Content | 4ArXS (“For Architainment eXtreme Seal”) HSD light sources are particularly powerful metal halide lamps that are setting new standards in the architainment sector. Easy maintenance, high load capacity and long life open up new possibilities for creative architectural and effect lighting.
Nominal wattage 150 W
Nominal voltage 92.5 V
Lamp voltage 97 V
Nominal current 1.6 A
Lamp current 1.6 ANominal luminous flux 12000 lm
Color temperature 7000 K
Diameter 20 mm
Length 105 mm
Light center length (LCL) 56 mm
Lifespan 3000 h
Base (standard designation) G12
Product remark Outer bulb with UV filter
Burning position hs30
EEI - Energy Label C
Dimmable |
no |
Energy efficiency class |
C |
Base/Sockel |
G12 |
Wattage - (W) |
150 |
Luminous flux - (lm) |
12000 |
Luminous efficacy - (lm / W) |
80 |
Color temperature - (K) |
7000 |
Energy consumption - (kWh / 1000h) |
150 |
Lifetime - (h) |
3000 |
|
General Electric Theatre Lamp 2800-3000K 230V-500W
- Watt : 500
- Base : GY 9.5
- Lumen : 11.000
- Lamp Life : 400 h
- Temperature : 3.050K
- Volt : 240
|
Par 64 GX16d NSP SuperCP87 240V 500W
Technical Info
Color-Temp.: 3200 Type: SuperCP87 Voltage: 240V Watt: 500W Lifetime/H: 300 Box Quant.: 6 Beam: NSP Beam angle: 9x11 Socket: GX16d | Par 36 Sealdbeam G53 Screw VNSP 6,4V 30W
Technical Info
Type: 4515
Voltage: 6,4V
Watt: 30W
Lifetime/H: 100
Temp : 3000K
Beam: VNSP
Beam angle: 5,5x4
Socket: Screw |
Metal halide light
- Single ended
- Colour temperature: 5,600°K
- Luminous flux: 47,000 Lm
- GY9.5 Base
- Average rated life: 500 Hours
- Intended use of lamp: Is intended for use in stage and theatre surroundings
- Is not suitable for household lighting
Further Information
Construction Type |
Single pin socket |
Power in Watts |
700 W |
Socket |
GY9.5 |
Color / Color temperature [K] |
5600 ° |
Type |
MSR |
| Product features
- Operation at mains voltage: 120 V | 230 V | 240 V
- Color temperature: 3,000 K (with longer lifespan)
- Color temperature: 3,200 K (for professional film and TV work)
Areas of application
- Professional film and TV work
- Theater and concert stages
- Entertainment
Safety advice
To prevent personal injury or damage to property, halogen lamps may only be operated in suitable luminaires designed with suitable mechanisms (protective shields, grids, etc.) to ensure that in the event of a lamp bursting no parts/shards can escape and that during operation no ultraviolet radiation can escape. There must also be a warning sign to indicate that the lamps give off high levels of heat. Detailed information is available on request.
Photometrical data |
Color temperature |
3200 K |
Dimensions & weight |
Diameter |
26.0 mm |
Length |
110.0 mm |
Light center length (LCL) |
55.0 mm |
Illuminated field |
13.0*15.0 mm² |
Filament diameter |
15.0 mm |
Additional product data |
Base (standard designation) |
GX9.5 |
Capabilities |
Burning position |
s90 |
Certificates & standards |
EEI – Energy Label |
B |
Country specific categorizations |
ANSI code |
FVA |
LIF |
CP/70 |
Order reference |
64745 |
Electrical data |
Nominal wattage |
1000.00 W |
Nominal voltage |
240 V |
|
Reviews