Content | Replacement stylus 1011 for Dual , D5, D54 Swiss made Gamma diamond and many more phonograph turntables.
Quality aftermarket replacement turntable needle
Specs:
Spherical Diamond Tip needle 0.9 mil
Tracking Force: recommended 3.5 grams
16 or 33 or 45rpm or 78rpm
Stylus Color: White
Swiss Made Gamma
Suitable for
Please check the picture against the stylus you have or get in touch if you need advice. | Stylus 3E
Technical data |
|
Frequency range |
20-20.000 Hz |
Frequency response |
20-18.000 Hz + 2 / - 3 dB |
Tracking ability at 315Hz at recommended tracking force *) |
60 µm |
Compliance, dynamic, lateral |
20 µm/mN |
Stylus type |
Elliptical |
Stylus tip radius |
r/R 8/18 µm |
Equivalent stylus tip mass |
0,5 mg |
Tracking force range |
1,5-2,0 g (15-20 mN) |
Tracking force, recommended |
1,75 g (17,5 mN) |
Tracking angle |
20° |
Stylus colour |
Black |
|
|
Recommended for following cartridges |
OM 3E, OMP 3E |
*) Typical value
|
Stylus 40
Technical data |
| Frequency range | 20-30.000 Hz | Frequency response | 20-30.000 Hz + 2 / - 3 dB | Tracking ability at 315Hz at recommended tracking force *) | 90 µm | Compliance, dynamic, lateral | 25 µm/mN | Stylus type | Nude FG 70 | Stylus tip radius | r/R 5/70 µm | Equivalent stylus tip mass | 0,3 mg | Tracking force range | 1,25-1,75 g (12,5-17,5 mN) | Tracking force, recommended | 1,5 g (15 mN) | Tracking angle | 20° | Stylus colour | Black |
| | Recommended for following cartridges | OM 40, OM 40 GOLD | *) Typical value | Bελόνα Πικάπ για την κεφαλή της Numark CS-1. |
Technical data |
|
Frequency range |
20-29.000 Hz |
Frequency response |
20-20.000 Hz + 2 / -0 dB |
Tracking ability at 315Hz at recommended tracking force *) |
80 µm |
Compliance, dynamic, lateral |
22 µm/mN |
Stylus type |
Nude Fine Line |
Stylus tip radius |
r/R 8/40 µm |
Tracking force range |
1,4-1,7 g (14-17 mN) |
Tracking force, recommended |
1,5 g (15,0 mN) |
Tracking angle |
20° |
Stylus colour |
Bronze |
|
|
Recommended for following cartridges |
2M Bronze |
|
ORTOFON 510MKII βελόνα
- Frequency range20-23.000 Hz
- Frequency response20-20.000 Hz + 2 / - 3 dB
- Tracking ability at 315Hz at recommended tracking force70 µm
- Compliance, dynamic, lateral25 µm/mN
- Stylus typeElliptical
- Stylus tip radiusr/R 8/18 µm
- Equivalent stylus tip mass0,3 mg
- Tracking force range1,25-1,75 g (12,5-17,5 mN)
- Tracking force, recommended1,5 g (15 mN)
- Tracking angle20°
- Stylus colourBlack
-
- Recommended for following cartridgesSeries 510 Mkll, 510, 510 P
|
|
Αξιολογήσεις