22 AWG stranded (7×30) .030″ bare copper conductor, foam polyethylene insulation, bare copper braid shield (95% coverage), PVC jacket.       PHYSICAL CHARACTERISTICS :    CONDUCTOR : Number of Coax: 1  Total Number of Conductors: 1  RG Type: 59/U  AWG: 22  Stranding: 7×30  Conductor Diameter: .030 in.  Conductor Material: BC – Bare Copper      INSULATION […]

 

Read more

22 AWG stranded (7×30) .030″ bare copper conductor, foam polyethylene
insulation, bare copper braid shield (95% coverage), PVC jacket.  
 
 
PHYSICAL CHARACTERISTICS : 
 
CONDUCTOR :
Number of Coax: 1 
Total Number of Conductors: 1 
RG Type: 59/U 
AWG: 22 
Stranding: 7×30 
Conductor Diameter: .030 in. 
Conductor Material: BC – Bare Copper 
   
INSULATION :
Insulation Material: FPE – Foam Polyethylene 
Insulation Diameter: .146 in. 
   
OUTER SHIELD :
Outer Shield Type: Braid 
Outer Shield Material: BC – Bare Copper 
Outer Shield %Coverage: 95 % 
   
OUTER JACKET :
Outer Jacket Material: PVC – Polyvinyl Chloride 
   
OVERALL NOMINAL DIAMETER :
Overall Nominal Diameter: .241 in. 
MECHANICAL CHARACTERISTICS : 
 
Operating Temperature Range: -40°C To +80°C 
Non-UL Temperature Rating: 80°C 
Bulk Cable Weight: 33 lbs/1000 ft. 
Max. Recommended Pulling Tension: 65 lbs. 
Min. Bend Radius (Install): 2.5 in. 
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE : 
 
   
APPLICABLE STANDARDS :
NEC/(UL) Specification: CM 
CEC/C(UL) Specification: CM 
AWM Specification: UL Style 1354 (30 V 80°C) 
EU CE Mark (Y/N): Yes 
EU RoHS Compliant (Y/N): Yes 
EU RoHS Compliance Date (mm/dd/yyyy):: 01/01/2004 
   
FLAME TEST :
UL Flame Test: UL1685 UL Loading 
   
SUITABILITY :
Suitability – Indoor: Yes 
Suitability – Outdoor: Yes 
   
PLENUM/NON-PLENUM :
Plenum (Y/N): N 
Plenum Number: 89259 or 82259 
ELECTRICAL CHARACTERISTICS : 
 
Nom. Characteristic Impedance: 75 Ω 
Nom. Inductance: .09 ?H/ft 
Nom. Capacitance Conductor to Shield: 17.3 pF/ft 
Nominal Velocity of Propagation: 78 % 
Nominal Delay: 1.3 ns/ft 
Nom. Conductor DC Resistance @ 20 Deg. C: 15 Ω/1000 ft 
Nominal Outer Shield DC Resistance @ 20°C: 2.6 Ω/1000 ft 
Nom. Attenuation: 
 
Description  Frequency (MHz)  Start Frequency (MHz)  Stop Frequency (MHz)  Nom. Attenuation (dB/100 ft.) 
                        1                                                                                                 .30
                        5                                                                                                 .65
                       10                                                                                                .90
                       50                                                                                                 2.1
                     100                                                                                                 3.0
                     200                                                                                                 4.5
                     400                                                                                                 6.6
                     700                                                                                                 8.9
                     900                                                                                                10.1
                   1000                                                                                                10.9
  
 
Max. Operating Voltage – UL: 300 V RMS 

NOTES :  Notes: For CCTV Applications. 

NOTE: Price per meter

Weight 0.08 kg