Content | Live sound
Podcasting
Home recording
Vocals
Musical instruments |
Perception 120 |
|
- General-purpose cardioid recording microphone
- Extended frequency response
- Roadworthy construction
- Switchable 20 dB preattenuation pad
- Switchable bass cut filter
- Designed and engineered by AKG in Vienna, Austria
The Perception 120 is a 2/3-inch diaphragm true condenser microphone that offers solid build quality, outstanding performance, and excellent value. The low-mass diaphragm delivers a clear sound with accurate sonic detail. A switchable 20 dB preattenuation pad and bass cut filter make the Perception 120 an excellent choice for a wide range of recording and live sound applications.
Backed by AKG\'s six decades of experience in making microphones and input from sound engineers around the world, the Perception 120 now brings AKG studio quality to musicians and project studio applications.
Type |
2/3\" Diaphragm True Condenser |
Polar pattern |
cardioid |
Frequency range |
20 to 20,000 Hz |
Sensitivity |
22 mV/Pa (-33 dBV) |
Max. SPL |
130/150 dB (0/-20 dB) for 0.5% THD |
Equivalent noise level |
22 dB-A (IEC 60268-4) |
Signal/noise ratio (A-weighted) |
72 dB |
Preattenuation pad |
0 dB, -20 dB |
Bass filter |
12 dB/octave at 300 Hz |
Impedance |
|
Recommended load impedance |
>= 1,000 ohms |
Powering |
|
Power requirement |
48 V phantom power to DIN/IEC |
Connector |
3-pin XLR |
Finish |
metallic blue |
Dimensions |
53 dia. x 165 mm (2.1 dia. x 6.5 in.) |
Net weight |
525 g (18.5 oz.) |
Shipping weight |
955 g (33.7 oz.) |
| AKG C214 – large 1” diaphragm microphone with cardioid polar pattern, frequency response: 20Hz-20kHz, 20dB pad, requires phantom power (12-52V), XLR connector. Includes clip, case and windshield. Dimensions: 160 x 55mm. Weight: 280g, optional microphone holder SA61
The C214 professional large-diaphragm condenser microphone has been designed as a cost-effective alternative to the high-end C414 family. Like the C414, the C214 offers a supreme one-inch capsule on an integrated suspension to reduce mechanical noise. A switchable 20dB attenuation pad allows recording of loud sources of up to 156dB SPL. A switchable bass-cut filter allows close-up recording with almost no proximity effect.
The C214 captures sound by combining one capsule of the legendary C414 dual-capsule system and the patented AKG Back-Plate Technology, resulting in an outstanding performance close to the famous C414 XLII.
Sonic character of the C414 XLII
for beautifully detailed recording of lead vocals and solo instruments
Outstanding dynamic range and ultralow noise
for close-up recording of high-output sources of up to 156dB SPL
Switchable 20dB attenuator and bass-cut filter
for close-up recording and reduction of proximity effect
Integrated suspension
to reduce mechanical noise and vibration from stage
Roadworthy design
all-metal die-cast body with shock- and scratch-resistant finish |
Acoustical operating principle | Pressure gradient transducer | Directional pattern | Cardioid | Frequency range | 20 Hz ... 20 kHz | Sensitivity at 1 kHz into 1 kohms | 18 mV/Pa | Rated impedance | 50 ohms | Rated load impedance | 1000 ohms | Equivalent SPL CCIR 468-3 | 21 dB | Equivalent SPL DIN/IEC 651 | 10 dB-A | S/N ratio CCIR 468-3 | 73 dB | S/N ratio DIN/IEC 651 | 84 dB | Maximum SPL for THD 0.5% | 140 dB | Maximum output voltage | 13 dBu | Dynamic range of the microphone amplifier DIN/IEC 651 | 130 dB | Supply voltage | 48 V ± 4 V | Current consumption | 3 mA | Matching connectors | XLR 3F | Weight | 480 g | Diameter | 49 mm | Length | 175 mm |
|
Acoustical operating principle | Pressure gradient transducer | Directional pattern | Cardioid | Frequency range | 20 Hz ... 20 kHz | Sensitivity at 1 kHz into 1 kohm | 20 mV/Pa | Rated impedance | 50 ohms | Rated load impedance | 1000 ohms | Equivalent SPL CCIR 468-3 | 24 dB | Equivalent SPL DIN/IEC 651 | 12 dB-A | S/N ratio CCIR 468-3 | 70 dB | S/N ratio DIN/IEC 651 | 82 dB | Maximum SPL | 114 dB for THD | Maximum output voltage | 8 dBu | Dyn. range of the mic. amplifier DIN/IEC 651 | 102 dB for THD | Supply voltage | Power supply N 149 A | Matching connector | Microphone: DIN 8F, Power Supply: XLR 3F | Weight | 460 g | Diameter | 57 mm | Length | 142 mm |
|
Variable large diaphragm microphone | Pressure-gradient transducer with double membrane capsule | The studio microphone classic | Three directional characteristics: omni, cardioid, figure-8 | Switchable low frequency roll-off | Switchable 10 dB pre-attenuation |
Ideal as main and as support microphone in the most differing recording situations
Acoustical operating principle | Pressure gradient transducer | Directional pattern | Omnidirectional, cardioid, figure-8 plus | Frequency range | 20 Hz ... 20 kHz | Sensitivity at 1 kHz into 1 kohm | 20/28/22 mV/Pa1) | Rated impedance | 200 ohms | Rated load impedance | 1 kohms | Equivalent noise level, CCIR2) | 26/23/25 dB1) | Equivalent noise level, A-weighted2) | 15/12/14 dB-A1) | Signal-to-noise ratio, CCIR2) (rel. 94 dB SPL) | 68/71/69 dB1) | Signal-to-noise ratio, A-weighted2) (rel. 94 dB SPL) | 79/82/80 dB1) | Maximum SPL for THD 0.5%3) | 117 dB (cardioid) | Maximum SPL for THD 0.5% with preattenuation3) | 127 dB | Maximum output voltage | 390 mV | Dynamic range of the microphone amplifier (A-weighted) | 105 dB | Supply voltage (P48, IEC 61938) | 48 V ± 4 V | Current consumption (P48, IEC 61938) | 0.8 mA | Matching connectors | XLR3F | Weight | 500 g | Diameter | 56 mm | Length | 200 mm |
| |
Rode's new NTK has the quality and warmth demanded from a tube mic.
With the large 1 in. capsule gold-plated membrane and twin triode tubes
(hand graded and selected), Rode is again setting the standard for value.
This is a tube mic designed exclusively for recording professionals who
want what only the best can offer.
Features:
Dynamic range of 47dB
Ultra low noise of only 12dB
Internal capsule shock mounting
Cardioid polar pattern
20Hz - 20kHz frequency response
Includes a power supply, 30 ft. cable, and stand adapter
Technical Description:
Capsule: Externally polarised 1 in. pressure-gradient condenser
Active Electronics: Unity-gain closed-loop impedance converter;
vacuum-tube input with bipolar buffering
Pickup Pattern: Cardioid
Frequency Response: 20Hz - 20kHz (+/-6dB)
Output Impedance: 200 ohms (100 ohms per leg)
Sensitivity: -38dB re 1V/Pa (12mV @ 94dB SPL) +/-1dB
Equivalent Noise: 12dB SPL (A-weighted per IEC268-15) +/-2dB
Maximum Output: > +29dBu (@ 1kHz, 5% THD into 1k (load)
Dynamic Range: > 147dB (A-weighted, per IEC268-15)
Maximum SPL: > 158dB SPL (@ 1kHz, 5% THD into 1k (load)
Signal/Noise Ratio: > 82dB (A-weighted, per IEC268-15)
External power supply: 100-120V/200-240V AC (user selectable)
50Hz/60Hz, 25VA maximum
Packed Weight: 4.53 kg (Mic only 760 gm)
Accessories included:
Power Supply
30 ft (10 m) Multicore Cable
M2 Standmount plus 3/8-5/8 in. Thread Adapter
Optional Extras: SM2 Shockmount
|