LD SYSTEMS D1017SET 7 Piece Drum-Mic-Set

Discontinued

139.99 incl. GR VAT

Out of stock

CompareAdd to wishlist Submit Better Price
LD SYSTEMS 7 Piece Drum-Mic-Set     Set consisting of: 1 x bass drum dynamic microphone 4 x tom/snare drum dynamic microphones 2 x overhead condenser microphones All microphones will be supplied with microphone clips in a hard case. Top cost/performance ratio! Product: Bass-Drum (1x) Overhead (2x) Tom Tom/Snare (4x) Type: Dynamic Back Electret Cond. […]

 

Read more

LD SYSTEMS 7 Piece Drum-Mic-Set

 

 

Set consisting of:
  • 1 x bass drum dynamic microphone
  • 4 x tom/snare drum dynamic microphones
  • 2 x overhead condenser microphones

All microphones will be supplied with microphone clips in a hard case. Top cost/performance ratio!

Product: Bass-Drum (1x) Overhead (2x) Tom Tom/Snare (4x)
Type: Dynamic Back Electret Cond. Dynamic
Polar Pattern: Supercardioid Supercardioid Supercardioid
Frequency response: 50 – 16000 Hz 40 – 18000 Hz 80 – 12000 Hz
Sensitivity: -55 dbV/Pa (1.78mV/Pa) -41 dBV/Pa (8.91 mV/Pa) -51 dbV/Pa (2.82mV/Pa)
Rated impedance: 200 Ω 200 Ω 200 Ω
Min. Load impedance: / 1000 Ω /
Max. SPL: 147 dB 137 dB (THD ≤ 1% 1000 Hz) 150 dB
Signal to Noise Ratio: / 74 dB /
Dynamic Range: / 112 dB /
Power Supply: / 9-48 V Phantom /
Current consumption: / 2 mA /
Connector: 3 pin XLR gold-plated 3 pin XLR gold-plated 3 pin XLR gold-plated
Dimension: ø 46 x 100 mm ø 21 x 200 mm ø 46 x 100 mm
Weight: 260 g 150 g 240 g
Weight 2.40 kg

Reviews

There are no reviews yet.

Be the first to review “LD SYSTEMS D1017SET 7 Piece Drum-Mic-Set”

Your email address will not be published. Required fields are marked *

Quick Comparison

LD SYSTEMS D1017SET 7 Piece Drum-Mic-Set removeSENNHEISER E-602 II Dynamic Microphone for Strings, Kick Drum removeSENNHEISER E-906 SUPER-CARDIOID DYNAMIC MICROPHONE removeSENNHEISER E-904 CARDIOID DYNAMIC INSTRUMENT MICROPHONE removeSHURE BETA-57A - Instrument Microphone 50Hz to 16kHz removeSHURE KSM-137SL - Cardioid Instrument Microphone 20Hz to 20kHz remove
NameLD SYSTEMS D1017SET 7 Piece Drum-Mic-Set removeSENNHEISER E-602 II Dynamic Microphone for Strings, Kick Drum removeSENNHEISER E-906 SUPER-CARDIOID DYNAMIC MICROPHONE removeSENNHEISER E-904 CARDIOID DYNAMIC INSTRUMENT MICROPHONE removeSHURE BETA-57A - Instrument Microphone 50Hz to 16kHz removeSHURE KSM-137SL - Cardioid Instrument Microphone 20Hz to 20kHz remove
ImageSHURE BETA-57A - Instrument Microphone 50Hz to 16kHz
SKUD1017SETH10SE00118H10SE00105H10SE00103BETA57AKSM137/SL
Rating
Price 139.99 incl. GR VAT 148.00 incl. GR VAT 189.00 incl. GR VAT 179.00 incl. GR VAT 175.00 incl. GR VAT 396.80 incl. GR VAT
Stock

Out of stock

In stock

In stock

In stock

Only 1 left in stock (can be backordered)

Available on backorder

AvailabilityOut of stockIn stockIn stockIn stockOnly 1 left in stock (can be backordered)Available on backorder
Add to cart

Read more

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description
Content

LD SYSTEMS 7 Piece Drum-Mic-Set

 

 

Set consisting of:
  • 1 x bass drum dynamic microphone
  • 4 x tom/snare drum dynamic microphones
  • 2 x overhead condenser microphones

All microphones will be supplied with microphone clips in a hard case. Top cost/performance ratio!

Product:Bass-Drum (1x)Overhead (2x)Tom Tom/Snare (4x)
Type:DynamicBack Electret Cond.Dynamic
Polar Pattern:SupercardioidSupercardioidSupercardioid
Frequency response:50 - 16000 Hz40 - 18000 Hz80 - 12000 Hz
Sensitivity:-55 dbV/Pa (1.78mV/Pa)-41 dBV/Pa (8.91 mV/Pa)-51 dbV/Pa (2.82mV/Pa)
Rated impedance:200 Ω200 Ω200 Ω
Min. Load impedance:/1000 Ω/
Max. SPL:147 dB137 dB (THD ≤ 1% 1000 Hz)150 dB
Signal to Noise Ratio:/74 dB/
Dynamic Range:/112 dB/
Power Supply:/9-48 V Phantom/
Current consumption:/2 mA/
Connector:3 pin XLR gold-plated3 pin XLR gold-plated3 pin XLR gold-plated
Dimension:ø 46 x 100 mmø 21 x 200 mmø 46 x 100 mm
Weight:260 g150 g240 g

The E-602 is a cardioid microphone especially suitable for use with bass drums, bass guitar cabs, tubas and other low frequency instruments.


Frequency Response : 20.....16000 Hz
Sensitivity in free field, no load (1kHz) : 1,0 mV/Pa
Min. terminating impedance : 1000 Ohm
Dimensions : d 60 x 153 mm
Weight : w/o cable 550 g

The supercardioid e 906 instrument microphone was especially designed for
guitar amplifiers, but it is also an excellent choice for percussion and brass
instruments.

Features
Lively, full sound
Very fast attack
Flat shape of microphone body perfect for guitar amps 
Three adjustable sound characteristics (bright, normal, smooth)
Hum compensating coil
Rugged metal body
Delivery Includes
e 906 microphone
MZQ 100 clamp
Pouch
User manual

Technical Data
Pick-up pattern  supercardioid 
Frequency response  40...18000 Hz 
Sensitivity in free field, no load (1kHz)  2,2 mV/Pa 
Nominal impedance  350 Ohm 
Min. terminating impedance  1000 Ohm 
Dimensions  55 x 34 x 134 mm 
Weight  140 g 

  • Especially for tom and snare recording
  • Polar pattern: cardioid
  • Frequency range: 40 - 18,000 Hz
  • Impedance: 350 Ω
  • Robust metal chassis
  • Incl. special tom holder
  • Bag included
  • Dimensions: 63 x 41 mm
  • Weight: 125 g
Excellent for acoustic and electric instruments as well as for vocals, the extremely versatile Beta 57A dynamic microphone provides optimal warmth and presence. The Beta 57A maintains a true supercardioid pattern throughout its frequency range. This insures high gain before feedback, maximum isolation from other sound sources, and minimum off-axis tone coloration. A completely new grille design lets you take better advantage of proximity effect. The Beta 57A is an exceptionally versatile microphone. Typical applications include drums, guitar amplifiers, brass, woodwinds and vocals.
  • Tailored frequency response provides drums, guitars, vocals, and horns with studio quality sound
  • Uniform supercardioid pattern for high gain-before-feedback and superior rejection of off-axis sound
  • Hardened steel mesh grille that facilitates use of proximity effect and resists wear and abuse
  • Neodymium magnet for high signal-to-noise ratio output
  • Advanced pneumatic shock mount system that minimizes transmission of mechanical noise and vibration
  • Frequency response: 50 to 16,000 Hz
Suggested Applications Guitar Amp Bass Amp Acoustic Guitar Brass/Saxophone Snare Drums Rack/Floor Toms Congas Woodwinds Lead Vocals

The Shure KSM137 is an end-address condenser microphone with a cardioid polar pattern. Designed for studio use, yet rugged enough for live applications, the KSM137 can withstand extremely high sound pressure levels (SPL). Its low self-noise and extended frequency response make it ideal for recording musical instruments.

Features

  • A highly consistent cardioid polar pattern
  • Ultra-thin, 2.5 micron, 24 karat gold-layered, low mass Mylar? diaphragm for superior transient response
  • Class A, discrete, transformerless preamplifier for transparency, extremely fast transient response, no crossover distortion, and minimal harmonic and intermodulation distortion
  • Premium electronic components, including gold-plated internal and external connectors
  • Subsonic filter eliminates low frequency rumble (less than 17 Hz) caused by mechanical vibration
  • Switchable 15 dB pad for handling extremely high sound pressure levels (SPLs)
  • Three-position switchable pad (0 dB, 15 dB, and 25 dB) for handling extremely high sound pressure levels (SPLs)
  • Three-position switchable low-frequency filter reduces background noise and counteracts proximity effect

Performance Characteristics

  • Extended frequency response
  • Low self noise
  • Exceptional reproduction of low-frequency sounds
  • Can withstand high sound pressure levels (SPL)
  • High output level
  • No crossover distortion
  • Uniform polar response
  • Superior common mode rejection and suppression of radio frequency interference

APPLICATIONS

Some typical applications for the KSM137 are listed below. Microphone use, however, is a matter of personal taste. The KSM137 may be used for a variety of applications other than those listed.

  • Acoustic instruments -- such as piano, guitar, drums, percussion, strings
  • Wind instruments -- brass and woodwind
  • Low frequency instruments -- such as double bass, electric bass, kick drum
  • Overhead miking -- drums or percussion
  • Ensembles -- choral or orchestral
  • Room ambiance pick-up -- guitar amplifier or drums

Both the acoustic environment and microphone placement strongly affect the sound obtained from miking a source. You may need to experiment with microphone placement and room treatments to achieve the best overall sound for each application.

Suggested Applications

Acoustic Guitar
Acoustic Bass
Cymbals
Brass/Woodwinds
Orchestra
Ensemble Vocals
Piano
Strings
Room Ambience
Live Recording

Weight2.40 kg0.55 kg0.32 kg0.30 kg0.50 kg0.50 kg
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Weight 2.40 kg
Weight 0.55 kg
Weight 0.32 kg
Weight 0.30 kg
Weight 0.50 kg
Weight 0.50 kg