PALMER AUDIO PAN05 TOOLS Microphone Merger 2in to 1out

52.07 incl. GR VAT

In stock

EAN: 4049521049057
Installments calculation
CompareAdd to wishlist Submit Better Price
With the PAN05, two microphone signals can be mixed down to one. Since decoupling occurs via the balanced resistor network, the PAN05 also lets phantom power “pass through“, useful for condenser microphones. However, due to the difference in sound and signal level, mixing dynamic and condenser mics should be avoided. Best results will be achieved […]

 

Read more

With the PAN05, two microphone signals can be mixed down to one. Since decoupling occurs via the balanced resistor network, the PAN05 also lets phantom power “pass through“, useful for condenser microphones. However, due to the difference in sound and signal level, mixing dynamic and condenser mics should be avoided. Best results will be achieved using two identical mics.

SPECIFICATIONS:

  • Input: 2 x XLR/f balanced
  • Nominal impedance: 200 Ω
  • Output 1 x XLR/m balanced
  • Load impedance >200 Ω
  • Symmetrically decoupled through resistors
  • Total ohmic value: 200 ohms
  • Typical attenuation: 6 dB
  • Housing: metal casing 110 x 73 x 42 mm
Weight 0.26 kg

Reviews

There are no reviews yet.

Be the first to review “PALMER AUDIO PAN05 TOOLS Microphone Merger 2in to 1out”

Your email address will not be published. Required fields are marked *

Quick Comparison

PALMER AUDIO PAN05 TOOLS Microphone Merger 2in to 1out removePALMER AUDIO AHMCT8 AUDIO CABLE TESTER removeALPHATON ACT-100 CABLE TESTER removePALMER AUDIO PAN04 PMBL TOOLS Line level Mergebox removeNT-INSTRUMENTS MINI SPL MEASUREMENT MICROPHONE removeNT-INSTRUMENTS MINILYZER analog audio analyzer-audio meter remove
NamePALMER AUDIO PAN05 TOOLS Microphone Merger 2in to 1out removePALMER AUDIO AHMCT8 AUDIO CABLE TESTER removeALPHATON ACT-100 CABLE TESTER removePALMER AUDIO PAN04 PMBL TOOLS Line level Mergebox removeNT-INSTRUMENTS MINI SPL MEASUREMENT MICROPHONE removeNT-INSTRUMENTS MINILYZER analog audio analyzer-audio meter remove
Image
SKUPAN05AHMCT8ACT-100PMBLMINI SPLMINILYZER
Rating
Price 52.07 incl. GR VAT 44.42 incl. GR VAT 297.60 incl. GR VAT 227.94 incl. GR VAT 513.36 incl. GR VAT 1,116.00 incl. GR VAT
Stock

In stock

Only 1 left in stock (can be backordered)

In stock

Available on backorder

Only 5 left in stock

Available on backorder

AvailabilityIn stockOnly 1 left in stock (can be backordered)In stockAvailable on backorderOnly 5 left in stockAvailable on backorder
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description
ContentWith the PAN05, two microphone signals can be mixed down to one. Since decoupling occurs via the balanced resistor network, the PAN05 also lets phantom power "pass through“, useful for condenser microphones. However, due to the difference in sound and signal level, mixing dynamic and condenser mics should be avoided. Best results will be achieved using two identical mics. SPECIFICATIONS:
  • Input: 2 x XLR/f balanced
  • Nominal impedance: 200 Ω
  • Output 1 x XLR/m balanced
  • Load impedance >200 Ω
  • Symmetrically decoupled through resistors
  • Total ohmic value: 200 ohms
  • Typical attenuation: 6 dB
  • Housing: metal casing 110 x 73 x 42 mm
pdfUser's Manual   A stage is only as good as its cables — and the AHMCT 8 sets the record straight. The AHMCT 8 tests the most critical cables on the stage itself and flags up whether they are functioning or not, both visibly via LEDs and audibly via a buzzer. This makes it the perfect tool for engineers — both in the workshop and on stage. The Pro AHMCT is operated simply, intuitively and safely via a single rotary switch on the device. The sturdy metal housing withstands even tough on-stage demands. The standard kit comes with two test probes for carrying out fast and simple continuity tests on various cables or installations.
  • Solid metal housing
  • Powered by a 9-V block battery
  • Tests Speakon, XLR, jack/TRS, cinch and midi/DIN cables
  • Additional continuity tester with measuring probes
  • Optical display and buzzer
Product type Test Equipment
Connectors 6.3 mm Jack , Banana plug , DIN 5-pin , RCA , Speakon, 4-pin , XLR
Controls down , Power On/Off , up , volume
Indicators battery status , LED chain
Operating voltage 9 V block
Acoustic continuity test yes
Test cable yes
Cabinet material sheet steel
Cabinet surface powder coated
Width 105 mm
Depth 145 mm
Weight 0,64 kg

Cable Tester ACT-100

The Alphaton active remote cable tester can be used for testing either normal short
cables or long ones, especially mufticores, wkh connectors not being accessible at
one time. The tester is especially suded for fixed installations where cables can not
be tested with a standard type cable tester or Ohm meter. Either symmetric and
unsymmetric cables can be tested.
“Cold" solderings and junction resistances are displayed by color or luminosity changes
in three color LED Display. The imprinted fault table incorporates alt important fault
conditions, indeed not all possible ones due to their reiatively large number. In case the
display is in a state which cannot be found on the imprinted table, it can be looked up in
the user's manual. In any case, however, the cabie is in aquite unusable state and should
be repaired or replaced.The Alphaton cable tester has a SEND and a REMOTE section.
The REMOTE sectionconsistsof two recessed mounted XLR type male or female connector
and a stereo phone jack at the right hand side of the tester. Additionally, a separate REMOTE
plug is delivered togetherwith the active remote cable tester for testing long cables in fixed
installations.

 

The PMBL is a 2 channel passive line level merge box. Each channel has 2 balanced XLR/f inputs. The input signal is merged via a resistor network to a XLR/m output.The top side input is transformer isolated. Possible applications might be the routing of two mixing desks to one power amp or mixing a stereo signal down to mono. Our transformer technology allows for an unbalanced top side input to be sent out balanced. 

Specifications:

  • Each Channel: Input 1 transformer balanced XLR/f. Symmetrically decoupled through resistors
  • Total ohmic value: 2 K Maximum level for THD

The MiniSPL is the perfect accessory to the Acoustilyzer & Minilyzer for
acoustical measurements.
  The MiniSPL is a battery powered measurement microphone. Together
with the Acoustilyzer or Minilyzer, it forms an acoustical analyzer and integrating
sound level meter. Additionally it may be operated as a stand-alone microphone
e.g. connected to a balanced audio-line, a microphone-input or a sound-card.
  
Product-details
? Battery powered
? Factory-set sensitivity
? No phantom power required
? 1/2" microphone, class 2 acc. IEC 61672
? Omni-directional
? Supplied with mic clamp, wind protection
? Typical frequency response included
MiniSPL together with Acoustilyzer:
? SPL Meter / RTA
? Reverberation Time RT60
? Delay Time
? FFT Analyzer
? Speech Intelligibility STI-PA
MiniSPL together with Minilyzer:
? Measurements: SPL, min./max., Leq
? 1/3rd octave spectrum analyzer

Minilyzer ML1 is the state-of-the-art analog audio meter that fits
into the palm of your hand.
It provides you with a comprehensive set of functions essential
for the analysis of professional audio systems.The powerful Minilyzer
continuously measures the audio signal and displays the desired
results with all complementary information on an illuminated hi-res
graphical LC-Display.
The Minilyzer and the MiniSPL form a comprehensive integrating
sound level meter.
MiniLINK, the USB interface for the Minilyzer allows documentation
and data acquisition of all ML1 functions in conjunction with the easy
to use MiniLINK PC application. MiniLINK supports online data logging
up to several days.
Product-details

Measurement functions:
Level RMS, Relative
Sound Pressure Level
Distortion Analyzer (THD+N), k2 - k5 harmonics
VU & PPM Meter
Speaker Polarity Test(for all speaker types)
Signal Balance Error
Frequency-/Time-Sweep Recording
1/3rd Octave Spectrum RMS & SPL
Scope

Weight0.26 kg0.60 kg0.80 kg0.65 kg0.10 kg0.30 kg
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Weight 0.26 kg
Weight 0.60 kg
Weight 0.80 kg
Weight 0.65 kg
Weight 0.10 kg
Weight 0.30 kg