AKG PERCEPTION 120 Condenser microphone

110.00 incl. GR VAT

In stock

EAN: N/A
Installments calculation
CompareAdd to wishlist Submit Better Price
Live sound Podcasting Home recording Vocals Musical instruments Perception 120 General-purpose cardioid recording microphone Extended frequency response Roadworthy construction Switchable 20 dB preattenuation pad Switchable bass cut filter Designed and engineered by AKG in Vienna, Austria The Perception 120 is a 2/3-inch diaphragm true condenser microphone that offers solid build quality, outstanding performance, and excellent […]

 

Read more

Live sound
Podcasting
Home recording
Vocals
Musical instruments
Perception 120
  • General-purpose cardioid recording microphone
  • Extended frequency response
  • Roadworthy construction
  • Switchable 20 dB preattenuation pad
  • Switchable bass cut filter
  • Designed and engineered by AKG in Vienna, Austria

The Perception 120 is a 2/3-inch diaphragm true condenser microphone that offers solid build quality, outstanding performance, and excellent value. The low-mass diaphragm delivers a clear sound with accurate sonic detail. A switchable 20 dB preattenuation pad and bass cut filter make the Perception 120 an excellent choice for a wide range of recording and live sound applications.

Backed by AKG\’s six decades of experience in making microphones and input from sound engineers around the world, the Perception 120 now brings AKG studio quality to musicians and project studio applications.

Type 2/3\” Diaphragm True Condenser
Polar pattern cardioid
Frequency range 20 to 20,000 Hz
Sensitivity 22 mV/Pa (-33 dBV)
Max. SPL 130/150 dB (0/-20 dB) for 0.5% THD
Equivalent noise level 22 dB-A (IEC 60268-4)
Signal/noise ratio (A-weighted) 72 dB
Preattenuation pad 0 dB, -20 dB
Bass filter 12 dB/octave at 300 Hz
Impedance
Recommended load impedance >= 1,000 ohms
Powering
Power requirement 48 V phantom power to DIN/IEC
Connector 3-pin XLR
Finish metallic blue
Dimensions 53 dia. x 165 mm (2.1 dia. x 6.5 in.)
Net weight 525 g (18.5 oz.)
Shipping weight 955 g (33.7 oz.)
Weight 0.50 kg

Reviews

There are no reviews yet.

Be the first to review “AKG PERCEPTION 120 Condenser microphone”

Your email address will not be published. Required fields are marked *

Quick Comparison

AKG PERCEPTION 120 Condenser microphone removeNEUMANN U-87 Ai Studio Set Condenser studio microphone removeRODE NTK TUBE CONDENSER STUDIO MICROPHONE removeNEUMANN M-150 TUBE Condenser Tube Microphone removeRODE K2 VARIABLE PATTERN CONDENSER VALVE MICROPHONE removeNEUMANN TLM-49 Condenser studio mic remove
NameAKG PERCEPTION 120 Condenser microphone removeNEUMANN U-87 Ai Studio Set Condenser studio microphone removeRODE NTK TUBE CONDENSER STUDIO MICROPHONE removeNEUMANN M-150 TUBE Condenser Tube Microphone removeRODE K2 VARIABLE PATTERN CONDENSER VALVE MICROPHONE removeNEUMANN TLM-49 Condenser studio mic remove
Image
SKUPERCEPTION 120H11NE00046H11RD00012H11NE00026H11RD00006H11NE00032
Rating
Price 110.00 incl. GR VAT 2,849.00 incl. GR VAT 599.00 incl. GR VAT 6,659.00 incl. GR VAT 749.00 incl. GR VAT 1,499.00 incl. GR VAT
Stock

In stock

In stock

In stock

Only 5 left in stock

In stock

In stock

AvailabilityIn stockIn stockIn stockOnly 5 left in stockIn stockIn stock
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description
ContentLive sound
Podcasting Home recording Vocals Musical instruments Perception 120
  • General-purpose cardioid recording microphone
  • Extended frequency response
  • Roadworthy construction
  • Switchable 20 dB preattenuation pad
  • Switchable bass cut filter
  • Designed and engineered by AKG in Vienna, Austria
The Perception 120 is a 2/3-inch diaphragm true condenser microphone that offers solid build quality, outstanding performance, and excellent value. The low-mass diaphragm delivers a clear sound with accurate sonic detail. A switchable 20 dB preattenuation pad and bass cut filter make the Perception 120 an excellent choice for a wide range of recording and live sound applications. Backed by AKG\'s six decades of experience in making microphones and input from sound engineers around the world, the Perception 120 now brings AKG studio quality to musicians and project studio applications.
Type 2/3\" Diaphragm True Condenser
Polar pattern cardioid
Frequency range 20 to 20,000 Hz
Sensitivity 22 mV/Pa (-33 dBV)
Max. SPL 130/150 dB (0/-20 dB) for 0.5% THD
Equivalent noise level 22 dB-A (IEC 60268-4)
Signal/noise ratio (A-weighted) 72 dB
Preattenuation pad 0 dB, -20 dB
Bass filter 12 dB/octave at 300 Hz
Impedance
Recommended load impedance >= 1,000 ohms
Powering
Power requirement 48 V phantom power to DIN/IEC
Connector 3-pin XLR
Finish metallic blue
Dimensions 53 dia. x 165 mm (2.1 dia. x 6.5 in.)
Net weight 525 g (18.5 oz.)
Shipping weight 955 g (33.7 oz.)
Variable large diaphragm microphone
Pressure-gradient transducer with double membrane capsule
The studio microphone classic
Three directional characteristics: omni, cardioid, figure-8
Switchable low frequency roll-off
Switchable 10 dB pre-attenuation

Ideal as main and as support microphone in the most differing recording situations

 

Acoustical operating principle Pressure gradient transducer
Directional pattern Omnidirectional, cardioid, figure-8 plus
Frequency range 20 Hz ... 20 kHz
Sensitivity at 1 kHz into 1 kohm 20/28/22 mV/Pa1)
Rated impedance 200 ohms
Rated load impedance 1 kohms
Equivalent noise level, CCIR2) 26/23/25 dB1)
Equivalent noise level, A-weighted2) 15/12/14 dB-A1)
Signal-to-noise ratio, CCIR2) (rel. 94 dB SPL) 68/71/69 dB1)
Signal-to-noise ratio, A-weighted2) (rel. 94 dB SPL) 79/82/80 dB1)
Maximum SPL for THD 0.5%3) 117 dB (cardioid)
Maximum SPL for THD 0.5% with preattenuation3) 127 dB
Maximum output voltage 390 mV
Dynamic range of the microphone amplifier (A-weighted) 105 dB
Supply voltage (P48, IEC 61938) 48 V ± 4 V
Current consumption (P48, IEC 61938) 0.8 mA
Matching connectors XLR3F
Weight 500 g
Diameter 56 mm
Length 200 mm

 

Rode's new NTK has the quality and warmth demanded from a tube mic.
With the large 1 in. capsule gold-plated membrane and twin triode tubes
(hand graded and selected), Rode is again setting the standard for value.
This is a tube mic designed exclusively for recording professionals who
want what only the best can offer.

Features:
Dynamic range of 47dB
Ultra low noise of only 12dB
Internal capsule shock mounting
Cardioid polar pattern
20Hz - 20kHz frequency response
Includes a power supply, 30 ft. cable, and stand adapter

Technical Description:
Capsule: Externally polarised 1 in. pressure-gradient condenser
Active Electronics: Unity-gain closed-loop impedance converter;
vacuum-tube input with bipolar buffering
Pickup Pattern: Cardioid
Frequency Response: 20Hz - 20kHz (+/-6dB)
Output Impedance: 200 ohms (100 ohms per leg)
Sensitivity: -38dB re 1V/Pa (12mV @ 94dB SPL) +/-1dB
Equivalent Noise: 12dB SPL (A-weighted per IEC268-15) +/-2dB
Maximum Output: > +29dBu (@ 1kHz, 5% THD into 1k (load)
Dynamic Range: > 147dB (A-weighted, per IEC268-15)
Maximum SPL: > 158dB SPL (@ 1kHz, 5% THD into 1k (load)
Signal/Noise Ratio: > 82dB (A-weighted, per IEC268-15)
External power supply: 100-120V/200-240V AC (user selectable)
50Hz/60Hz, 25VA maximum
Packed Weight: 4.53 kg (Mic only 760 gm)

Accessories included:
Power Supply
30 ft (10 m) Multicore Cable
M2 Standmount plus 3/8-5/8 in. Thread Adapter
Optional Extras: SM2 Shockmount

Acoustical operating principlePressure transducer
Directional patternOmnidirectional
Frequency range20 Hz ... 20 kHz
Sensitivity at 1 kHz into 1 kohm20 mV/Pa
Rated impedance50 ohms
Rated load impedance1000 ohms
Equivalent SPL CCIR 468-328 dB
Equivalent SPL DIN/IEC 65115 dB-A
S/N ratio CCIR 468-366 dB
S/N ratio DIN/IEC 65179 dB
Max. SPL (tube characteristic)K
Dynamic range (of the amplifier)K
Maximum output voltage8 dBu
Weight800 g
Diameter78 mm
Length165 mm
* THD of the microphone amplifier at an input voltage which is equivalent to the capsule output voltage at the specified SPL.

K2 - ?It cant be done?? Precision Variable Pattern Dual 1? Condenser Valve Microphone.
 
The R?DE K2 is the result of designing and building 1000?s of valve microphones. The
K2?s HF-1 capsule is the pinnacle of transducer technology. The sound quality combines
modern high-end specifications with the character and subtleties of the legendary 50?s mics.
Infinitely variable control of the K2?s polar patterns provides the freedom and flexibility to
excel in any recording situation. The K2 is another example of R?DE?s commitment to
building quality studio microphones to meet the exacting standards demanded by today?s
professionals.At the 2004 Frankfurt Music Messa, 56 of the most prestgious music industry
magazines voted the K2 the ?Best Studio Microphone of 2004?.

SPECIFICATIONS:
Features:
? New large capsule with gold sputtered diaphragm. ? Ultra low noise.
? Wide dynamic range. ? Class ?A? valve circuitry. ? Hand-selected and
graded 6922 twin-triode valve. ? Dedicated Power Supply. ? High strength
welded and heat-treated steel mesh head. ? Durable satin nickel finish.
? Internal capsule shock mounting. ? High level of RF rejection. ? Supplied
complete with SM2 Shock Mount and RC2 Custom Carry Case.
? Continuously variable polar patterns. From omni, through cardiod to
figure 8, controlled at the power supply.
Operation power:
The K2 is designed to operate from a dedicated power supply (110 - 120 V/220 - 240 V, 50/60 Hz)
Acoustic principle: Externally polarized 25 mm(1?) condenser.
Directional pattern:
Continuously variable multi pattern -Omni, through Cardioid to figure 8.
Frequency range:  20 Hz - 20 kHz
Output impedance:
Valve impedence converter with bipolar output buffer.
Signal noise ratio din iec 651:
 > 81 dB (1kHz relative to 1 Pa; per IEC651,IEC268-15).
Equvalent noise:  10 dBA SPL (per IEC651, IEC268-15).
Maximum spl: 162 dB (@ 1% THD into 1k).
Sensitivity:
 -36 dB re 1 Volt/Pascal (16 mV @ 94 dB SPL) +/- 2 dB.
Power supply voltage:
Dedicated Power Supply(110 - 120 V/220 - 240 V, 50/60 Hz).
Weight:  815 gms
Dimensions width:  208.5 mm
Dimensions depth:  55 mm
Dimensions height:  55 mm
Maximum output voltage:  > +30 dBu (@ 1% THD into 1 k).

Acoustical operating principlePressure gradient transducer
Directional patternCardioid
Frequency range20 Hz ... 20 kHz
Sensitivity at 1 kHz into 1 kohm13 mV/Pa
Rated impedance50 ohms
Rated load impedance1000 ohms
Equivalent noise level, CCIR1)23 dB
Equivalent noise level, A-weighted1)12 dB-A
Signal-to-noise ratio, CCIR1) (rel. 94 dB SPL)71 dB
Signal-to-noise ratio, A-weighted1) (rel. 94 dB SPL)82 dB
Maximum SPL for THD 110 dB
Maximum SPL for THD 129 dB
Maximum output voltage for THD -1 dBu
Dyn. range of the mic. amplifier /A-weighted, 0.5 %2))98 dB
Dyn. range of the mic. amplifier /A-weighted, 5 %2))117 dB
Supply voltage (P48, IEC 61938)48 V ± 4 V
Current consumption (P48, IEC 61938)3.2 mA
Matching connectorXLR 3F
Weight825 g
Diameter78 mm
Length165 mm
1) According to IEC 60268-1; CCIR-weighting according to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS
2) Measured as equivalent el. input signal

Weight0.50 kg2.00 kg2.00 kg0.80 kg2.00 kg0.82 kg
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Weight 0.50 kg
Weight 2.00 kg
Weight 2.00 kg
Weight 0.80 kg
Weight 2.00 kg
Weight 0.82 kg