Content |
The CM15P is a high-quality gooseneck microphone for any podium application. The condenser element and cardioid pickup pattern provide optimum sound quality for speech and presentations.
Features
* Condenser element
* Cardioid Pickup Pattern
* 15" gooseneck with flexible top and bottom
* Internal Selectable Hi-pass filter
* XLR connector
* Flange-mount included
* Multistage windscreen
* 9-52 Volt Phantom Power Operation
|
- Cardioid instrument microphone with miniature mounting bracket
- High mechanical-noise attenuation
- Including wireless direct adapter for easy use with AKG pocket transmitters
- Detachable microphone cable
- Ideal for miking up accordions and guitar, piano, keyboard, or organ amplifiers
Polar pattern | cardiod | Frequency range | 60 Hz to 20 kHz | Sensitivity | 5 mV/Pa (-46 dBV) | Max. SPL | 130/132 dB SPL (bei k = 1 %/3 %) | Equivalent noise level | 31 dB(A) | Signal/noise ratio (A-weighted) | 63 dB | Impedance | = 2000 ohms | Current consumption | |
|
- Cardioid polar pattern
- 10 m (33 ft.) cable
- 125° pickup angle
- Especially suited for choir recordings
- Integrated spring steel clamp for optimum alignment
The new CHM 99 Condenser Hanging Microphone provides both ease of use and a high level of functionality. There is hardly any more affordable and simpler solution for recording choirs at worship centers. Suspended from the ceiling or a beam, the hanging microphone is aligned and then fixed in the correct position. Now use the spring steel clamp to adjust the correct angle, and off you go!
The CHM 99 is available in white or black.
XY stereo recording
Using two CHM 99 hanging microphones in an XY configuration (coincident pair) is a good way to make stereo recordings, particularly of choirs. However, sound source locations are defined only by intensity differences. Adjusting the angle between the microphones determines the width and depth of the stereo image.
ORTF stereo recording
Developed by the French Broadcasting Authority, this technique differs from the XY technique by recording not only intensity differences, but also delay differences. The capsules are aligned at an angle of precisely 110° and 170 mm / 6.7 in. apart.
Polar pattern Cardioid
Frequency range 70 to 18,000 Hz
Sensitivity 18 mV/PA = -35 dBV re 1 V/Pa
Max. SPL 125 dB (for 1% THD)
Equivalent noise level 73 dB
Impedance =2,000 ohms
Supply voltage 9 to 52 V phantom power to IEC 61938 (DPA adapter integrated)
Powering |
- PA microphone with rugged, all-metal body
- Frequency response optimized for intelligibility
- Long useful life even in tough day-to-day usage
- Frequency response tailored to speech use
Rugged, affordable dynamic cardioid gooseneck microphone for general public address and communications use. The DGN 99 provides a frequency response tailored to speech use for optimum intelligibility as well as good offaxis rejection for high gain before feedback and suppression of unwanted ambient noise. The all-metal body ensures a long useful life for the microphone even in tough day-to-day use.
The DGN 99 E features a built-in XLR connector for quick connection, while the DGN 99 has been designed for permanent (single-hole or screw-on) installation and comes with a 6-ft. 4-in. (2-m) fixed, unterminated cable.
Ticket window, bank counter
Reception desk, restaurant
Houses of worship
|
Polar pattern Cardioid
Frequency range 70 to 18,000 Hz
Max. SPL 125 dB (for 1% THD)
Equivalent noise level 73 dB
Impedance =2,000 ohms
Supply voltage 9 to 52 V phantom power to IEC 61938 (DPA adapter integrated)
Powering |
- Miniature cardioid condenser clamp-on microphone with shock mounted capsule, ideal for miking drums and percussions plus brass
- For use with the B 29 L battery power supply, MPA V L phantom power adapter, or PT 40 or PT 400 transmitters (AKG WMS bodypack transmitters)
- Includes an AKG W 44 Windscreen, an AKG A 518 stabilizer knee, a 5-ft. (1.5-m) plug-in connecting cable with 3-pin mini XLR connector, an A 400 adapter for attaching a PT 40 or PT 400 bodypack transmitter and a protective case
- Integrated gooseneck
- Continuously adjustable vice type clamp
- Type: pre-polarized condenser microphone
- Polar pattern: Cardioid
- Frequency range: 60 Hz to 20,000 Hz
- Sensitivity at 1 kHz: 5 mV/Pa (-46 dBV re 1 V/Pa)
- Impedance: = 200 ohms
- Recommended load impedance: = 2000 ohms
- Max. SPL for 1%/3% THD: 130/132 dB SPL
- Equivalent noise level: 31 dB(A) to DIN 45412
- Cable length / Connector: 1.5 m (5 ft.) / 3-pin mini XLR
- Finish: Matte black
- Size (microphone only): length: 200 mm (7.9 in.), max. width: 47 mm (1.9 in.)
- Net weight (microphone and cable): C 518 M: 220 g (7.8 oz.), C 518 ML: 110 g (3.9 oz.)
- Shipping weight: C 518 M: 450 g (15.9 oz.), C 518 ML: 330 g (11.7 oz.)
|
Reviews