LD Systems U 500 GM 530 CC Gooseneck Conference Microphone

101.75 incl. GR VAT

Available on backorder

EAN: 4049521217197
Installments calculation
CompareAdd to wishlist Submit Better Price
Availability: Available in 4-10 d. Available in 4-10 d. SKU: LDU500GM530CC Category:
U 500 Conference Microphone 70 Hz – 18 kHz frequency response 45.6 cm gooseneck with luminous ring 3-pin XLR connector Providing a 70 Hz – 18 kHz frequency response, the U 500 Conference Microphone features a cardioid back-electret condenser capsule on a 45.6 cm gooseneck with luminous ring and 3-pin XLR connector. It requires the […]

 

Read more

U 500 Conference Microphone

70 Hz – 18 kHz frequency response

45.6 cm gooseneck with luminous ring

3-pin XLR connector

Providing a 70 Hz – 18 kHz frequency response, the U 500 Conference Microphone features a cardioid back-electret condenser capsule on a 45.6 cm gooseneck with luminous ring and 3-pin XLR connector. It requires the U 500 microphone base (sold separately, item no. , LDU505CST, LDU506CST, or LDU508CST).

Product type
Microphones


Type
Gooseneck


Colour
Black


Capsule
Back electret condenser


Frequency response
30 – 18.000 Hz


Directivity
Cardioid


Nominal impedance
200 Ohm(s)


Phantom power
11 – 52 V DC


Microphone input
XLR /3-pin, gold plated)


Length
456 mm


Weight
0,15 kg

Weight 0.10 kg

Reviews

There are no reviews yet.

Be the first to review “LD Systems U 500 GM 530 CC Gooseneck Conference Microphone”

Your email address will not be published. Required fields are marked *

Quick Comparison

LD Systems U 500 GM 530 CC Gooseneck Conference Microphone removeAKG C 518 ML Miniature cardioid condenser clamp-on microphone removeSHURE MX-412S-C 12 removeAKG DGN 99E dynamic cardioid Gooseneck Microphone WITH XLR removeAKG CGN 99H/S 38cm Hypercardioid Gooseneck Microphone removeAKG CGN 99 C/L 58cm Hypercardioid Gooseneck Microphone remove
NameLD Systems U 500 GM 530 CC Gooseneck Conference Microphone removeAKG C 518 ML Miniature cardioid condenser clamp-on microphone removeSHURE MX-412S-C 12 removeAKG DGN 99E dynamic cardioid Gooseneck Microphone WITH XLR removeAKG CGN 99H/S 38cm Hypercardioid Gooseneck Microphone removeAKG CGN 99 C/L 58cm Hypercardioid Gooseneck Microphone remove
ImageAKG CGN 99HS 38cm Hypercardioid Gooseneck Microphone-artsoundAKG CGN_99C_L_b
SKULDU500GM530CCC 518 MLMX214SCDGN 99ECGN 99H/SCGN 99C/L
Rating
Price 101.75 incl. GR VAT 253.00 incl. GR VAT 268.00 incl. GR VAT 178.99 incl. GR VAT149.00 incl. GR VAT 149.00 incl. GR VAT
Stock

Available on backorder

Available on backorder

Available on backorder

Available on backorder

Only 2 left in stock (can be backordered)

In stock

AvailabilityAvailable on backorderAvailable on backorderAvailable on backorderAvailable on backorderOnly 2 left in stock (can be backordered)In stock
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description
Content

U 500 Conference Microphone

70 Hz - 18 kHz frequency response

45.6 cm gooseneck with luminous ring

3-pin XLR connector

Providing a 70 Hz - 18 kHz frequency response, the U 500 Conference Microphone features a cardioid back-electret condenser capsule on a 45.6 cm gooseneck with luminous ring and 3-pin XLR connector. It requires the U 500 microphone base (sold separately, item no. , LDU505CST, LDU506CST, or LDU508CST).

Product type Microphones
Type Gooseneck
Colour Black
Capsule Back electret condenser
Frequency response 30 - 18.000 Hz
Directivity Cardioid
Nominal impedance 200 Ohm(s)
Phantom power 11 - 52 V DC
Microphone input XLR /3-pin, gold plated)
Length 456 mm
Weight 0,15 kg
  • Miniature cardioid condenser clamp-on microphone with shock mounted capsule, ideal for miking drums and percussions plus brass
  • For use with the B 29 L battery power supply, MPA V L phantom power adapter, or PT 40 or PT 400 transmitters (AKG WMS bodypack transmitters)
  • Includes an AKG W 44 Windscreen, an AKG A 518 stabilizer knee, a 5-ft. (1.5-m) plug-in connecting cable with 3-pin mini XLR connector, an A 400 adapter for attaching a PT 40 or PT 400 bodypack transmitter and a protective case
  • Integrated gooseneck
  • Continuously adjustable vice type clamp
  • Type: pre-polarized condenser microphone
  • Polar pattern: Cardioid
  • Frequency range: 60 Hz to 20,000 Hz
  • Sensitivity at 1 kHz: 5 mV/Pa (-46 dBV re 1 V/Pa)
  • Impedance: = 200 ohms
  • Recommended load impedance: = 2000 ohms
  • Max. SPL for 1%/3% THD: 130/132 dB SPL
  • Equivalent noise level: 31 dB(A) to DIN 45412
  • Cable length / Connector: 1.5 m (5 ft.) / 3-pin mini XLR
  • Finish: Matte black
  • Size (microphone only): length: 200 mm (7.9 in.), max. width: 47 mm (1.9 in.)
  • Net weight (microphone and cable): C 518 M: 220 g (7.8 oz.), C 518 ML: 110 g (3.9 oz.)
  • Shipping weight: C 518 M: 450 g (15.9 oz.), C 518 ML: 330 g (11.7 oz.)

 

2-inch (30 cm) Gooseneck Condenser Microphone, Cardioid, Attached XLR Preamp, Shock Mount, Flange Mount, Snap-Fit Foam Windscreen, Mute Switch, LED Indicator.

The Microflex Gooseneck microphones bring a whole new meaning to the word flexible. Beyond their fully adjustable goosenecks lies a new level of flexibility the new Microflex interchangeable condenser microphone cartridge. Designed for easy replacement and available in cardioid, supercardioid and omnidirectional polar patterns, the interchangeable cartridges offer wide frequency response and accurate sound reproduction for a broad variety of applications, such as houses of worship, courtrooms and conference centers. Plus, the condenser cartridges fit every model in the new Microflex product line for enhanced convenience and consistent sound.

Features

  • Wide dynamic range and frequency response for accurate sound reproduction across the audio spectrum
  • Interchangeable cartridges provide the right polar pattern for every application
  • Balanced, transformerless output for increased immunity to noise over long cable runs
  • Shock mount that provides over 20 dB isolation from surface vibration noise
  • Locking flange mount for permanently securing microphone to lecterns, pulpits, or conference tables
  • Snap-fit foam windscreen

Specifications

  • Frequency Response: 50Hz to 17kHz
  • Polar Pattern: Cardioid
  • Output Impedance: rated at 150 ohms (180 ohms actual)
  • Maximum SPL: 124.2 dB
  • Signal to Noise Ratio: 66.0 dB
  • Dynamic Range: 96.2 dB
  • Power Requirements: 11 to 52 Vdc phantom, 2.0 mA
  • PA microphone with rugged, all-metal body
  • Frequency response optimized for intelligibility
  • Long useful life even in tough day-to-day usage
  • Frequency response tailored to speech use
Rugged, affordable dynamic cardioid gooseneck microphone for general public address and communications use. The DGN 99 provides a frequency response tailored to speech use for optimum intelligibility as well as good offaxis rejection for high gain before feedback and suppression of unwanted ambient noise. The all-metal body ensures a long useful life for the microphone even in tough day-to-day use.

The DGN 99 E features a built-in XLR connector for quick connection, while the DGN 99 has been designed for permanent (single-hole or screw-on) installation and comes with a 6-ft. 4-in. (2-m) fixed, unterminated cable.

 

Ticket window, bank counter
Reception desk, restaurant
Houses of worship

  • Hypercardioid polar pattern
  • 38 cm  long
  • 95° pickup angle
  • For acoustically difficult environments
  • Connects easily via XLR connector
The hypercardioid polar pattern with its narrow 95° pickup angle is suited best for situations where noise typically occurs from all sides (particularly in worship centers), where people talk into the microphone from a greater distance, or where several talkers are grouped side by side. Two different lengths are available. The .exible joint ensures optimum alignment of the gooseneck to any talker position. Several options are available for installation, i.e., stand, tabletop installation, and lockable. Choosing polar patterns Selecting the correct polar pattern for installed sound is difficult since it depends on a variety of factors. Of course the acoustics of the room play a key role. For highly reverberant rooms such as worship centers, a hypercardioid polar pattern will be the best choice to avoid high levels of unwanted noise. Correct placement of the loudspeakers is also essential. If the speakers project right at the capsule, a hypercardioid will be your best bet. The most difficult task, however, is trying to judge how the talkers will behave. For talkers who are inexperienced or move around a lot, be sure to choose a cardioid polar pattern for reliable pickup; talkers at a greater distance from the mic will be served best by a hypercardioid. The microphone shall be a hypercardioid gooseneck microphone. Its pickup angle shall be 95 degrees; frequency range 50 Hz to 19 kHz; sensitivity 12 mV/Pa; max. SPL 125 dB; electrical impedance
Polar pattern Hypercardioid
Frequency range 50 to 19,000 Hz
Sensitivity 12 mV/PA = -38 dBV re 1 V/Pa
Max. SPL 125 dB (for 1% THD)
Equivalent noise level
Signal/noise ratio (A-weighted) >73 dB
Impedance =2,000 ohms
Supply voltage English: 9 to 52 V phantom power to IEC 61938 (DPA adapter integrated)
Powering
Connector 3-pin male XLR
Finish matte black
Dimensions CGN 99 H/S: 13.5 x 380 mm (0.5 x 15 in.); CGN 99 H/L: 13.5 x 580 mm (0.5 x 23 in.)
Net weight CGN 99 H/S: 480 g (17 oz.); CGN 99 H/L: 500 g (17.7 oz.)
Polar pattern    Cardioid Frequency range    70 to 18,000 Hz Max. SPL    125 dB (for 1% THD) Equivalent noise level    73 dB Impedance    =2,000 ohms Supply voltage    9 to 52 V phantom power to IEC 61938 (DPA adapter integrated) Powering
Weight0.10 kg0.33 kg0.40 kg0.48 kg0.48 kg0.50 kg
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Weight 0.10 kg
Weight 0.33 kg
Weight 0.40 kg
Weight 0.48 kg
Weight 0.48 kg
Weight 0.50 kg