Content |
The VX-200PS Power Supply Unit is mounted in the VX-2000PF Power Supply Frame when in use. There are 2 DC output channels per unit. Use the VX-200PS in the number suited to the required total system power.
Power Source | 230 V AC, 50/60 Hz | Power Consumption | 580 W | PS OUT | Rated output: 210 W (29 V, 7.25 A) × 2
Peak output: 400 W × 2
M4 screw terminal, distance between barriers: 11 mm | Operating Temperature | 0℃ to +40℃ | Applicable Frame | VX-2000PF | Finish | Surface-treated steel plate | Dimensions | 135 (W) × 118.2 (H) × 333.8 (D) mm | Weight | 13.2 kg | Accessory | Fuse (T3.15 A L) ……1, Power cable ……1 |
|
Rack system AC/DC power control unit. Σταθεροποιημένη έξοδο DC output με προστασία, ΑC εξόδους: unswitched 1 Group, switched 3 Group, DC εξόδους DC 24V, 5 A, Οθόνη με ένδειξη σε volt ΑC, DC. Διαστάσεις (WxHxD): 482X88X380mm
|
- SYSTEM POWER CONTROL
You can control the power of your system by using this model.
- AC AND DC POWER SUPPLY
You can distribute AC and DC power through the AC outlet and DC terminals on the rear panel.
- USE OF EMERGENCY POWER SUPPLY
For emergency equipment power supply, an extra DC terminal is provided.
- REMOTE CONTROL
You can control the system power by remote control function even though the power switch on front is off.
- AC AND DC VOLT METER
This model uses digital volt meter displays of AC and DC.
- OPERATING MODE DISPLAY
You can easily check the operating mode by LEDs, AC or DC operating and emergency power.
| | | | |
PD-659
|
AC Outlet
|
Switched 2000W ⅹ3
|
Unswitched 700W ⅹ1
|
Remote Control
|
1
|
DC Power Output
|
DC 24V 5A
|
Operation Temperature
|
-10℃~+40℃
|
Power Source
|
100-120VAC or 220-240VAC; 50/60Hz
(Supplied ACmains transformer depends on country requirements)
|
Power Consumption
|
190W
|
Weight(SET)
|
6.2Kg/13.6Ib
|
Dimension(SET)
|
482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in
|
※ Specifications and design subject to change without notice.
|
| | |
|
Πεδίο επέκτασης 20 πλήκτρων του μικορφώνου RM-300MF
The RM-300MF Fireman's Microphone is designed for exclusive use with the VM-3000 Series. It is equipped with an emergency activation key, permitting pre-recorded evacuation and alert announcements to be activated, and microphone announcement to be made in emergency situations. By connecting the RM-320F Fireman's Microphone Extension to the RM-300MF, the number of function keys can be expanded. The zone selection or failure acknowledgment function can be assigned to such function keys.
Power Source
|
24 V DC (operating range: 15 - 40 V DC, supplied from the VM-3000 system)
|
Current Consumption
|
120 mA (RM-300MF), 660 mA (with 3 RM-320F connected)
|
Frequency Response
|
200 Hz - 15 kHz
|
Distortion
|
1 % or less
|
S/N Ratio
|
55 dB or more
|
Microphone
|
Unidirectional dynamic microphone with talk key, compressor (on/off switchable)
|
Volume Control
|
Microphone volume control, Buzzer volume control
|
Connection Cable
|
Main line: Shield CPEV cable (each one pair of Audio line, Data line, Power supply line)
or Category 5 Shielded Twisted-Pair straight cable for LAN (CAT5-STP), M3 screw terminal
|
Maximum Cable Distance
|
Total 800 m (874.89 yd)
|
No. of Connectable RM-320F
|
Max. 3 units
|
Operation
|
Emergency key, Evacuate key, Alert key, Emergency reset key, CPU switch, Reset switch
|
Indicator
|
Power indicator, Emergency indicator, Communication failure indicator, CPU OFF indicator,
Evacuation announcement indicator, Alert announcement indicator,
Emergency reset indicator, Microphone in-use indicator,
Emergency broadcast equipment in-use indicator
|
Operating Temperature
|
-5 ℃ to +45 ℃ (23 ゜F to 113 ゜F)
|
Operating Humidity
|
5 % to 95 %RH (no condensation)
|
Finish
|
ABS resin, blueish gray (PANTONE 538 or its equivalent)
|
Dimensions
|
200 (W) × 215 (H) × 82.5 (D) mm (7.87" × 8.46" × 3.25“)
|
Weight
|
1.1 kg (2.43 lb) (with wall mounting bracket unit)
|
Accessory
|
Wall mounting bracket unit…1, Wall mounting screw…2
|
|
Κονσόλα ανακοινώσεων με πλήκτρα επιλογής μεμονωμένων ή ομάδων μεγαφωνικών ζωνών.
Specification |
| Power Requirement | 24 V DC (12-30 V DC), (Supplied from VM-2120/VM-2240 Amplifier or local power suppy.) | Distortion | Less than 1% | Frequency Response | 100 - 10,000 Hz | Distortion | Less than 1% | Signal-to-Noise Ratio | More than 60 dB | Audio Output | 0 dB*1, 600 Ω, balanced | Microphone | Unidirectional electret condenser microphone, gooseneck type. | Speaker Zone Control | Zones 1-5 (Zones 1-10 with 2 stacked amplifiers) Groups 1-2, and All-Zone Broadcast | Emergency Broadcast | Activation of Emergency Broadcast (pre-recorded announcement*2 or live microphone announcement) by Emergency Switch | Voice Announcement Board Control | Activation of 5 messages*2 | Number of Connectable Units | Up to 4 | Communication System | RS-485 | Volume Control | Microphone volume control | Connection Cable and Connector Category | 5 STP cable, RJ45 connector | Communication Distance | 800 m maximum in total | Finish | ABS resin | Dimensions | 190 (W) × 75.7 (H) × 21.5 (D) mm (Gooseneck microphone excluded) | | *1 0 dB = 1 V
*2 An optional EV-200 Board must be mounted in the VM-2120 or VM-2240 Amplifier. |
|
Attenuator για χρήση σε ξενοδοχεία, σε σύστημα 100V, 330Ω, 7-30W. |
The JBL MTC-300T150 150 Watt Transformer is intended for use with 70V or 100V distributed loudspeaker lines. It is ideally suited for the Control Series 300, especially the 300BB12 Backbox which includes a preinstalled mounting location. |
Αξιολογήσεις