Content | the t.racks Phase Checker Phase Tester
- For checking acoustic transducers (loudspeakers, microphones) as well as electrical audio accessories
- Consists of a signal generator and a detector
- Generator with acoustic and electrical output
- Output level adjustable
- Detector with acoustic and electrical input (Mic int./Line in / Mic ext switchable)
- LED display
- Power supply (per device): 1x 9 V battery (not included)
|
The MiniSPL is the perfect accessory to the Acoustilyzer & Minilyzer for
acoustical measurements.
The MiniSPL is a battery powered measurement microphone. Together
with the Acoustilyzer or Minilyzer, it forms an acoustical analyzer and integrating
sound level meter. Additionally it may be operated as a stand-alone microphone
e.g. connected to a balanced audio-line, a microphone-input or a sound-card.
Product-details
? Battery powered
? Factory-set sensitivity
? No phantom power required
? 1/2" microphone, class 2 acc. IEC 61672
? Omni-directional
? Supplied with mic clamp, wind protection
? Typical frequency response included
MiniSPL together with Acoustilyzer:
? SPL Meter / RTA
? Reverberation Time RT60
? Delay Time
? FFT Analyzer
? Speech Intelligibility STI-PA
MiniSPL together with Minilyzer:
? Measurements: SPL, min./max., Leq
? 1/3rd octave spectrum analyzer | RS232 Digital Sound Level Meter 8921/8922
- Deluxe super large LCD display w/ affordable price
- Meet IEC60651, type2 class standard
- Unique background noise absorber
- Features w/digital display and analog bar graph
- Professional and rigid design
- Auto / manual ranging ,6 measurement ranges in 10 steps
- Max hold
- Record max / min
- Fast / Slow response mode is selectable
- A /C weighting is selectable
- Easy to calibrate by standard calibrator
- AC/DC analog output
- Tripod mountable
- Backlight function to use in dark area (8922only)
SPECIFICATIONS
Measure range A weight: 30dB~130dB
C weight: 35dB~130dB
Digital display (6 ranges) 30~80, 40~90, 50~100, 60~110, 70-120, 80-130dB
Digital display resolution 0.1dB
Digital updating time 160mS
Quasi-analog bar (6 ranges) 30~80, 40~90, 50~100, 60~110, 70-120, 80-130dB
Quasi-analog bar resolution 1dB
Bar updating time 40mS
Accuracy at 94dB, 1KHz +/-1.5dB
Analog output Microphone AC 0.707Vrms(at full scale); DC 10mV/dB
Dia.6mm electric condenser microphone
Frequency range 31.5Hz~8KHz
Battery life time 30 hours typical
Windscreen LCD YES
size (mm) 42(H)x62(W)
Operating temp. 0~50oC
Operating RH% Humidity
Storage temp. -20~50oC
Storage RH% Humidity
Dimension(mm) Weight 254x77x37
Battery 9V battery x 1pc or 9VDC adaptor
Standard Package Meter/Battery/Manual/carry case
Optional Accessory Computer connection software kit
- DIGITAL DISPLAY WITH ANALOG GRAPH!
- BACKGROUND NOISE ABSORBER !
- BACKLIGHT FOR DARK AREA OPERATION!
- MAX / MIN RECORD, MAX HOLD !
- RS232 INTERFACE !
- MEETS IEC 651, TYPE 2 CLASS !
| Tests XLR, 1/4 in., 1/8 in., TT, RCA and MIDI connectors.
The intelligent, CPU-controlled CT100 accepts virtually any connector type:
XLR, mono and TRS phone (1/4 in., 1/8 in., TT), RCA and MIDI. It shows
which input pin is connected to which output pin. Separate LEDs indicate
proper shield connection and phantom power presence. The CT100 also
offers an installed cable test mode and a continuity check plus a test tone
generator.
Features
3 modes: cable test mode, installed cable test mode, and test tone mode
Accepts XLR, mono and stereo TRS phone (1/4 in., 1/8 in., TT),
RCA and MIDI Connectors
Continuity check
Intermittent detect
Phantom power detect
Grounded shield detect
Test tone generation (1 kHz and 440 Hz)
Battery operation (requires 2 AA alkaline batteries) | GP-300 Infrared Thermometer is specially designed to take the body temperature of a person regardless of room temperature.
Features:
- Precise non-contact measurements
- User selectable ºC or ºF
- Selectable Body and Surface temp
- Set Alarm value for fever warning
- Access to multiple memory values up to 32 records
- Trigger lock
- Automatic Data Hold & Auto power off
- Automatic selection range and Display Resolution 0.1ºC (0.1ºF)
- Backlight LCD display
- Size 149 x 95 x 44 mm
- Weight 172g
- CE certified
Specifications
|
ACOUSTILYZER
The Acoustilyzer AL1 functionality complements and expands the ML1
Minilyzer with a new and comprehensive set of acoustical measurement
functions.
The optimized combination of electrical and acoustical features creates
the perfect all in one tool for sound/systems contractors, installers and
multi-media specialists. The Acoustilyzer AL1 is available as a palm-sized
portable acoustical analyzer or as firmware for Minilyzer owners with optional
available STI-PA measurement functionality.
Required Accessories:
The AL1 requires a measurement microphone for acquiring acoustical signals.
NTI offers the following microphones:
- MiniSPL, class 2 acc. IEC 61672
- M2010, class 1 frequency response (ext. phantom power supply required)
Product Details
Sound Pressure Level: Leq, short-time Leq , LE, Lmin, Lmax,
Real Time Analyzer: 1/1 or 1/3 octave band resolution SPL/LEQ display per
band, max - min display
Zoom FFT: Actual level and Leq, full band up to 0.7Hz resolution
Reverberation Time: RT60 with 1/1 octave band resolution, confidence indicator,
according to ISO3382
Delay Time: Propagation delay between electrical and acoustical signal (built in mic),
resolution: 0.1ms
STI-PA (optional): Single value STI or CIS test result, modulation indices display,
individual band level results, error indicator, amplitude weighting acc. IEC 60268-16
release 2003
Electrical: Level RMS, THD+N, Polarity
Measurement microphone: Required for acquiring acoustical signals, NTI offers MiniSPL
or M2010 measurement microphones
|
Reviews