Content | The e 945 is a fully professional super-cardioid vocal microphone which cuts
through the mix and offers a smooth, natural sound. Its warm tonal response
is matched with rugged construction and excellent feedback rejection.
Features
Rugged metal body
Advanced shock-mount design
Consistent on-/off-axis response
Hum compensating coil
Made in Germany
Delivery includes a pouch and a microphone clamp
Delivery Includes
1 e 945
MZQ 800 microphone clamp
Pouch
Technical Data
Pick-up pattern Super-cardioid
Frequency response (microphone) 40.....18000Hz
Sensitivity in free field, no load (1kHz)
2,0mV/Pa bei 1 kHz = -54dB (0 dB = 1V/Pa) = -74 dB (0 dB = 1V/ubar)
Nominal impedance 350 Ohm
Min. terminating impedance 1000 Ohm
Dimensions 47 x 186 mm
Weight 330 g | AKG C411L Ultralight Condenser Microphone
- Ultra-light vibration pickup
- Condenser transducer in sealed enclosure
- Cable with lockable miniature XLR connector
Weighing only 18 grams (0.6 oz.), this ultra-light condenser pickup is ideal for acoustic guitar, mandolin, violin, and most other stringed instruments. The C 411 will give a clear and uncolored sound without changing the balance of the instrument. Attaching the C 411 on or near the bridge or anywhere else on the instrument is easy with the included non-marring, reusable, solventfree adhesive compound.
C 411 L: With mini XLR connector for use with B 29 L battery operated power supply, MPA V L external phantom power adapter, or AKG WMS bodypack transmitters.
Frequency range |
10 to 18,000 Hz |
Max. SPL |
100 dB (for 1% THD) |
Impedance |
200 ohms unbalanced |
Recommended load impedance |
>=1000 ohms |
Supply voltage |
9 to 52 V phantom power to DIN 45596 or battery powering from B 29 L or AKG bodypack transmitter |
Current consumption |
approx. 2.2 mA |
Connector |
C 411 L: 3-pin mini XLR |
Cable |
C 411 L: 1.5 m (5 ft.) |
Finish |
matte black |
Dimensions |
27 x 14 x 9.5 mm / 1.1 x 0.5 x 0.3 in. |
Net weight |
C 411 L: 18 g / 0.7 oz. |
Shipping weight |
C 411 L: 150 g / 5.5 oz. |
|
The e 914 is a high grade condenser microphone for very demanding applications.
Its outstanding sound properties qualify the e 914 for highly sophisticated tasks.
The e 914 is a perfect microphone for ambitious recordings and live performances.
Its main areas of application are acoustic guitars, cymbals, percussion, overhead,
orchestras, grand pianos etc .
Features
Exceptionally lively, clear sound
Three-position sensitivity switch
Three-position bass roll-off/cut-off switch
Very high sound pressure handling capability
Exchangeable microphone capsule
Delivery Includes
e 914 microphone
Microphone clamp
Windscreen
Pouch
User manual
Technical Data
Pick-up pattern cardioid
Frequency response 20...20 000 Hz
Sensitivity in free field, no load (1kHz) 7 mV/Pa
Equivalent noise level 19 dB(A)
Attenuation 0, -10, -20 dB
Max. Sound pressure level (aktiv) 137, 147, 157 dB
Nominal impedance 100 Ohm
Min. terminating impedance 1000 Ohm
Dimensions 24 x 157 mm
Weight 198 g
| NT3 - Versatile & Dependable
Stylish and modern, the NT3 is a studio and location workhorse. With both
48V phantom and internal 9V battery operation, this R?DE is at home anywhere.
Intended for studio, stage and location work, this versatile handheld or stand
mounted microphone incorporates a true externally polarized condenser (hyper-
cardioid polar response) transducer with an internal capsule shock mounting
system, and an ultra-low noise electronic circuit that has a high immunity to R.F.
interference. Incorporating a rugged welded and heat-treated mesh head and all
metal body. The NT3 is supplied in a zip pouch with a windshield, stand mount
and thread adaptor.
SPECIFICATIONS:
Acoustic principle: Externally polarised 19mm (3/4“) condenser
Directional pattern: Hypercardioid
Frequency range: 20Hz-20 kHz
Output impedance: 200?
Signal noise ratio din iec 651: > 77dB (per IEC268-15)
Equvalent noise: 123dB (per IEC268-15)
Power supply voltage: P48, P24, P12 phantom 9V battery
Weight without battery: 371g
Weight with battery: 680g |
The ME 67 is a long gun microphone head designed for use with the K6 and K6P powering modules. A highly directional microphone, it can be used where the microphone must be placed at a distance from the sound source. Matt black, anodised, scratch-resistant finish.
Pick-up pattern : lobar
Sensitivity in free field, no load (1kHz) : 50 mV/Pa +- 2,5 dB
Nominal impedance : 200 Ohm (K6)
Min. terminating impedance : 1000 Ohm (K6)
Equivalent noise level : 10 dB
Dimensions : d 22,5 x 343 mm
Weight : 100 g
|
The e 865 is a fully professional super-cardioid vocal microphone utilising the very best in condenser microphone technology to achieve new standards of quality and sound. The microphone capsule insorporates special blast/pop protiction plate to shield the diaphragm from excessive sound pressure levels. ON/OFF Switch.
- Pick-up pattern : super cardioid
- Sensitivity in free field, no load : (1kHz) 3 mV/Pa
- Max. Sound pressure level (aktiv) : 150 dB
- Nominal impedance : 200 Ohm
- Min. terminating impedance : 1000 Ohm
- Dimensions : d 47 x 193 mm
- Weight : w/o cable 311 g
- Frequency response (microphone) : 40.....20000 Hz
- Phantom powering : 12 - 48 V
|