Price | €99.81 €84.82 incl. GR VAT | €5,442.00 €4,789.00 incl. GR VAT | €7,567.00 €6,659.00 incl. GR VAT | €3,238.00 €2,849.00 incl. GR VAT | €257.99 €209.99 incl. GR VAT | €1,590.00 €1,399.00 incl. GR VAT |
Content |
The C03 features dual large, 19mm ultra thin diaphragm capsules which faithfully reproduce a
variety of sound sources including vocals, acoustic instruments and overhead cymbals to
name a few. And to expand your miking options and recording techniques, the C03 features
three pickup patterns. The Cardioid pattern is great for miking applications where
tight pickup is desired, and with the Omni and Figure 8 patterns you can mic multiple
instruments, capture room sounds and expand your soundfield. The extended frequency
and fast transient response insures an accurate reproduction with linear characteristics
from bottom to top.
Features:
? Large diaphragm, multi-pattern studio condenser microphone.
? Dual 19mm capsules with 3-micron diaphragm.
? Smooth and transparent sound reproduction from bottom to top.
? Super Cardioid, Omni and Figure 8 pickup patterns provide versatility in covering a
variety of miking applications.
? Switchable 10 dB PAD for handling signals with high SPL?s (Sound Pressure Levels).
? Switchable Hi-pass Filter, 12dB per octave at 100 Hz.
? 36-52 Volt Phantom Power operation with Blue LED.
? Internal Shock-mounted capsules.
? Extended frequency response.
? Solid Die Cast construction.
? Swivel Stand Mount and Carry Case included.
Specifications:
Type Condenser Microphone
Polar Pattern Super Cardioid/Fig. 8/Omni
Frequency Response 40~18000 Hz
Sensitivity -40 dBV/pa (10mv/pa)
Rated Impedance 350Ω
Equivalent Noise level 23 dB (A weighted IEC/DIN 651)
Max. SPL 142 dB (THD? 0.5% 1000 Hz)
Dynamic Range 119 dB
Power Supply 48V Phantom Power (IEC 268-
15/DIN 45596)
Current Consumption 7.0 mA
Dimensions ? 54 x 180 mm
Weight 460g
|
Acoustical operating principle | Pressure gradient transducer | Directional pattern | Omnidirectional, wide angle cardioid, cardioid, hypercardioid, figure-8 plus one intermediate position each | Frequency range | 20 Hz ... 20 kHz | Sensitivity at 1 kHz into 1 kohm | 34/47/62 mV/Pa* | Rated impedance | 50 ohms | Rated load impedance | 1000 ohms | Equivalent SPL CCIR 468-3 | 28/25/23 dB* | Equivalent SPL DIN/IEC 651 | 16/13/11 dB-A* | S/N ratio CCIR 468-3 | 66/69/71 dB* | S/N ratio DIN/IEC 651 | 78/81/83 dB* | Typical SPL (tube characteristic) | K | Maximum output voltage | 18 dBu | Dynamic range of the microphone amplifier cardioid DIN/IEC 651 for | 101 (121) dB | Powering | Power supply N 149 | Matching connectors | Microphone DIN 8F, Power supply XLR 3F | Weight | 730 g | Diameter | 70 mm | Length | 201 mm |
* Omnidirectional / cardioid / figure-8
|
Acoustical operating principle | Pressure transducer | Directional pattern | Omnidirectional | Frequency range | 20 Hz ... 20 kHz | Sensitivity at 1 kHz into 1 kohm | 20 mV/Pa | Rated impedance | 50 ohms | Rated load impedance | 1000 ohms | Equivalent SPL CCIR 468-3 | 28 dB | Equivalent SPL DIN/IEC 651 | 15 dB-A | S/N ratio CCIR 468-3 | 66 dB | S/N ratio DIN/IEC 651 | 79 dB | Max. SPL (tube characteristic) | K | Dynamic range (of the amplifier) | K | Maximum output voltage | 8 dBu | Weight | 800 g | Diameter | 78 mm | Length | 165 mm |
* THD of the microphone amplifier at an input voltage which is equivalent to the capsule output voltage at the specified SPL.
|
Variable large diaphragm microphone | Pressure-gradient transducer with double membrane capsule | The studio microphone classic | Three directional characteristics: omni, cardioid, figure-8 | Switchable low frequency roll-off | Switchable 10 dB pre-attenuation |
Ideal as main and as support microphone in the most differing recording situations
Acoustical operating principle | Pressure gradient transducer | Directional pattern | Omnidirectional, cardioid, figure-8 plus | Frequency range | 20 Hz ... 20 kHz | Sensitivity at 1 kHz into 1 kohm | 20/28/22 mV/Pa1) | Rated impedance | 200 ohms | Rated load impedance | 1 kohms | Equivalent noise level, CCIR2) | 26/23/25 dB1) | Equivalent noise level, A-weighted2) | 15/12/14 dB-A1) | Signal-to-noise ratio, CCIR2) (rel. 94 dB SPL) | 68/71/69 dB1) | Signal-to-noise ratio, A-weighted2) (rel. 94 dB SPL) | 79/82/80 dB1) | Maximum SPL for THD 0.5%3) | 117 dB (cardioid) | Maximum SPL for THD 0.5% with preattenuation3) | 127 dB | Maximum output voltage | 390 mV | Dynamic range of the microphone amplifier (A-weighted) | 105 dB | Supply voltage (P48, IEC 61938) | 48 V ± 4 V | Current consumption (P48, IEC 61938) | 0.8 mA | Matching connectors | XLR3F | Weight | 500 g | Diameter | 56 mm | Length | 200 mm |
| |
- Polar pattern: Cardioid
- Switchable -10dB PAD
- Frequency response: 20 - 20,000 Hz
- Max. SPL: 140/150 dB (THD = 0.5%)
- Electrical impedance: 200 Ohm
- Requires phantom power
- Diameter: 53 mm
- Length: 162 mm
- Net weight: 320 g
- Colour: Black
- Incl. shock mount
- Highly affordable AKG large-diaphragm microphone technology
- Cardioid polar pattern for multiplicity of vocal and instrument applications
The earlier model C 3000 has had a large fan club in the project studio and home recording worlds for years. For the new C 3000 B, AKG designed a special 1-inch large-diaphragm transducer that closely approximates the vibration performance of top-class studio microphones, but can be made at much lower cost.
Due to its surface area and special capsule tuning, the C 3000 B large-diaphragm transducer produces an exceptionally pleasing, smooth sound. Unlike in the C 3000, the switchable 10-dB preattenuation pad immediately follows the transducer in the signal path, thus increasing the C 3000 B\'s SPL capability by a true 10 dB. Loud sound sources are therefore no problem.
An acoustically optimized cardioid polar pattern makes the C 3000 B an excellent choice for both recording and live sound applications where high gain before feedback is paramount.
Polar pattern |
cardioid |
Frequency range |
20 to 20,000 Hz |
Sensitivity |
25 mV/Pa (-32 dBV) |
Max. SPL |
140/150 dB (k=0,5%) |
Equivalent noise level (CCIR 468-3) |
25 dB |
Equivalent noise level |
14 dB-A |
Signal/noise ratio (A-weighted) |
80 dB |
Preattenuation pad |
10 dB, switchable |
Bass filter |
6 dB/octave below 500 Hz |
Impedance |
200 ohms |
Recommended load impedance |
>1000 ohms |
Supply voltage |
9 to 52 V phantom power to DIN 45596 |
Current consumption |
|
Connector |
3-pin XLR |
Finish |
silver gray |
Net weight |
320 g / 11.3 oz. |
Shipping weight |
950 g / 2.1 lbs. |
Patent(s) |
Electrostatic transducer (Patent no. AT 395.225, DE 4.103.784, JP 2.815.488) |
|
Acoustical operating principle | Pressure gradient transducer | Directional pattern | Cardioid | Frequency range | 20 Hz ... 20 kHz | Sensitivity at 1 kHz into 1 kohms | 18 mV/Pa | Rated impedance | 50 ohms | Rated load impedance | 1000 ohms | Equivalent SPL CCIR 468-3 | 21 dB | Equivalent SPL DIN/IEC 651 | 10 dB-A | S/N ratio CCIR 468-3 | 73 dB | S/N ratio DIN/IEC 651 | 84 dB | Maximum SPL for THD 0.5% | 140 dB | Maximum output voltage | 13 dBu | Dynamic range of the microphone amplifier DIN/IEC 651 | 130 dB | Supply voltage | 48 V ± 4 V | Current consumption | 3 mA | Matching connectors | XLR 3F | Weight | 480 g | Diameter | 49 mm | Length | 175 mm |
|