Content |
ΡΥΘΜΙΣΤΗΣ ΕΝΤΑΣΕΩΣ VOLUME ( FADER )
ΙΣΧΥΣ: 6 W
ΧΡΩΜΑ: ΑΣΠΡΟ
ΔΙΑΣΤΑΣΕΙΣ: 8,5 x 8,5 x 6 cm |
RM-200M - Five/ten zone console for VM-2120/2240 amplfiers
The RM-200M Remote Microphone that allows announcements to be made to any speaker zone and emergency announcements to all zones on a system with the VM-2120/2240 system management amplifiers.
These announcements can be made live or pre-recorded announcements
can be activated. The remote microphone is connected by cable to the
RM-210 Remote Microphone Extension unit.
SPECIFICATIONS:
Power Requirement | 24 V DC (12-30 V DC), (Supplied from VM-2120/VM-2240 Amplifier or local power suppy.) | Distortion | Less than 1% | Frequency Response | 100 - 10,000 Hz | Distortion | Less than 1% | Signal-to-Noise Ratio | More than 60 dB | Audio Output | 0 dB*1, 600 O, balanced | Microphone | Unidirectional electret condenser microphone, gooseneck type. | Speaker Zone Control | Zones 1-5 (Zones 1-10 with 2 stacked amplifiers) Groups 1-2, and All-Zone Broadcast | Emergency Broadcast | Activation of Emergency Broadcast (pre-recorded announcement*2 or live microphone announcement) by Emergency Switch | Voice Announcement Board Control | Activation of 5 messages*2 | Number of Connectable Units | Up to 4 | Communication System | RS-485 | Volume Control | Microphone volume control | Connection Cable and Connector Category | 5 STP cable, RJ45 connector | Communication Distance | 800 m maximum in total | Finish | ABS resin | Dimensions | 190 (W) × 75.7 (H) × 21.5 (D) mm (Gooseneck microphone excluded) |
| *1 0 dB = 1 V
*2 An optional EV-200 Board must be mounted in the VM-2120 or VM-2240 Amplifier. |
|
The JBL MTC-300T150 150 Watt Transformer is intended for use with 70V or 100V distributed loudspeaker lines. It is ideally suited for the Control Series 300, especially the 300BB12 Backbox which includes a preinstalled mounting location. |
The RM-300MF Fireman's Microphone is designed for exclusive use with the VM-3000 Series. It is equipped with an emergency activation key, permitting pre-recorded evacuation and alert announcements to be activated, and microphone announcement to be made in emergency situations. By connecting the RM-320F Fireman's Microphone Extension to the RM-300MF, the number of function keys can be expanded. The zone selection or failure acknowledgment function can be assigned to such function keys.
Power Source | 24 V DC (operating range: 15 - 40 V DC, supplied from the VM-3000 system) | Current Consumption | 120 mA (RM-300MF), 660 mA (with 3 RM-320F connected) | Frequency Response | 200 Hz - 15 kHz | Distortion | 1 % or less | S/N Ratio | 55 dB or more | Microphone | Unidirectional dynamic microphone with talk key, compressor (on/off switchable) | Volume Control | Microphone volume control, Buzzer volume control | Connection Cable | Main line: Shield CPEV cable (each one pair of Audio line, Data line, Power supply line)
or Category 5 Shielded Twisted-Pair straight cable for LAN (CAT5-STP), M3 screw terminal | Maximum Cable Distance | Total 800 m (874.89 yd) | No. of Connectable RM-320F | Max. 3 units | Operation | Emergency key, Evacuate key, Alert key, Emergency reset key, CPU switch, Reset switch | Indicator | Power indicator, Emergency indicator, Communication failure indicator, CPU OFF indicator,
Evacuation announcement indicator, Alert announcement indicator,
Emergency reset indicator, Microphone in-use indicator,
Emergency broadcast equipment in-use indicator | Operating Temperature | -5 ℃ to +45 ℃ (23 ゜F to 113 ゜F) | Operating Humidity | 5 % to 95 %RH (no condensation) | Finish | ABS resin, blueish gray (PANTONE 538 or its equivalent) | Dimensions | 200 (W) × 215 (H) × 82.5 (D) mm (7.87" × 8.46" × 3.25“) | Weight | 1.1 kg (2.43 lb) (with wall mounting bracket unit) | Accessory | Wall mounting bracket unit …1, Wall mounting screw …2 |
|
| - SYSTEM POWER CONTROL You can control the power of your system by using this model. - AC AND DC POWER SUPPLY You can distribute AC and DC power through the AC outlet and DC terminals on the rear panel. - USE OF EMERGENCY POWER SUPPLY For emergency equipment power supply, an extra DC terminal is provided. - REMOTE CONTROL You can control the system power by remote control function even though the power switch on front is off. - AC AND DC VOLT METER This model uses digital volt meter displays of AC and DC. - OPERATING MODE DISPLAY You can easily check the operating mode by LEDs, AC or DC operating and emergency power. | | | | | PD-659 | AC Outlet | Switched 2000W ⅹ3 | Unswitched 700W ⅹ1 | Remote Control | 1 | DC Power Output | DC 24V 5A | Operation Temperature | -10℃~+40℃ | Power Source | 100-120VAC or 220-240VAC; 50/60Hz (Supplied ACmains transformer depends on country requirements) | Power Consumption | 190W | Weight(SET) | 6.2Kg/13.6Ib | Dimension(SET) | 482(W) x 88(H) x 380(D)mm/19(W) x 3.5(H) x 15(D)in | ※ Specifications and design subject to change without notice. | | | |
|
This model should be used with concerning equipment (emergency switcher-our model ES-9116, matrix-our model PX-9116, emergency panel-our model EP-9216). Specification Brand | InterM | Model | RG-9116 | Features | Speaker line switching; broadcasting status indicators (LED). | Power supply | 24V DC | Dimensions | 482 x 44 x 280 mm | Weight | 3,8 kg | Warranty | 12 months |
|