OSRAM 84095 L18W 2G11 Dulux L Lumilux 18W Warm white 1200Lm 4000K

5.58 incl. GR VAT

In stock

EAN: N/A
Installments calculation
CompareAdd to wishlist Submit Better Price
DULUX L 18 W/840 2G11 Electrical data Nominal wattage 18.00 W Nominal voltage 57.0 V Rated wattage 18.00 W Photometrical data Nominal luminous flux 1200 lm Light color (designation) LUMILUX Cool White Luminous flux at 1200 lm Rated luminous flux 1200 lm Rated color temperature 4000 K Color rendering index Ra ≥80 Rated LLMF at […]

 

Read more

DULUX L 18 W/840 2G11
Electrical data

Nominal wattage 18.00 W
Nominal voltage 57.0 V
Rated wattage 18.00 W

Photometrical data

Nominal luminous flux 1200 lm
Light color (designation) LUMILUX Cool White
Luminous flux at 1200 lm
Rated luminous flux 1200 lm
Rated color temperature 4000 K
Color rendering index Ra ≥80
Rated LLMF at 4,000 h 0.86
Rated LLMF at 6,000 h 0.82
Rated LLMF at 8,000 h 0.80
Rated LLMF at 12,000 h 0.76
Rated LLMF at 16,000 h 0.81
Rated LLMF at 20,000 h 0.80
Luminance 2.1 cd/cm2

Dimensions & weight

Diameter 17.5 mm
Overall length 214.5 mm
Tube diameter 17.5 mm
Length 217.0 mm
Length acc. to IEC standard 225 mm
Length with base excl. base pins/connection 217.00 mm
Outer bulb T16
Maximum diameter 17.0 mm

Temperatures & operating conditions

Rated ambient temp.w.max.luminous flux 25.0 °C

Lifespan

Nominal lamp life time 12000 h
Rated lamp life time 12000 h
Service life 13000 h
Rated lamp survival factor at 2,000 h 0.99
Rated lamp survival factor at 4,000 h 0.99
Rated lamp survival factor at 6,000 h 0.98
Rated lamp survival factor at 8,000 h 0.92
Rated lamp survival factor at 12,000 h 0.50
Rated lamp survival factor at 16,000 h 0.81
Rated lamp survival factor at 20,000 h 0.50
Operation mode LLMF/LSF HF
Lifespan 20000 h

Additional product data

Base (standard designation) 2G11
Mercury content 2.3 mg
Product remark For ECG and CCG operation

Capabilities

Dimmable Yes
Suitable for indoor Yes

Certificates & standards

Energy efficiency class To
Energy consumption 20 kWh/1000h
Weight 0.20 kg

Reviews

There are no reviews yet.

Be the first to review “OSRAM 84095 L18W 2G11 Dulux L Lumilux 18W Warm white 1200Lm 4000K”

Your email address will not be published. Required fields are marked *

Quick Comparison

OSRAM 84095 L18W 2G11 Dulux L Lumilux 18W Warm white 1200Lm 4000K removePHILIPS CDM-T/942 G12 150-SA-T 150W DISCHARGE LAMP 4200K removeGeneral Electric T11-T19P 88457 Coil tGENERAL ELECTRIC T11-T19 88457 FWR 1000W Theatre Lamp 2800-3000K 240V removeGeneral Electric T18-T25 GCV Theatre Lamp 2800-3050K 230V 500W removeGeneral Electric Par 56 GX16d NSP 240V 300W removeOsram 64745 CP24 CP70 GX9.5 230V 1000W T19/T11 remove
NameOSRAM 84095 L18W 2G11 Dulux L Lumilux 18W Warm white 1200Lm 4000K removePHILIPS CDM-T/942 G12 150-SA-T 150W DISCHARGE LAMP 4200K removeGeneral Electric T11-T19P 88457 Coil tGENERAL ELECTRIC T11-T19 88457 FWR 1000W Theatre Lamp 2800-3000K 240V removeGeneral Electric T18-T25 GCV Theatre Lamp 2800-3050K 230V 500W removeGeneral Electric Par 56 GX16d NSP 240V 300W removeOsram 64745 CP24 CP70 GX9.5 230V 1000W T19/T11 remove
Imagecdm-t 150 sa-t 942 philips lamp discharge 4200k g12
SKU8409580975T11-T19PT18-T25 GCV GEPAR56NSP64745
Rating
Price 5.58 incl. GR VAT47.11 incl. GR VAT 16.46 incl. GR VAT 16.12 incl. GR VAT 14.88 incl. GR VAT 18.35 incl. GR VAT
Stock

In stock

Only 1 left in stock (can be backordered)

In stock

In stock

Only 3 left in stock

Available on backorder

AvailabilityIn stockOnly 1 left in stock (can be backordered)In stockIn stockOnly 3 left in stockAvailable on backorder
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description
Content

DULUX L 18 W/840 2G11 Electrical data

Nominal wattage 18.00 W
Nominal voltage 57.0 V
Rated wattage 18.00 W
Photometrical data
Nominal luminous flux 1200 lm
Light color (designation) LUMILUX Cool White
Luminous flux at 1200 lm
Rated luminous flux 1200 lm
Rated color temperature 4000 K
Color rendering index Ra ≥80
Rated LLMF at 4,000 h 0.86
Rated LLMF at 6,000 h 0.82
Rated LLMF at 8,000 h 0.80
Rated LLMF at 12,000 h 0.76
Rated LLMF at 16,000 h 0.81
Rated LLMF at 20,000 h 0.80
Luminance 2.1 cd/cm2
Dimensions & weight
Diameter 17.5 mm
Overall length 214.5 mm
Tube diameter 17.5 mm
Length 217.0 mm
Length acc. to IEC standard 225 mm
Length with base excl. base pins/connection 217.00 mm
Outer bulb T16
Maximum diameter 17.0 mm
Temperatures & operating conditions
Rated ambient temp.w.max.luminous flux 25.0 °C
Lifespan
Nominal lamp life time 12000 h
Rated lamp life time 12000 h
Service life 13000 h
Rated lamp survival factor at 2,000 h 0.99
Rated lamp survival factor at 4,000 h 0.99
Rated lamp survival factor at 6,000 h 0.98
Rated lamp survival factor at 8,000 h 0.92
Rated lamp survival factor at 12,000 h 0.50
Rated lamp survival factor at 16,000 h 0.81
Rated lamp survival factor at 20,000 h 0.50
Operation mode LLMF/LSF HF
Lifespan 20000 h
Additional product data
Base (standard designation) 2G11
Mercury content 2.3 mg
Product remark For ECG and CCG operation
Capabilities
Dimmable Yes
Suitable for indoor Yes
Certificates & standards
Energy efficiency class To
Energy consumption 20 kWh/1000h
Colour: (Ra8) 96 Colour Temp.: 4200K Type: CDM-T150/942 DE/SE: SE Lumen: 12100 Voltage: 96V Watt: 150W Lifetime/H: 12000 Box Quant: 12 OAL: 110mm Length: 9 mm Diameter: 20 mm LCL: 56 mm Burning pos.: Any Socket: G12 Made in Belgium

General Electric Theatre Lamp 2800-3000K 240V-1000W

Volts:240
Watts:1000
Hours:750
Temperature:3200K
Base:GX9,5

General Electric Theatre Lamp 2800-3000K 230V-500W

  • Watt : 500
  • Base : GY 9.5 
  • Lumen : 11.000
  • Lamp Life : 400 h
  • Temperature : 3.050K
  • Volt : 240

 

Par 56 GX16d NSP 240V 300W

Technical Info

Colour Temp.: 3200
Voltage: 240V
Watt: 300W
Lifetime/H: 2000
Box Quant.: 12
Beam: NSP
Socket: GX16d

Product features
  • Operation at mains voltage: 120 V | 230 V | 240 V
  • Color temperature: 3,000 K (with longer lifespan)
  • Color temperature: 3,200 K (for professional film and TV work)
Areas of application
  • Professional film and TV work
  • Theater and concert stages
  • Entertainment
Safety advice To prevent personal injury or damage to property, halogen lamps may only be operated in suitable luminaires designed with suitable mechanisms (protective shields, grids, etc.) to ensure that in the event of a lamp bursting no parts/shards can escape and that during operation no ultraviolet radiation can escape. There must also be a warning sign to indicate that the lamps give off high levels of heat. Detailed information is available on request.
Photometrical data
Color temperature 3200 K
Dimensions & weight
Diameter 26.0 mm
Length 110.0 mm
Light center length (LCL) 55.0 mm
Illuminated field 13.0*15.0 mm²
Filament diameter 15.0 mm
Lifespan
Lifespan 200 h
Additional product data
Base (standard designation) GX9.5
Capabilities
Burning position s90
Certificates & standards
EEI – Energy Label B
Country specific categorizations
ANSI code FVA
LIF CP/70
Order reference 64745
Electrical data
Nominal wattage 1000.00 W
Nominal voltage 240 V
Weight0.20 kg0.50 kg0.30 kg0.30 kg.8 kg0.50 kg
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Weight 0.20 kg
Weight 0.50 kg
Weight 0.30 kg
Weight 0.30 kg
Weight .8 kg
Weight 0.50 kg