Content |
The VX-200SZ is an audio signal output module of the VX-2000 system with speaker line impedance detection. This module is to be mounted in the VX-2000SF Surveillance Frame and detects speaker line short circuits, open circuits by comparing impedance readings, and ground fault.
Power Source | Supplied from VX-2000SF | Current Consumption | Under 150 mA | Power Amplifier Link | RJ45 female connector for connecting the VP-2064, VP-2122, VP-2241,
VP-2421 Power Amplifier.
Twisted-pair straight cable (TIA/EIA-568A standard) | External Attenuator Control Output | Plug-in screw connector, relay, no-voltage make contact output,
transfer type, withstand voltage: 30 V DC, 250 V AC,
contact current: Under 7 A (DC), under 7 A (AC)
Applicable cable diameter: AWG 24 - AWG 16 | Speaker Output | Plug-in screw connector
Applicable cable diameter: AWG 24 - AWG 16 | Power Amplifier Input | Plug-in screw connector for connecting the VP-2064, VP-2122, VP-2241,
VP-2421 Power Amplifier.
Applicable cable diameter: AWG 24 - AWG 16 | Fault Detection System | Short circuit, open circuit (impedance detection method), ground fault | Finish | Panel: Surface-treated steel plate | Dimensions | 30.5 (W) × 132.6 (H) × 290.3 (D) mm | Weight | 320 g | Accessory | Plug-in screw terminal……1 | Option | Equaliser card: VX-200SE | Applicable Model | VX-2000SF |
|
Μικρόφωνο πυροσβέστη για αποκλειστική χρήση με τη σειρά VM-3000. Διαθέτει πλήκτρο κατάστασης έκτακτης ανάγκης επιτρέποντας την ενεργοποίηση προμαγνητοφωνημένων μηνυμάτων προειδοποίησης και εκκένωσης σύμφωνα με την ΕΝ60849.
Power Source | 24 V DC (operating range: 15 - 40 V DC, supplied from the VM-3000 system) | Current Consumption | 120 mA (RM-300MF), 660 mA (with 3 RM-320F connected) | Frequency Response | 200 Hz - 15 kHz | Distortion | 1 % or less | S/N Ratio | 55 dB or more | Microphone | Unidirectional dynamic microphone with talk key, compressor (on/off switchable) | Volume Control | Microphone volume control, Buzzer volume control | Connection Cable | Main line: Shield CPEV cable (each one pair of Audio line, Data line, Power supply line)
or Category 5 Shielded Twisted-Pair straight cable for LAN (CAT5-STP), M3 screw terminal | Maximum Cable Distance | Total 800 m (874.89 yd) | No. of Connectable RM-320F | Max. 3 units | Operation | Emergency key, Evacuate key, Alert key, Emergency reset key, CPU switch, Reset switch | Indicator | Power indicator, Emergency indicator, Communication failure indicator, CPU OFF indicator,
Evacuation announcement indicator, Alert announcement indicator,
Emergency reset indicator, Microphone in-use indicator,
Emergency broadcast equipment in-use indicator | Operating Temperature | -5 ℃ to +45 ℃ (23 ゜F to 113 ゜F) | Operating Humidity | 5 % to 95 %RH (no condensation) | Finish | ABS resin, blueish gray (PANTONE 538 or its equivalent) | Dimensions | 200 (W) × 215 (H) × 82.5 (D) mm (7.87" × 8.46" × 3.25“) | Weight | 1.1 kg (2.43 lb) (with wall mounting bracket unit) | Accessory | Wall mounting bracket unit …1, Wall mounting screw …2 |
|
The JBL MTC-300T150 150 Watt Transformer is intended for use with 70V or 100V distributed loudspeaker lines. It is ideally suited for the Control Series 300, especially the 300BB12 Backbox which includes a preinstalled mounting location. |
The AT series high quality attenuators features 5 attenuation settings ,,OFF' -18dB,-12db,-6dB,-0dB. An input range from 0.5W to 60W (model dependent), and push-in connectors. Push-in connector allows quick terminal cable connection. Stylishly finished, the AT Series will suit any décor. |
Επιτοίχιος ελεγκτής εντάσεως 12W, 12 θέσεων, με λειτουργία priority.
|
Μονάδα επιλογής 16 μεγαφωνικών γραμμών, τροφοδοσία DC24V
Specification
Brand | InterM | Model | RG-9116 | Features | Speaker line switching; broadcasting status indicators (LED). | Power supply | 24V DC | Dimensions | 482 x 44 x 280 mm | Weight | 3,8 kg | Warranty | 12 months |
|
Αξιολογήσεις