Content |
The MZH 3062 is a metal gooseneck with two flexible sections for use with the ME 34, ME 35 and ME 36 microphone heads. The rugged, matte black gooseneck is fitted with a balanced, floating XLR-3 output, enabling the microphone to be powered from 12 - 48 V phantom power. Length: 600 mm. |
- System Features and Outline
- Operations such as giving speech permission can be done from the operation PC. *Custom design.
- The number of conference units can be set for any of one, two or four persons allowed to talk at a time.
- All speeches during the conference can be recorded clearly.
- Sub audio(Japanese interpretation) is not recorded.
- Threefold choice vote function enables the voting just at the press of a Vote key on each unit. The result can be instantly totalized on the Central unit.
- Speeches can be addressed to audience via sound amplification. * The sub audio output is not amplified
SPECIFICATION:
Power Source | 100-240 V AC, 50/60Hz (supplied from AC adapter (accessory)) | Power Consumption | 72W | Input | MIC: -60 dB*, 600O,unbalanced, phone jackAUX: -20 dB*, 10 kO,unbalanced, phone jack | Output | REC: -20 dB*, 10 kΩ, unbalanced, phone jack, RCA pin jack HEADPHONE: Mini jack | Number of Connectable Chairman/Delegate Units | 64 units | Number of Connectable Infrared Transmitter/Receiver Units | 4 units (up to 16 units by using four Distributors) | Infrared Transmitter/Receiver I/O Terminal | 4 BNC jacks | External Control Terminal | D-sub connector (9 P, male) | LED Indicator | Audio signal receiving indicators 1-4 CH,Data signal receiving indicator, External control priority indicator, External control communication indicator, Power indicator, Battery indicator (flashes when a Chairman/Delegate unit's battery nears complete discharge) | Function Switch | Simultaneous speaker No. setting switch: 1/2/4 Mic-off setting switch: TIME OUT ON/OFF
Speech priority selector switch: A/B/C (A: First-in-first-out priority, B: Last-in-first-out priority, C: Fixed for the first unit, and last-in-first-out for the subsequent units) | Operating Temperature | 0º to+40º | Finish | Panel: Surface-treated steel plate, gray metallic, paint, semi-gloss | Weight | 2.7kg | Accessory | AC adapter (Cord length: 1.8 m DC cord, and 2 m detachable AC cord)…1 | Option | Rack mounting bracket: MB-TS900 | | *0dB=1V |
|
|
- DOT MATRIX DESIGNED VFD DISPLAY
- USB RECORDING(USING USB MEMORY STICK MP3 FILE)
- HIGH FIDELITY 60W MONO CHANNEL AMPLIFIER
- BUILT-IN MONITOR SPREAKER WITH CONTROL VOLUME
- 3 BAND EQUALIZER
- EXTRA MICROPHONE JACK WITH VOLUME
- AUX INPUT AUX OUT LINE INPUT LINE OUT
- CONNECTING: 30 MIC UNIT
- EXPANSION CAPABILITY |
|
|
|
|
Dot MATRIX designed VFD Display |
USB Recording (Using USB Memory stick, MP3 file) |
High fidelity 60W mono channel amplifier |
Built-in monitor speaker with control volume |
3 Band equalizer |
Extra Microphone Jack with Volume |
AUX input, AUX out, LINE input, LINE out |
Connecting : 30 MIC unit |
Expansion capability with IMS-300 (Sub amplifier) |
Power Source : 100~120VAC or 220~240VAC ; 50/60Hz
(supplied AC mains transformer depends on country requirements) |
Weight : 5.8kg / 12.78lb |
Dimensions (W x H x D) : 482 x 44 x 380 mm / 19 x 1.75 x 15in |
※ Specifications and design subject to change without notice. |
|
|
|
|
- System Features and Outline
- Bilingual conference system. Either English interpretation (main audio) or Japanese interpretation (sub audio) is selectable for monitoring.
- Operations such as giving speech permission can be done from the operation PC. *Custom design.
- The number of conference units can be set for any of one, two or four persons allowed to talk at a time.
- All speeches during the conference can be recorded clearly.
- Sub audio(Japanese interpretation) is not recorded.
- Threefold choice vote function enables the voting just at the press of a Vote key on each unit. The result can be instantly totalized on the Central unit.
- Speeches can be addressed to audience via sound amplification. * The sub audio output is not amplified
SPECIFICATION:
Power Source | 7.4 V DC (battery), 9 V DC (AC adapter)
(supplied from BP-900 battery (option) or AD-0910 AC adapter (option)) | Current Consumption | MAX. 270 mA | Wavelength | 870 nm (AM: Brightness modulation) | Modulation Method | Frequency modulation | Carrier Frequency | Transmission: Audio channel 1: 7.35 MHz
Audio channel 2: 8.10 MHz
Audio channel 3: 8.55 MHz
Audio channel 4: 9.15 MHz
Control channel: 6.45 MHz
Reception: Base language channel: 1.95 MHz
Translation language channel: 2.25 MHz | Acceptance Angle | Vertical: 90°, Horizontal: 120° | Emission Angle | Vertical: 90°, Horizontal: 120° | Covering Range | 7 m (radius) | Input | Microphone terminal: Combined type of XLR-4-31 (dedicated for connecting the optional TS-903 or TS-904) | Output | Monitor speaker: 8Ω, 0.2 W
Headphone: Mini jack × 2 | LED Indicator | Speech indicator (flashes when the unit is out of communications range),Voting status indicators 1 -3 (flashes when the unit is out of communication range or when the battery level is low), Power indicator (flashes when the unit is out of communications range or when the battery level is low) | Battery Life | Approx. 10 hours (when the fully-charged BP-900 battery is used with "During Speech" to "Standby" ratio of 1:2) | Operating Temperature | 0º to+40º | Finish | Top panel: ABS resin, gray metallic, paint, semi-gloss | Dimensions | 210(W )×65.9(H )×152(D )mm | Weight | 640g | Option | Lithium-ion battery: BP-900 AC adapter: AD-0910 |
|
- Base Station for up to 200 Microphone Stations
- Intuitive controls
- Superior audio quality
- Voice activation and NOM limitation
- Standard ins and outs for external equipment
The CS 2 Base Station controls up to 200 Microphone Stations and provides automatic NOM (Number of Open Microphones) attenuation. System gain will decrease by approx. 3 dB every time the number of open microphone doubles. The result is a substantially lower risk of feedback even if the number of open microphones varies constantly.
A selectable Voice Activation function turns the microphones on automatically as soon as they are talked into.
The NOM Limitation function allows the number of simultaneously open microphones to be limited to one, two, three, four, or five. This function can be locally disabled on each Microphone Station so a specific microphone, e.g., one mounted on a lectern, will come on every time, no matter how many mics may be open already. |
Power (w/o IEC power cord) for up to 40 microphone units. |