TASCAM TM-95GN Gooseneck Microphone

133.90 incl. GR VAT

In stock

EAN: N/A
Installments calculation
CompareAdd to wishlist Submit Better Price
Availability: Available in 1-3 d. Available in 1-3 d. SKU: TM-95GN Category:
Perfect for Podium or Podcast, the TM-95GN microphone uses a condenser microphone element known for its ability to capture the subtle nuances of speech. Unlike dynamic microphones often used in stage performances, the TM-95GN features a lightweight diaphragm housed in a custom capsule to deliver incredible audio fideity along with rejection of unwanted off-axis sound. […]

 

Read more

Perfect for Podium or Podcast, the TM-95GN microphone uses a condenser microphone element known for its ability to capture the subtle nuances of speech. Unlike dynamic microphones often used in stage performances, the TM-95GN features a lightweight diaphragm housed in a custom capsule to deliver incredible audio fideity along with rejection of unwanted off-axis sound.

TM-95GN SPECIFICATIONS

Model Back-electret condenser microphone
Directivity Cardioid(Unidirectional)
Frequency response 50Hz – 16,000Hz
Output impedance 250Ω +/-30%
Load impedance 100Ω
Sensitivity -39dB +/-3dB (0dB=1V/Pa at 1kHz)
Max. SPL 130dB
Connector 3 pin XLR, Male
Phantom power 48V+/-4V phantom power 
dimensions 132.5 × 457.5 × 140 mm / 5.2 x 18 x 5.5 inch
Weight 970g/2.1 lb
Accessory windscreen, XLR-XLR patch cable

 

Weight 1.00 kg

Reviews

There are no reviews yet.

Be the first to review “TASCAM TM-95GN Gooseneck Microphone”

Your email address will not be published. Required fields are marked *

Quick Comparison

TASCAM TM-95GN Gooseneck Microphone removeSHURE MX-412S-C 12 removeAKG CGN 99H/S 38cm Hypercardioid Gooseneck Microphone removeShure MX418D-C Gooseneck Cardioid Condenser Microphone removeAKG CGN 99 C/L 58cm Hypercardioid Gooseneck Microphone removeAKG GN 30OC MODULE GOOSENECK 30cm LED remove
NameTASCAM TM-95GN Gooseneck Microphone removeSHURE MX-412S-C 12 removeAKG CGN 99H/S 38cm Hypercardioid Gooseneck Microphone removeShure MX418D-C Gooseneck Cardioid Condenser Microphone removeAKG CGN 99 C/L 58cm Hypercardioid Gooseneck Microphone removeAKG GN 30OC MODULE GOOSENECK 30cm LED remove
ImageAKG CGN 99HS 38cm Hypercardioid Gooseneck Microphone-artsoundAKG CGN_99C_L_b
SKUTM-95GNMX214SCCGN 99H/SMX418D-CCGN 99C/LGN 30OC
Rating
Price 133.90 incl. GR VAT 268.00 incl. GR VAT149.00 incl. GR VAT 339.00 incl. GR VAT 149.00 incl. GR VAT 180.00 incl. GR VAT
Stock

In stock

In stock

Only 2 left in stock (can be backordered)

In stock

In stock

Available on backorder

AvailabilityIn stockIn stockOnly 2 left in stock (can be backordered)In stockIn stockAvailable on backorder
Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Add to cart

Description
Content

Perfect for Podium or Podcast, the TM-95GN microphone uses a condenser microphone element known for its ability to capture the subtle nuances of speech. Unlike dynamic microphones often used in stage performances, the TM-95GN features a lightweight diaphragm housed in a custom capsule to deliver incredible audio fideity along with rejection of unwanted off-axis sound.

TM-95GN SPECIFICATIONS
Model Back-electret condenser microphone
Directivity Cardioid(Unidirectional)
Frequency response 50Hz - 16,000Hz
Output impedance 250Ω +/-30%
Load impedance 100Ω
Sensitivity -39dB +/-3dB (0dB=1V/Pa at 1kHz)
Max. SPL 130dB
Connector 3 pin XLR, Male
Phantom power 48V+/-4V phantom power 
dimensions 132.5 × 457.5 × 140 mm / 5.2 x 18 x 5.5 inch
Weight 970g/2.1 lb
Accessory windscreen, XLR-XLR patch cable

 

 

2-inch (30 cm) Gooseneck Condenser Microphone, Cardioid, Attached XLR Preamp, Shock Mount, Flange Mount, Snap-Fit Foam Windscreen, Mute Switch, LED Indicator.

The Microflex Gooseneck microphones bring a whole new meaning to the word flexible. Beyond their fully adjustable goosenecks lies a new level of flexibility the new Microflex interchangeable condenser microphone cartridge. Designed for easy replacement and available in cardioid, supercardioid and omnidirectional polar patterns, the interchangeable cartridges offer wide frequency response and accurate sound reproduction for a broad variety of applications, such as houses of worship, courtrooms and conference centers. Plus, the condenser cartridges fit every model in the new Microflex product line for enhanced convenience and consistent sound.

Features

  • Wide dynamic range and frequency response for accurate sound reproduction across the audio spectrum
  • Interchangeable cartridges provide the right polar pattern for every application
  • Balanced, transformerless output for increased immunity to noise over long cable runs
  • Shock mount that provides over 20 dB isolation from surface vibration noise
  • Locking flange mount for permanently securing microphone to lecterns, pulpits, or conference tables
  • Snap-fit foam windscreen

Specifications

  • Frequency Response: 50Hz to 17kHz
  • Polar Pattern: Cardioid
  • Output Impedance: rated at 150 ohms (180 ohms actual)
  • Maximum SPL: 124.2 dB
  • Signal to Noise Ratio: 66.0 dB
  • Dynamic Range: 96.2 dB
  • Power Requirements: 11 to 52 Vdc phantom, 2.0 mA
  • Hypercardioid polar pattern
  • 38 cm  long
  • 95° pickup angle
  • For acoustically difficult environments
  • Connects easily via XLR connector
The hypercardioid polar pattern with its narrow 95° pickup angle is suited best for situations where noise typically occurs from all sides (particularly in worship centers), where people talk into the microphone from a greater distance, or where several talkers are grouped side by side. Two different lengths are available. The .exible joint ensures optimum alignment of the gooseneck to any talker position. Several options are available for installation, i.e., stand, tabletop installation, and lockable. Choosing polar patterns Selecting the correct polar pattern for installed sound is difficult since it depends on a variety of factors. Of course the acoustics of the room play a key role. For highly reverberant rooms such as worship centers, a hypercardioid polar pattern will be the best choice to avoid high levels of unwanted noise. Correct placement of the loudspeakers is also essential. If the speakers project right at the capsule, a hypercardioid will be your best bet. The most difficult task, however, is trying to judge how the talkers will behave. For talkers who are inexperienced or move around a lot, be sure to choose a cardioid polar pattern for reliable pickup; talkers at a greater distance from the mic will be served best by a hypercardioid. The microphone shall be a hypercardioid gooseneck microphone. Its pickup angle shall be 95 degrees; frequency range 50 Hz to 19 kHz; sensitivity 12 mV/Pa; max. SPL 125 dB; electrical impedance
Polar pattern Hypercardioid
Frequency range 50 to 19,000 Hz
Sensitivity 12 mV/PA = -38 dBV re 1 V/Pa
Max. SPL 125 dB (for 1% THD)
Equivalent noise level
Signal/noise ratio (A-weighted) >73 dB
Impedance =2,000 ohms
Supply voltage English: 9 to 52 V phantom power to IEC 61938 (DPA adapter integrated)
Powering
Connector 3-pin male XLR
Finish matte black
Dimensions CGN 99 H/S: 13.5 x 380 mm (0.5 x 15 in.); CGN 99 H/L: 13.5 x 580 mm (0.5 x 23 in.)
Net weight CGN 99 H/S: 480 g (17 oz.); CGN 99 H/L: 500 g (17.7 oz.)

Shure MX418D-C Gooseneck Cardioid Condenser Microphone

Microflex? Gooseneck microphones bring a whole new meaning to the word flexible
with their fully adjustable gooseneck. Designed for easy replacement and available in
cardioid, supercardioid and omnidirectional polar patterns, the interchangeable cartridges
offer wide frequency response and accurate sound reproduction for a wide variety of applications
such as houses of worship, courtrooms and conference centers. Plus, the condenser cartridges
fit every model in the Microflex product line for enhanced convenience and consistent sound.

Microflex Gooseneck microphones are available in four models with a variety of heights and mounting
styles to choose from. One model includes a silent mute switch with LED indicator, a Shure Microflex
exclusive. And every Microflex Gooseneck features high sensitivity and balanced, transformerless output
for maximum resistance to electromagnetic hum and RF interference, even over long cable runs.

Desktop Base with 10 foot Cable, Logic Functions, Programmable Switch and LED Indicator, Snap-Fit Foam Windscreen

Features:

Wide dynamic range and frequency response for accurate sound reproduction across the audio spectrum
Interchangeable cartridges provide the right polar pattern for every application
Balanced, transformerless output for increased immunity to noise over long cable runs
Shock mount provides over 20 dB isolation from surface vibration noise
Locking flange mount for permanently securing microphone to lecterns, pulpits, or conference tables
Snap-fit foam windscreen
Programmable on/off switch and LED on/off indicator (M412D/MX418D)
New brighter LED improves visibility under strong ambient lighting M412D/MX418D)
Logic input and output terminals for remote control or use with automatic microphone mixers M412D/MX418D)
Supplied shock mount for more than 20 dB isolation from surface transmitted noise (MX412SW/MX418SE)
Supplied threaded flange mount for permanently securing the microphone to a lectern, pulpit, or conference table (MX412SW/MX418SE)

Microphone Specifications:
 
Frequency Response
50 to 17,000 Hz
Output Impedance
180 ohms actual (EIA rated at 150 ohms)
Sensitivity (At 1,000 Hz, open circuit voltage*)
Cardioid: -35.0 dBV/Pa (17.8 mV)
Supercardioid: -33.5 dBV/Pa (21.1 mV)
Omnidirectional: -27.5 dBV/Pa (42.2 mV)
All values -12 dB at 0 gain; *1 Pascal = 94 dB SPL
Maximum SPL (1 kHz at 1% THD, 1 k ohm load)
Cardioid: 124.2 dB
Supercardioid: 122.7 dB
Omnidirectional: 116.7 dB
All values +6 dB at 0 gain
Equivalent Output Noise (A-weighted)
Cardioid: 28.0 dB SPL
Supercardioid: 26.5 dB SPL
Omnidirectional: 20.5 dB SPL
Signal to Noise Ratio (referenced at 94 dB SPL)
Cardioid: 66.0 dB
Supercardioid: 67.5 dB
Omnidirectional: 73.5 dB
Dynamic Range at 1 k ohm load
96.2 dB
100 dB at 0 gain
Common Mode Rejection
45.0 dB minimum
Preamplifier Output Clipping Level (1% THD)
-6.0 dBV (0.5 V)
-12 dBV at 0 gain
Polarity
Positive sound pressure on diaphragm produces positive voltage on pin 2 relative to pin 3 of output connector.
Power Requirements
11 to 52 Vdc phantom, 2.0 mA
Environmental Requirements
Operating Temperature Range: -18 to 57 degrees C (0 to 135 degrees F)
Relative Humidity: 0 to 95%

Polar pattern    Cardioid Frequency range    70 to 18,000 Hz Max. SPL    125 dB (for 1% THD) Equivalent noise level    73 dB Impedance    =2,000 ohms Supply voltage    9 to 52 V phantom power to IEC 61938 (DPA adapter integrated) Powering

AKG GN 30 OC., 12 inch gooseneck for D.A.M.-microphone capsules, 3/8“-connector, programmable indicator LED, incl. 10ft. cable to open-end, black, for installations

Weight1.00 kg0.40 kg0.48 kg0.50 kg0.50 kg0.50 kg
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Weight 1.00 kg
Weight 0.40 kg
Weight 0.48 kg
Weight 0.50 kg
Weight 0.50 kg
Weight 0.50 kg