shielded with BC ?French Braid?, each quad w/26 AWG TC drain wire, color-coded PVC
inner jacket w/overall PVC jacket and 20 AWG TC drain wire.
PHYSICAL CHARACTERISTICS :
CONDUCTOR :
Number of Quads: 4
Total Number of Conductors: 16
AWG: 26
Stranding: 19×38
Conductor Diameter: .020 in.
Conductor Material: BC – Bare Copper
INSULATION :
Insulation Material: PE – Polyethylene
Insulation Diameter: .045 in.
INNER SHIELD :
Inner Shield %Coverage: 95 %
QUAD :
Quad Shield Material Type: French Braid
Quad Shield Material: TC – Tinned Copper
Quad Shield %Coverage: 95 %
INNER SHIELD DRAIN WIRE – QUAD :
Quad Shield Drain Wire AWG: 26
Quad Shield Drain Wire Stranding: 7×38
Quad Shield Drain Wire Conductor Material: TC – Tinned Copper
INNER JACKET :
Inner Jacket Material: PVC – Polyvinyl Chloride
Inner Jacket Diameter: .157 in.
Inner Jacket Insulation Resistance: Brown, Red, Orange, Yellow
Inner Jacket Color Code Chart:
Number Color
1 Brown
2 Red
3 Orange
4 Yellow
QUAD : Quad Inner Jacket Color Code Chart:
Number Color
1 Blue
2 White
3 Blue w/White Stripe
Number Color
4 White w/Blue Stripe
OVERALL CABLING :
Overall Cabling Color Code Chart:
Number Color
1 Brown
2 Red
3 Orange
Number Color
4 Yellow
OUTER SHIELD :
Outer Shield Drain Wire AWG: 20
Outer Shield Drain Wire Stranding: 19×32
Outer Shield Drain Wire Conductor Material: TC – Tinned Copper
OUTER JACKET :
Outer Jacket Material: PVC – Polyvinyl Chloride
OVERALL NOMINAL DIAMETER :
Overall Nominal Diameter: .498 in.
MECHANICAL CHARACTERISTICS :
Operating Temperature Range: -40°C To +60°C
Bulk Cable Weight: 126 lbs/1000 ft.
Max. Recommended Pulling Tension: 178 lbs.
Min. Bend Radius (Install): 5 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE :
APPLICABLE STANDARDS :
EU CE Mark (Y/N): No
EU RoHS Compliant (Y/N): Yes
PLENUM/NON-PLENUM :
Plenum (Y/N): N
ELECTRICAL CHARACTERISTICS :
Nom. Characteristic Impedance: 40 Ω
Nom. Inductance: .21 ?H/ft
Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz: 39.2 pF/ft
Nom. Cap. Between Cond. in a Quad Config. @ 1 KHz: 57.4 pF/ft
Nominal Velocity of Propagation: 66 %
Nom. Conductor DC Resistance @ 20 Deg. C: 36 Ω/1000 ft
Nom. Inner Shield DC Resistance @ 20 Deg. C: 6.8 Ω/1000 ft
Max. Operating Voltage – UL: 100 V RMS
Max. Recommended Current: 1 Amp per conductor @ 25°C
Other Electrical Characteristic 1: 2/c 22 AWG equivalent DCR when connected to a 3-pin XLR.