dB | Phantom Power | +18V DC | Operation Temperature | -10℃~+40℃ | Power Source | 100-120VAC or 220-240VAC; 50/60Hz (Supplied AC mains transformer depends on country requirements) | Power Consumption | 10W | Weight(SET) | 5.5Kg/21.1Ib | Dimension(SET) | 482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in | ※ Specifications and design subject to change without notice. | | | |
|
The ATT-30 from Inter-M Americas is a one-gang wall panel attenuator. The knob has four clearly-labeled steps to make easy adjustments. A screwless terminal block simplifies installation, and the sleek, modern design fits into any environment. The attenuator can handle up to 30W. |
| - AUTOMATIC CHARGING Tapered charging circuitry charges your backup batteries without risk of overcharging. - EASY BATTERY MONITORING Integrated digital volt meter and digital ampere meter allow you to monitor the status of your batteries. | | | | | PB-607 | Battery Requirement | 24V DC | Starting Current | 3A Max. | Charge Complete Voltage | 27.3V ±10% | Operation Temperature | -10℃~+40℃ | Power Source | 100-120VAC or 220-240VAC; 50/60Hz (Supplied AC mains transformer depends on country requirements) | Power Consumption | 130W | Weight(SET) | 7Kg/15.4Ib | Dimension(SET) | 482(W) x 88(H) x 280(D)mm/19(W) x 3.5(H) x 11(D)in | | | |
|
- PRIORITY CONTROL It controls the priority of emergency, timer, remote1, remote2, main(normal). - AUTO FIRE SENSOR The fire alarm will be given automatically to the designated areas by detecting fire sensor input. - SPEAKER SWITCHING ON EMERGENCY OR NORMAL(MAIN) You can control the speaker relay on emergency or normal(main) mode by using the speaker switch on front panel. - DISPLAY STATUS You can easily check the priority status. - 2 AND 3 WIRE SPEAKER LINE SYSTEM You can control the speaker line on the 2 wire system or 3 wire system. - EXTENSION FUNCTION You can easily expand by connecting additional ECS-616.
ECS-616 | Priority Control | Emergency >Timer > Remote1 > Remote2 > Main | Link in/ out Interface | RS-422(19200bps,Data 8bits,Stop 1bit, Non Parity bit, Start1bit) | Link in/ out interface Distance | 1.2 km | Operation Temperature | -10 °C ~+ 40 °C | Power Source | 24V DC | Power Consumption | 900mA | Weight | 4.8Kg/10.6Ib | Dimensions( W x H x D) | 482(W)x 88(H) x 380(D) mm / 19(W)x 3.5(H)x 15(D)in | ※ Specifications and design subject to change without notice. |
|
The RM-210 is an extension unit for increasing the number of function keys of TOA's RM-200M, RM-200XF and RM-200X Remote Microphones.
Specification |
| Current Consumption | 20mA max. (in terms of RM-200M's DC power input 75mA max. (interms of DC power inputs of RM-200X and RM-200XF) | Connection | Connection to RM-200M, RM-200X or RM-200XF by way of dedicated Cable | Number of Function | Keys 10 | Function | When used to expand the RM-200M:
Selects and activates the Voice Announcement Board messages.
When used to expand the RM-200X and RM-200XF (PC software setting):
Emergency activation, emergency reset, BGM pattern selection, EV message activation, broadcast zone selection, monitor zone selection, chime activation, Talk switch activation, control output activation, input volume adjustment, zone volume adjustment, and failure output indication and reset. | Finish | ABS resin, bluish gray (PANTON 538 or its equivalent) | Dimensions | 110 (W) x 76.5 (H) x 215 (D)mm | Weight | 350g | Accessory | Extension cable x 1, Linkage bracket A x 1, Linkage bracket B x 1, Screw for linkage bracket x 12 |
|
Music Program Selector 1-6 with Relay
Toa - 100V installation |
Reviews
There are no reviews yet.