Content |
The DBX ZC1 Programmable Volume Control Zone Controller. Provides programmable remote volume control for the DriveRack 260, 220i and the ZonePro 640 and 641.
The DBX ZC1 Zone Controller offers extended utility to the DriveRack and ZonePro families. There are nine Zone Controllers, using analog DC voltage to provide logic control ranging from zone source selection, volume and muting, to program or scene selection and fire safety muting. Wired with readily available and affordable CAT5 cable with universally accepted rj-45 connectors at distances up to 1000 ft, the ZC Zone Controllers offer simple yet elegant solutions to the installer/contractor. The ZC-1 provides programmable remote volume control for the DriveRack 260, 220i and the ZonePro 640 and 641.
The main features of the DBX ZC1 include:
- The ZC-1 provides programmable remote volume control for the DriveRack 260, 220i and the ZonePro 640 and 641
- DIP switches allow identification with connection to the processing device via CAT 5 cable on RJ-45 connectors
- One of nine Zone Controllers options for the DBX ZonePro products
|
- CONVENIENT INSTALLATION AND CONSTRUCTION WITHOUT NEED OF ID SETTING. - ADOPTION OF RS-422 COMMUNICATION METHOD TO SUPPORT A LONG DISTANCE. - REMOTE CONTROL FOR ZONE VOLUME AND SELECTION OF BGM. - INDEPENDENT LOCAL MIC AND BGM BROADCASTING. | Audio Output | 0dB(Balanced) | Audio Input | Paging & RM MIC & LM MIC | -50dB(Balanced) | BGM(Main & Local) | -10dB(Balanced) | Tone Control (100Hz & 10kHz) | Paging MIC | ± 10dB | Audio Output | ± 12dB | Frequency Response | BGM | ± 3dB | MIC | ± 3dB | S / N | BGM | Better than 75dB | MIC | Batter than 65dB | T.H.D. | BGM | Less than 0.05% | MIC | Less than 0.05% | Priority Control | Paging MIC > DRP > RM1> RM2 > RM3 > RM4 > LM-8000 > Main BGM | Phantom Power | DC 24V | Serial Interface | Communication Speed | 9600bps | Communication Distance | Maximum 300m(UTP CAT%) | Operation Temperature | -10℃ ~ +40℃ | Power Source | 100-120VAC or 220-240VAC; 50/60Hz (Supplied AC mains transformer depends on country requirements) | Weight(SET) | 130g / 0.28lb | Dimensions(SET) | 70(W) x 114(H) x 52(D)mm 2.8(W) x 4.5(H) x 2.0(D)in | ※ Specifications and design subject to change without notice. |
|
RM-200M - Five/ten zone console for VM-2120/2240 amplfiers
The RM-200M Remote Microphone that allows announcements to be made to any speaker zone and emergency announcements to all zones on a system with the VM-2120/2240 system management amplifiers.
These announcements can be made live or pre-recorded announcements
can be activated. The remote microphone is connected by cable to the
RM-210 Remote Microphone Extension unit.
SPECIFICATIONS:
Power Requirement | 24 V DC (12-30 V DC), (Supplied from VM-2120/VM-2240 Amplifier or local power suppy.) | Distortion | Less than 1% | Frequency Response | 100 - 10,000 Hz | Distortion | Less than 1% | Signal-to-Noise Ratio | More than 60 dB | Audio Output | 0 dB*1, 600 O, balanced | Microphone | Unidirectional electret condenser microphone, gooseneck type. | Speaker Zone Control | Zones 1-5 (Zones 1-10 with 2 stacked amplifiers) Groups 1-2, and All-Zone Broadcast | Emergency Broadcast | Activation of Emergency Broadcast (pre-recorded announcement*2 or live microphone announcement) by Emergency Switch | Voice Announcement Board Control | Activation of 5 messages*2 | Number of Connectable Units | Up to 4 | Communication System | RS-485 | Volume Control | Microphone volume control | Connection Cable and Connector Category | 5 STP cable, RJ45 connector | Communication Distance | 800 m maximum in total | Finish | ABS resin | Dimensions | 190 (W) × 75.7 (H) × 21.5 (D) mm (Gooseneck microphone excluded) |
| *1 0 dB = 1 V
*2 An optional EV-200 Board must be mounted in the VM-2120 or VM-2240 Amplifier. |
|
The AT series high quality attenuators features 5 attenuation settings ,,OFF'' -18dB,-12db,-6dB,-0dB. An input range from 0.5W to 60W (model dependent), and push-in connectors. Push-in connector allows quick terminal cable connection. Stylishly finished, the AT Series will suit any décor. |
- PRIORITY CONTROL It controls the priority of emergency, timer, remote1, remote2, main(normal). - AUTO FIRE SENSOR The fire alarm will be given automatically to the designated areas by detecting fire sensor input. - SPEAKER SWITCHING ON EMERGENCY OR NORMAL(MAIN) You can control the speaker relay on emergency or normal(main) mode by using the speaker switch on front panel. - DISPLAY STATUS You can easily check the priority status. - 2 AND 3 WIRE SPEAKER LINE SYSTEM You can control the speaker line on the 2 wire system or 3 wire system. - EXTENSION FUNCTION You can easily expand by connecting additional ECS-616.
ECS-616 | Priority Control | Emergency >Timer > Remote1 > Remote2 > Main | Link in/ out Interface | RS-422(19200bps,Data 8bits,Stop 1bit, Non Parity bit, Start1bit) | Link in/ out interface Distance | 1.2 km | Operation Temperature | -10 °C ~+ 40 °C | Power Source | 24V DC | Power Consumption | 900mA | Weight | 4.8Kg/10.6Ib | Dimensions( W x H x D) | 482(W)x 88(H) x 380(D) mm / 19(W)x 3.5(H)x 15(D)in | ※ Specifications and design subject to change without notice. |
|
| - CONVENIENT INSTALLATION AND CONSTRUCTION WITHOUT NEED OF ID SETTING. - SELECTION OF VARIOUS CHIME BROADCASTINGS FOR MIC BROADCASTING (PRE/POST). - CONVENIENT PRIORITY BROADCASTING. - ADOPTION OF OUTPUT SIGNAL LEVEL DISPLAY. - ADOPTION OF RS-422 COMMUNICATION METHOD TO SUPPORT A LONG DISTANCE. | | | | | | Audio Output | 0dB(Balanced) | Audio Input | Paging & RM MIC & LM MIC | -50dB(Balanced) | BGM(Main & Local) | -10dB(Balanced) | Tone Control (100Hz & 10kHz) | Paging MIC | ± 10dB | Audio Output | ± 12dB | Frequency Response | BGM | ± 3dB | MIC | ± 3dB | S / N | BGM | Better than 75dB | MIC | Batter than 65dB | T.H.D. | BGM | Less than 0.05% | MIC | Less than 0.05% | Priority Control | Paging MIC > DRP > RM1> RM2 > RM3 > RM4 > LM-8000 > Main BGM | Phantom Power | DC 24V | Serial Interface | Communication Speed | 9600bps | Communication Distance | Maximum 300m(UTP CAT%) | Operation Temperature | -10℃ ~ +40℃ | Power Source | 100-120VAC or 220-240VAC; 50/60Hz (Supplied AC mains transformer depends on country requirements) | Weight(SET) | 1.5kg / 3.2lb | Dimensions(SET) | 200(W) x 70(H) x 206(D)mm 7.9(W) x 2.8(H) x 8.1(D)in | ※ Specifications and design subject to change without notice. | | | |
|