Content |
Info
The CS3 CU chairman unit is a microphone station with two operating modes. In ?priority call? mode, the user can manually mute all connected delegate stations. In ?next in line? mode the CS3 CU automatically activates the next delegate station in the waiting list. The station provides a built in speaker and 2 x 3.5 mm stereo jacks to connect headphones for up to two delegates.
|
- Choice of microphones for every kind of system and room acoustics.
- Ease of use.
- 3+1 languages selectable for two users.
- Yes-No-Voting function.
The CS 5 DU is the basic microphone station for use in discussion systems.
Like all other CS 5 microphone stations, the CS 5 DU provides maximum acoustic flexibility. Choose from two goosenecks of different lengths and five microphones with different polar patterns to meet every requirement of any type of conference system.
In addition to the usual PTT key, this microphone station offers two advanced features previously found on more expensive conferencing equipment only: A bank of dip switches allows each headphone output to be assigned independently to either the floor channel or one of three interpreted language channels. The PTT key also provides a simple yes/no voting function.
Gooseneck, capsule and connecting cable are not included.
It shall have a built-in microphone and loudspeaker, which allow the forwarding of the voice of the speaker towards the other units of the system. The CS 5 DU shall be capable for 1 step voting from the unit with the help of the speech button.
The CS 5 DU is suitable for taking over maximum 3 interpreted languages and the room voice as well, which may be selected via a set of DIP switches on the bottom of the unit. The unit shall operate for 2 persons simultaneously, with independent adjustable languages for each of the 2 x 3,5mm stereo jack headphone sockets.
|
- Digital controller for any size systems
- Ease of use
- Complete with all inputs and outputs needed for complex systems
- Integrated infrared signal output
- Free basic control software included
The CS 5 BU ensures easy, user-friendly control of everything from a small discussion setup to a large conference system. The Base Unit provides all the inputs and outputs needed to manage a complex audio system. It controls 64 audio channels that can be individually programmed and assigned to interpretation channels or NOM limitation.
To ensure maximum reliability, all microphone stations and interpreter stations are „daisy-chained" together and connected back to the Base Unit, forming a closedcircuit digital audio bus. Thus, the entire system will continue operating perfectly, with no interruption, even if one of the bus cables breaks.
To power the system, a CS 5 PS 12 power supply is connected to every twelfth microphone station, ensuring consistent signal levels. Unlike competitive techniques, AKGʼs approach to keeping consistent signal levels throughout the system is uncommonly cost efficient. Every CS 5 Conference System comes complete with a FREE basic control software package so the entire system can be controlled from a computer from day one.
The Base unit shall operate up to 5000 units. As analogue inputs the base unit shall handle an external microphone for easy translating to be routed to channel 1, an ordinary external microphone, telephone in and out with mix minus sum, tape in and out and Line in and out. The infrared modulation shall be included in the base unit, providing the relevant infrared signal on two BNC connectors. Also included in the base unit shall be a USB connector to connect to a PC. A basic software package for participants database, voting and other basic functions shall be included. The unit shall be 1 HU 19” wide in a rack mount housing. A serial port shall be available to enable AMX control.
|
AKG Conference System CS 2 is fully modular and therefore highly flexible, allowing users to create a custom system for any conference application. From microphone capsules to power supplies, designers will find exactly the right components for every type of conference system. Analog control is provided by the Base Station. |
Infrared radiators providing wireless transmission of up to seven language channels for persons (e.g., observers) listing to a conference without asking for the floor.
The infrared radiators shall connected to the CS 5 BU through 2 BNC connectors and 50 Ohm coaxial cabling and serial concatenation. It shall transmit a PPM system modulated time-multiplex outputs of the central unit shall drive an arbitrary number of radiators. The CS 5 IRT1 shall have a radiation angle of +/- 22° and a working distance of 300 meters (with 50% down). The CS 5 IRT2 shall have a radiation angle of +/- 22° and a working distance of 500 meters (with 50% down).
As accessories of the infrared radiators the holding frame needed for mounting it to the side wall or the ceiling shall be included. The transmitter shall have a built in switchable power supply with IEC connector.
|
Supplied ceiling-mounting brackets facilitate installation.
Equipped with power indicator LED.
The IR-510R covers a practical radius of approx. 8 m.
Specification |
| Power Source | 24V DC (Supplied from the optional IR-702T) | Current Consumption | Max.60mA | Infrared Detector | | Wavelength | 870nm | Carrier Frequency | Channel A:3.100MHz/Channel B:3.350MHz | Reception Area | Practical radius of approx. 8 m in a space without any obstacle | Connection Terminal | 75 Ω, BNC jack | Operating Temperature | 0ºC to +40ºC | Operating Humidity | 30% to 85% RH | Finish | Case: Polycarbonate resin, visible light cut filter Base: ABS resin, black | Dimensions | 120 x 71.3 (H) mm | Weight | 205g (unit only) |
|