Content | Live sound
Podcasting
Home recording
Vocals
Musical instruments |
Perception 120 |
|
- General-purpose cardioid recording microphone
- Extended frequency response
- Roadworthy construction
- Switchable 20 dB preattenuation pad
- Switchable bass cut filter
- Designed and engineered by AKG in Vienna, Austria
The Perception 120 is a 2/3-inch diaphragm true condenser microphone that offers solid build quality, outstanding performance, and excellent value. The low-mass diaphragm delivers a clear sound with accurate sonic detail. A switchable 20 dB preattenuation pad and bass cut filter make the Perception 120 an excellent choice for a wide range of recording and live sound applications.
Backed by AKG\'s six decades of experience in making microphones and input from sound engineers around the world, the Perception 120 now brings AKG studio quality to musicians and project studio applications.
Type |
2/3\" Diaphragm True Condenser |
Polar pattern |
cardioid |
Frequency range |
20 to 20,000 Hz |
Sensitivity |
22 mV/Pa (-33 dBV) |
Max. SPL |
130/150 dB (0/-20 dB) for 0.5% THD |
Equivalent noise level |
22 dB-A (IEC 60268-4) |
Signal/noise ratio (A-weighted) |
72 dB |
Preattenuation pad |
0 dB, -20 dB |
Bass filter |
12 dB/octave at 300 Hz |
Impedance |
|
Recommended load impedance |
>= 1,000 ohms |
Powering |
|
Power requirement |
48 V phantom power to DIN/IEC |
Connector |
3-pin XLR |
Finish |
metallic blue |
Dimensions |
53 dia. x 165 mm (2.1 dia. x 6.5 in.) |
Net weight |
525 g (18.5 oz.) |
Shipping weight |
955 g (33.7 oz.) |
| Behringer C-1 Studio Condenser Microphone
Behringer C-1 Studio Condenser Microphone
The C-1 Studio Condenser Microphone from Behringer offers a cardioid pickup pattern for maximum sound source separation and feedback rejection. This low noise microphone is suitable for a wide range of recording scenarios, including project, professional, and home studio applications. There is a pressure gradient transducer and a shock-mounted large diaphragm capsule for open, transparent sound with high-quality transient response. It is constructed of a die-cast metal body for durability and features an LED light to indicate when the microphone is receiving phantom power. The C-1 includes a swivel mount and custom case.
- Professional large-diaphragm condenser microphone for unsurpassed audio quality
- Ideal as main and support microphone for studio and live applications
- Exceptionally flat frequency response and ultra-high sound resolution
- Cardioid pickup pattern for outstanding sound source separation and feedback rejection
- Ultra low-noise transformerless FET input circuitry
- LED indicates phantom power operation
- Gold-plated 3-pin XLR output connector for perfect signal transmission
- Ultra-rugged construction with die-cast body
- Swivel stand mount and carrying case included
Operating Principle |
Pressure Gradient |
Capsule |
Condenser |
Diaphragm |
0.63" / 16.0 mm |
Polar Pattern |
Cardioid |
Performance
Frequency Range |
40 Hz to 20 kHz |
Maximum SPL |
136 dB SPL |
Impedance |
100 Ohms |
Load Impedance |
1000 Ohms |
Sensitivity |
-33 dB |
THD |
1% |
Connectivity
Output Connectors (Analog) |
1 x XLR 3-Pin |
Power
Operating Voltage |
36 to 52 V |
Operating Current Consumption |
2.5 µA |
Physical
0.93 lb / 0.42 kg
Dimensions |
ø: 2.13 x L: 7.09" / ø: 54 x L: 180 mm |
Weight |
|
|
Rode's new NTK has the quality and warmth demanded from a tube mic.
With the large 1 in. capsule gold-plated membrane and twin triode tubes
(hand graded and selected), Rode is again setting the standard for value.
This is a tube mic designed exclusively for recording professionals who
want what only the best can offer.
Features:
Dynamic range of 47dB
Ultra low noise of only 12dB
Internal capsule shock mounting
Cardioid polar pattern
20Hz - 20kHz frequency response
Includes a power supply, 30 ft. cable, and stand adapter
Technical Description:
Capsule: Externally polarised 1 in. pressure-gradient condenser
Active Electronics: Unity-gain closed-loop impedance converter;
vacuum-tube input with bipolar buffering
Pickup Pattern: Cardioid
Frequency Response: 20Hz - 20kHz (+/-6dB)
Output Impedance: 200 ohms (100 ohms per leg)
Sensitivity: -38dB re 1V/Pa (12mV @ 94dB SPL) +/-1dB
Equivalent Noise: 12dB SPL (A-weighted per IEC268-15) +/-2dB
Maximum Output: > +29dBu (@ 1kHz, 5% THD into 1k (load)
Dynamic Range: > 147dB (A-weighted, per IEC268-15)
Maximum SPL: > 158dB SPL (@ 1kHz, 5% THD into 1k (load)
Signal/Noise Ratio: > 82dB (A-weighted, per IEC268-15)
External power supply: 100-120V/200-240V AC (user selectable)
50Hz/60Hz, 25VA maximum
Packed Weight: 4.53 kg (Mic only 760 gm)
Accessories included:
Power Supply
30 ft (10 m) Multicore Cable
M2 Standmount plus 3/8-5/8 in. Thread Adapter
Optional Extras: SM2 Shockmount
|
Acoustical operating principle | Pressure transducer | Directional pattern | Omnidirectional | Frequency range | 20 Hz ... 20 kHz | Sensitivity at 1 kHz into 1 kohm | 20 mV/Pa | Rated impedance | 50 ohms | Rated load impedance | 1000 ohms | Equivalent SPL CCIR 468-3 | 28 dB | Equivalent SPL DIN/IEC 651 | 15 dB-A | S/N ratio CCIR 468-3 | 66 dB | S/N ratio DIN/IEC 651 | 79 dB | Max. SPL (tube characteristic) | K | Dynamic range (of the amplifier) | K | Maximum output voltage | 8 dBu | Weight | 800 g | Diameter | 78 mm | Length | 165 mm |
* THD of the microphone amplifier at an input voltage which is equivalent to the capsule output voltage at the specified SPL.
|
Large diaphragm cardioid microphone | Pressure gradient transducer with with one-diaphragm capsule | Transformerless circuitry | Extremely low noise: 7 dB-A | Includes swivel mount | Straightforward handling for homerecording and professional studios |
High-quality professional equipment for limited budgets
Acoustical operating principle | Pressure gradient transducer | Directional pattern | Cardioid | Frequency range | 20 Hz ... 20 kHz | Sensitivity at 1 kHz into 1 kohm | 23 mV/Pa | Rated impedance | 50 ohms | Rated load impedance | 1 kohms | Equivalent noise level, CCIR1) | 17.5 dB | Equivalent noise level, A-weighted1) | 7 dB-A | Signal-to-noise ratio, CCIR1) (rel. 94 dB SPL) | 76.5 dB | Signal-to-noise ratio, A-weighted1) (rel. 94 dB SPL) | 87 dB | Maximum SPL for THD 0.5%2) | 138 dB | Maximum output voltage | 13 dBu | Dynamic range of the microphone amplifier (A-weighted) | 131 dB | Supply voltage (P48, IEC 61938) | 48 V ± 4 V | Current consumption (P48, IEC 61938) | 3 mA | Matching connector | XLR3F | Weight | approx. 450 g | Diameter | 60 mm | Length | 132 mm |
|
|
NT2000 - ?Explore, Control, Create?? Seamlessly Variable Dual 1? Condenser Microphone.
The world's first large diaphragm condenser studio microphone with seamlessly variable Polar
Patterns, Filter and Pad located conveniently on the microphone body. The NT2000?s state of
the art surface-mount electronics combined with the new Australian designed and manufactured
HF1 Capsule, provide extremely low self-noise (7 dBA) and a maximum SPL of 147 dB (157 dB
with pad fully engaged) ensuring exceptional results and the ultimate in recording creativity.
The NT2000 is supplied with the SM2 Shock Mount, together in a durable custom carry case.
SPECIFICATIONS:
Acoustic principle:
Externally polarised 25 mm (1?) dual diaphragm condenser
Directional pattern: Multipattern
Frequency range: 20Hz - 20KHz
Output impedance: 200 ohms
Signal noise ratio din iec 651: 87 dB (1kHz rel 1Pa)
Equvalent noise: 7 dBA SPL (per IEC651, IEC268-15)
Maximum spl:
147 dB (@ 1% THD into 1K ohm) 157dB (@ 1% THD into 1K ohm) with pad set to maximum
Sensitivity:
-36 db re 1 Volt/Pasca (16 mv @94db SPL) +/- 2 dB
Dynamic range din iec 651: 140 dB (per IEC651, IEC268-15)
Power supply voltage: Phantom P48
Weight without battery: 831 gm
Weight with battery: 2.6 kg
|