AKG CS 5 MK 1.25 SYSTEM CABLE

32.11 incl. GR VAT

In stock

EAN: N/A
Installments calculation
CompareAdd to wishlist Submit Better Price
Availability: Available in 1-3 d. Available in 1-3 d. SKU: CS 5 MK 1,25 Category:
Καλώδιο σύνδεσης συνεδριακού 1.25μ

 

Read more

Καλώδιο σύνδεσης συνεδριακού 1.25μ

Weight 0.20 kg

Reviews

There are no reviews yet.

Be the first to review “AKG CS 5 MK 1.25 SYSTEM CABLE”

Your email address will not be published. Required fields are marked *

Quick Comparison

AKG CS 5 MK 1.25 SYSTEM CABLE removeAKG CS-5 DU DELEGATE UNIT SIMPLE removeAKG CS 5 IRT1 INFRARED TRANSMITTER SMALL removeAKG CS 2BU Base Station for up to 200 Microphone Stations removeTOA TS-800 Central Unit removeTOA TS-900 Central Unit remove
NameAKG CS 5 MK 1.25 SYSTEM CABLE removeAKG CS-5 DU DELEGATE UNIT SIMPLE removeAKG CS 5 IRT1 INFRARED TRANSMITTER SMALL removeAKG CS 2BU Base Station for up to 200 Microphone Stations removeTOA TS-800 Central Unit removeTOA TS-900 Central Unit remove
Imagecs_2bu_b Base Station akg
SKUCS 5 MK 1,25CS 5DUCS 5 IRT1CS 2BUTS-800TS-900
Rating
Price 32.11 incl. GR VAT 520.00 incl. GR VAT 2,400.00 incl. GR VAT 894.99 incl. GR VAT 998.00 incl. GR VAT 1,042.00 incl. GR VAT
Stock

In stock

Available on backorder

Available on backorder

In stock

In stock

In stock

AvailabilityIn stockAvailable on backorderAvailable on backorderIn stockIn stockIn stock
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description
Content

Καλώδιο σύνδεσης συνεδριακού 1.25μ

  • Choice of microphones for every kind of system and room acoustics.
  • Ease of use.
  • 3+1 languages selectable for two users.
  • Yes-No-Voting function.

The CS 5 DU is the basic microphone station for use in discussion systems.

Like all other CS 5 microphone stations, the CS 5 DU provides maximum acoustic flexibility. Choose from two goosenecks of different lengths and five microphones with different polar patterns to meet every requirement of any type of conference system.

In addition to the usual PTT key, this microphone station offers two advanced features previously found on more expensive conferencing equipment only: A bank of dip switches allows each headphone output to be assigned independently to either the floor channel or one of three interpreted language channels. The PTT key also provides a simple yes/no voting function.

Gooseneck, capsule and connecting cable are not included.

 

It shall have a built-in microphone and loudspeaker, which allow the forwarding of the voice of the speaker towards the other units of the system. The CS 5 DU shall be capable for 1 step voting from the unit with the help of the speech button.

The CS 5 DU is suitable for taking over maximum 3 interpreted languages and the room voice as well, which may be selected via a set of DIP switches on the bottom of the unit. The unit shall operate for 2 persons simultaneously, with independent adjustable languages for each of the 2 x 3,5mm stereo jack headphone sockets.

 

Infrared radiators providing wireless transmission of up to seven language channels for persons (e.g., observers) listing to a conference without asking for the floor.

The infrared radiators shall connected to the CS 5 BU through 2 BNC connectors and 50 Ohm coaxial cabling and serial concatenation. It shall transmit a  PPM system modulated time-multiplex outputs of the central unit shall drive an arbitrary number of radiators. The CS 5 IRT1 shall have a radiation angle of +/- 22° and a working distance of 300 meters (with 50% down). The CS 5 IRT2 shall have a radiation angle of +/- 22° and a working distance of 500 meters (with 50% down).

As accessories of the infrared radiators the holding frame needed for mounting it to the side wall or the ceiling shall be included. The transmitter shall have a built in switchable power supply with IEC connector.

 

 

  • Base Station for up to 200 Microphone Stations
  • Intuitive controls
  • Superior audio quality
  • Voice activation and NOM limitation
  • Standard ins and outs for external equipment
The CS 2 Base Station controls up to 200 Microphone Stations and provides automatic NOM (Number of Open Microphones) attenuation. System gain will decrease by approx. 3 dB every time the number of open microphone doubles. The result is a substantially lower risk of feedback even if the number of open microphones varies constantly. A selectable Voice Activation function turns the microphones on automatically as soon as they are talked into. The NOM Limitation function allows the number of simultaneously open microphones to be limited to one, two, three, four, or five. This function can be locally disabled on each Microphone Station so a specific microphone, e.g., one mounted on a lectern, will come on every time, no matter how many mics may be open already.
  • System Features and Outline
  • Operations such as giving speech permission can be done from the operation PC. *Custom design.
  • The number of conference units can be set for any of one, two or four persons allowed to talk at a time.
  • All speeches during the conference can be recorded clearly.
  • Sub audio(Japanese interpretation) is not recorded.
  • Threefold choice vote function enables the voting just at the press of a Vote key on each unit. The result can be instantly totalized on the Central unit.
  • Speeches can be addressed to audience via sound amplification. * The sub audio output is not amplified

SPECIFICATION:

Power Source 100-240 V AC, 50/60Hz (supplied from AC adapter (accessory))
Power Consumption 72W
Input MIC: -60 dB*, 600O,unbalanced, phone jackAUX: -20 dB*, 10 kO,unbalanced, phone jack
Output REC: -20 dB*, 10 kΩ, unbalanced, phone jack, RCA pin jack HEADPHONE: Mini jack
Number of Connectable Chairman/Delegate Units 64 units
Number of Connectable Infrared Transmitter/Receiver Units 4 units (up to 16 units by using four Distributors)
Infrared Transmitter/Receiver I/O Terminal 4 BNC jacks
External Control Terminal D-sub connector (9 P, male)
LED Indicator Audio signal receiving indicators 1-4 CH,Data signal receiving indicator, External control priority indicator, External control communication indicator, Power indicator, Battery indicator (flashes when a Chairman/Delegate unit's battery nears complete discharge)
Function Switch Simultaneous speaker No. setting switch: 1/2/4 Mic-off setting switch: TIME OUT ON/OFF
Speech priority selector switch: A/B/C (A: First-in-first-out priority, B: Last-in-first-out priority, C: Fixed for the first unit, and last-in-first-out for the subsequent units)
Operating Temperature 0º to+40º
Finish Panel: Surface-treated steel plate, gray metallic, paint, semi-gloss
Weight 2.7kg
Accessory AC adapter (Cord length: 1.8 m DC cord, and 2 m detachable AC cord)…1
Option Rack mounting bracket: MB-TS900
  *0dB=1V

 

  • System Features and Outline
  • Bilingual conference system. Either English interpretation (main audio) or Japanese interpretation (sub audio) is selectable for monitoring.
  • Operations such as giving speech permission can be done from the operation PC. *Custom design.
  • The number of conference units can be set for any of one, two or four persons allowed to talk at a time.
  • All speeches during the conference can be recorded clearly.
  • Sub audio(Japanese interpretation) is not recorded.
  • Threefold choice vote function enables the voting just at the press of a Vote key on each unit. The result can be instantly totalized on the Central unit.
  • Speeches can be addressed to audience via sound amplification. * The sub audio output is not amplified

SPECIFICATIONS:

Power Source 100-240 V AC, 50/60Hz (supplied from AC adapter (accessory))
Power Consumption 72W
Input MIC: -60 dB*, 600O,unbalanced, phone jackAUX: -20 dB*, 10 kO,unbalanced, phone jack
Output REC: -20 dB*, 10 kΩ, unbalanced, phone jack, RCA pin jack HEADPHONE: Mini jack
Number of Connectable Chairman/Delegate Units 64 units
Number of Connectable Infrared Transmitter/Receiver Units 4 units (up to 16 units by using four Distributors)
Infrared Transmitter/Receiver I/O Terminal 4 BNC jacks
External Control Terminal D-sub connector (9 P, male)
LED Indicator Voting result indicators 1-3 (7-segment LED, double-digit number), Audio signal receiving indicators 1-4 CH, Data signal receiving indicator, External control priority indicator, External control communication indicator, Power indicator, Battery indicator (flashes when a Chairman/Delegate unit's battery nears complete discharge)
Function Switch Simultaneous speaker No. setting switch: 1/2/4 Mic-off setting switch: TIME OUT ON/OFF
Speech priority selector switch: A/B/C (A: First-in-first-out priority, B: Last-in-first-out priority, C: Fixed for the first unit, and last-in-first-out for the subsequent units)
Microphone Mix/Cut Switch (for the Base Language) MIC/CUT (Mix): Chairman/Delegate units + MIC 1+ AUX 1 +AUX 3 → Base Language (Cut): MIC 1 + AUX 1 + AUX 3→ Base Language
Microphone Mix/Cut Switch (for the Translation Language) MIC/CUT (Mix): Chairman/Delegate units + MIC 2 + AUX 2 + AUX 3 → Translation Language (Cut): MIC 2 + AUX 2 + AUX 3→Translation Language
AUX 3 Mixing Select Switch MIC/CUT (Mix): AUX 3 input is relayed to the line output. (Cut): AUX 3 input is not relayed to the line output.
Operating Temperature 0º to+40º
Finish Panel: Surface-treated steel plate, gray metallic, paint, semi-gloss
Weight 2.7kg
Accessory AC adapter (Cord length: 1.8 m DC cord, and 2 m detachable AC cord)…1
Option Rack mounting bracket: MB-TS900
  *0dB=1V

 